Door Relays, Isolators, Locks, & Bolts
Showing Results for Door Relays, Isolators, Locks, & Bolts
-
HES
SKU: 4902-01-630
HES 4902-01-630 Short Box Strike with Dust Box
Short box strike with dust protection for HES electric systems
- Flush-mount box strike fits standard 1-3/4" frames with no frame modification.
- Integrated dust box shields keeper cavity from debris, extending indoor service life.
- Pre-drilled .57" plate with four mounting holes reduces field layout time on install.
$29.00 $14.99 Save $14.01 -
HES
SKU: 4902-02-630
HES 4902-02-630 Electric Strike
Heavy-duty electric strike with fail-safe/fail-secure modes for wood and metal frames
- Supports fail-safe and fail-secure modes via wiring—no field modification required.
- 24 VDC solenoid sustains continuous duty cycles with minimal thermal drift.
- Includes .57" mounting plate for standard wood and metal frame prep—no machining needed.
$24.62 $13.99 Save $10.63 -
HES
SKU: 5000
HES 5000 Strike Body Only PoE Electric Strike
PoE electric strike body for custom access control installations
- PoE (802.3af) powered at ~13W—no transformer or dedicated wiring needed
- Strike body only; mount to non-standard frames without field fabrication
- 24VDC electromagnetic solenoid rated for high-traffic commercial duty cycles
$226.00 $114.99 Save $111.01 -
HES
SKU: 5000-12/24D-630
HES 5000-12/24D-630 Dual-Voltage Electric Strike
Fail-secure strike with 12/24V DC selectable power for access control
- Dual-voltage operation (12V or 24V DC) eliminates SKU duplication across sites
- Fail-secure design locks on power loss or control signal failure for high-security areas
- Standard door frame form factor integrates with proximity readers and access panels
$226.00 $114.99 Save $111.01 -
HES
SKU: 5000C-630-LBM
HES 5000C-630-LBM Electric Strike with Latch Bolt Monitor
630-pound electric strike with integrated latch bolt monitoring
- Built-in latch bolt monitor eliminates need for separate sensors
- 630-pound holding force rated for high-traffic commercial doors
- Dry contact and supervised circuit output to access control panels
$358.00 $180.99 Save $177.01 -
HES
SKU: 5000C-LBM
HES 5000C-LBM Complete Electric Strike
Complete electric strike, dual voltage 12V/24V, drop-in ready
- Operates on 12V or 24V DC without modification or jumper changes
- Fully integrated assembly cuts installation time vs. field-assembled strikes
- Compatible with standard access control wiring protocols, no custom adapters
$358.00 $180.99 Save $177.01 -
HES
SKU: 501-613E
HES 501-613E Electric Strike Faceplate Bronze
Bronze replacement faceplate for HES 5000/5200 series electric strikes
- Drop-in replacement for HES 5000/5200 series strikes reduces installation time.
- Bronze powder coat finish resists corrosion for consistent appearance across door hardware.
- ANSI metal jamb compatibility ensures fit with standard cylindrical lockset deployments.
$56.00 $55.99 Save $0.01 -
HES
SKU: 501A-613E
HES 501A-613E Electric Strike Faceplate Bronze Power
Bronze Power faceplate for HES 5000/5200 electric strike systems
- Bronze Power finish matches architectural hardware for consistent aesthetics across strike points.
- Compatible with HES 5000/5200 series, cylindrical locksets, and spring latches in aluminum frames.
- Supports retrofit and new-construction deployments in offices, institutions, and government facilities.
$61.00 $60.99 Save $0.01 -
HES
SKU: 503-606
HES 503-606 Satin Brass Faceplate for Cylindrical Locksets
Satin brass faceplate for cylindrical locksets on aluminum frames
- Universal mounting tabs fit standard aluminum frame installations
- Compatible with cylindrical locksets and spring latch mechanisms
- Satin brass finish for professional appearance in commercial spaces
$96.00 $95.99 Save $0.01 -
HES
SKU: 5200-630
HES 5200-630 Universal Electric Strike
Universal mortise electric strike for retrofit and new installations, fail-safe or fail-secure
- Works with standard mortise lock preps; no frame modification needed for retrofit
- Configurable fail-safe or fail-secure modes to match your security and code requirements
- Supports single and double doors on 12VDC or 24VDC panel power
$241.00 $121.99 Save $119.01 -
HES
SKU: 5200C-630
HES 5200C-630 Complete PACS for Latchbolt Locks
Complete electric strike + control system for latchbolt locks
- Factory pre-matched components eliminate integration mismatches on site
- Latchbolt-specific strike design with proper throw and release timing
- All hardware included for multi-door deployments; 12VDC powered
$269.00 $135.99 Save $133.01 -
HES
SKU: 5200C-LBM
HES 5200C-LBM Complete PAC Latchbolt Lock Package
Pre-assembled latchbolt PAC with power supply and mounting hardware
- Complete 12VDC power distribution and mechanical mounting in one package
- Standard latchbolt lock compatibility eliminates custom component sourcing
- Ready-to-deploy indoor commercial access control with minimal setup time
$376.00 $189.99 Save $186.01 -
HES
SKU: 5200C-LBSM
HES 5200C-LBSM Electric Latchbolt Strike
Fail-safe electric latchbolt strike for standard access control systems
- Electromagnetic retention locks latch when de-energized; no battery backup needed
- Standard form factor installs in existing door frames without modification
- Works with typical access control circuit voltages; integrates into current infrastructure
$398.00 $200.99 Save $197.01 -
HES
SKU: 5204-1
HES 5204-1 Stackable Lip Extension
Stackable lip extension for HES strikes; adjusts depth without frame cuts
- Stack multiple units to accommodate variable jamb thickness on retrofit jobs
- Eliminates frame modification, reducing installation time and labor costs
- Compatible with HES electric strike systems across standard door frames
$67.00 $53.99 Save $13.01 -
HES
SKU: 600D
HES 600D Double Magnetic Lock 600 lbs
Dual magnetic lock 600 lbs per door, single control circuit
- 600 lbs holding force on each door for high-traffic commercial entries
- One relay output controls both doors simultaneously with synchronized unlock
- 12/24 VDC dual voltage compatible with standard access control panels
$392.00 $216.99 Save $175.01 -
HES
SKU: 600DDURO
HES 600DDURO Heavy-Duty Electromagnetic Lock
Industrial electromagnetic lock for single/double doors, 12VDC fail-safe
- Fail-safe design unlocks on power loss, satisfying life-safety egress code requirements.
- 12VDC input works with standard access control power supplies and battery backup systems.
- Supports single and double door configurations with no frame modification on retrofits.
$488.00 $269.99 Save $218.01
Door Relays, Isolators, Locks, & Bolts
Door relays, isolators, electric locks, and bolt hardware connect access control systems to physical door security. Proper selection ensures reliable operation, electrical protection, and compliance with life-safety requirements in commercial deployments.
Plan Your Deployment
- Fail-safe vs fail-secure lock configuration
- Door type and mounting surface compatibility
- Voltage requirements and power supply capacity
- Relay isolation to protect controller boards
- Local fire and building code compliance
Door Relays, Isolators, Locks, & Bolts — Engineering-Grade Door Hardware for Commercial Deployments
This category covers 338 working models of door relays, isolators, locks, & bolts sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.
What to Look For
Fail-safe versus fail-secure determines what happens during power loss. Fail-safe locks unlock on power loss (used on egress doors where life safety dominates); fail-secure locks remain locked (used on storage, server rooms, and exterior doors where security dominates). Code typically mandates fail-safe on stairwell and egress doors. Confirm with the AHJ before specifying — misapplied lock mode is a common code violation.
Strike, mortise, magnetic lock, and electrified panic hardware each have distinct installation, current draw, and code implications. Electric strikes work with most mechanical locksets and are easiest to retrofit. Magnetic locks (maglocks) provide high holding force on glass and wood doors but require dedicated REX and panic-bar interfaces for egress compliance. Verify the door's existing prep before choosing.
Power draw and inrush current dictate power supply sizing. A 5-door system with 1A peak per lock can exceed an undersized 12VDC supply at simultaneous lock-down events. Account for accessories — REX motion sensors, door-position switches, electrified levers — when sizing the supply and the battery backup required for code compliance.
Tamper switches, door-position monitoring, and request-to-exit sensors generate the audit trail your security team needs. Mechanical contact switches are cheaper; magnetic reed switches resist tampering better. Pair each door with a position switch and a REX sensor at minimum — without door-position monitoring, you can't distinguish 'authorized entry' from 'door held open after authorized entry,' which is a common compliance gap.
Key Specs in This Category
| Spec | Available Options |
|---|---|
| IP Rating | IP66, IP67 |
| Connectivity | Wired |
| Power | AC/DC, PoE |
| Type | Accessory, Controller, Monitor, Lock/Strike, Stainless Steel Endcaps, Intercom, door strike, Maglock Brackets |
| Night Vision | Yes |
Top Brands in This Category
Frequently Asked Questions
Fail-safe or fail-secure for stairwell doors?
Fail-safe is mandatory on most stairwell doors and other code-designated egress paths — the lock must release on fire alarm or power loss to allow evacuation. Fail-secure on those doors is a code violation. Confirm the local fire code and AHJ requirements; commercial buildings in the U.S. follow NFPA 101 and the International Building Code, both of which detail egress lock behavior in detail.
What current draw should I plan for electrified locks?
Typical 12VDC electric strikes draw 200-500 mA continuous, with inrush spikes of 1-2A at engagement. Magnetic locks rated for 1,200 lbs holding force draw around 500 mA continuous at 24VDC. Power supplies need to handle simultaneous lock-down current — emergency lockdown events activate all locks at once. Size the supply with at least 25% headroom and confirm battery backup runtime requirements.
Do I need a request-to-exit (REX) sensor?
Most code-compliant electrified door installations require a REX sensor to shunt the alarm during authorized egress. Without REX, every egress event registers as a forced-door alarm. PIR motion sensors are the common choice and integrate with the door controller's REX input. Mechanical push-bar REX is also acceptable for hardware that includes that switch natively.
Can I use one lock for both card and mechanical key entry?
Yes — most electrified strikes and locks allow mechanical key override on the same door. Maintaining a master key for emergency mechanical access is required by code in many jurisdictions and recommended in all. Document the master key holders carefully; an uncontrolled master key program undermines the electronic audit trail.
What's the lifespan of a magnetic lock?
Quality maglocks (Securitron M62, HES, von Duprin) typically last 15-20 years with no mechanical wear. Failure points are the connector, the armature plate-to-lock alignment, and contamination of the magnetic face. Plan for armature replacement at year 10 as a hedge against alignment drift. Strike-type locks with mechanical parts last 5-10 years before strike-plate wear becomes a reliability issue.
Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.