Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: RP-44MOMENTARY
UPC: 604840298858
Condition: New
Availability: Special Order · Usually Ships in 2-3 Weeks
Write a Review 39% OFF

HES RP-44MOMENTARY Access Control Switch

Momentary push-to-exit switch for card readers and electromagnetic locks

$36.00 $21.99 SAVE $14
Special Order
Usually Ships in 2-3 Weeks

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Experts for pre and post-sales support
Technical and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

Specialized training • U.S - based

Senior Specialist • 877-277-7147

HES RP-44MOMENTARY Access Control Switch

$36.00
$21.99

Overview

SKU: RP-44MOMENTARY
UPC: 604840298858
Condition: New
Availability: Special Order · Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

HES RP-44MOMENTARY Momentary Access Control Switch

The RP-44MOMENTARY combines the proven RP-44 power supply platform with an FA-200 momentary push-to-exit switch, delivering a compact auxiliary control solution for access control installations. This device generates brief contact closure signals to trigger door release mechanisms, reader authentication events, and egress workflows in secured facilities. If you're integrating card readers, keypads, or biometric systems into a multi-door access control architecture, momentary switching is the standard signal type most locking hardware expects — this unit handles that reliably without custom signaling logic.

Key Features

  • Momentary Contact Closure: Delivers a brief electrical pulse when activated, the standard signal type for triggering electromagnetic locks, mag locks, and solenoid-based door release mechanisms. Most access control integrations expect momentary logic — this eliminates the need for custom relay conditioning.
  • 12/24 VDC Auxiliary Switching: Operates across dual voltage rails common in facility power systems, so you can integrate into existing infrastructure without adding separate power conditioning. Flexible voltage support reduces installation complexity across mixed-voltage deployments.
  • Card Reader & Biometric Compatibility: Works with standard access control output protocols — integrates card readers, PIN pads, biometric scanners, and multi-factor authentication workflows without custom interface logic.
  • Standard & Delayed-Egress Support: Handles both immediate push-to-exit scenarios and delayed-egress security applications where compliance or safety codes require a timed release interval.
  • Compact Form Factor: Space-efficient design fits tight electrical closets, equipment racks, and wall-mounted installations where cabinet real estate is limited.
  • RP-44 Platform Reliability: Built on the established RP-44 power supply architecture, a proven design in thousands of access control deployments. Reduces field failure risk and supports long-term parts availability.

Integration & Compatibility

The RP-44MOMENTARY (often searched as RP 44MOMENTARY) integrates into standard access control system architectures that rely on momentary contact closure to drive relay logic and electromechanical actuators. Compatible with card reader systems, proximity keypads, multi-reader authentication controllers, and emergency egress requirements. Designed for indoor installations where access control precision directly impacts facility security and operational continuity — deploy in server rooms, data centers, secured entry points, and commercial buildings. The 12/24 VDC dual-voltage design enables flexible integration into diverse facility power infrastructures without custom conditioning.

When to Choose a Different Model

If your access control system requires a latching (maintained) contact instead of momentary closure — for example, to hold a lock in the open position for extended periods — you'll need an alternative configuration. Consult your access control panel documentation to confirm whether momentary or maintained signaling is required; the two are not interchangeable. Similarly, if you need wireless or networked egress capabilities (WiFi-enabled or IP-based exit triggers), this hardwired momentary switch is not the right fit.

Frequently Asked Questions

Q: What's the difference between momentary and maintained contact closure?

A: Momentary contact closes only while the button is pressed and opens immediately upon release — standard for triggering solenoid locks and electromagnetic strikes. Maintained contact stays closed after activation until manually reset. Most access control systems expect momentary signaling; verify your panel specs before ordering.

Q: Can the RP-44MOMENTARY work with both 12V and 24V systems?

A: Yes. The unit supports 12/24 VDC operation, so it integrates into facilities with mixed voltage infrastructure without requiring separate power supplies for each voltage rail.

Q: Is the RP-44MOMENTARY suitable for delayed-egress door release?

A: Yes. The momentary switch design is compatible with delayed-egress security applications. Verify that your access control panel and door hardware support the timed release interval your security code requires.

Q: What locking hardware does the RP-44MOMENTARY trigger?

A: Momentary contact closure activates electromagnetic locks (mag locks), solenoid-based electric strikes, and push-to-exit mechanisms controlled by your access control panel. Confirm that your specific lock hardware expects momentary signaling, not maintained closure.

Q: Does the RP-44MOMENTARY integrate with biometric or multi-factor authentication readers?

A: Yes. It works with card readers, keypads, biometric scanners, and multi-reader access control architectures. The momentary switch provides the output signal that your authentication system triggers once a credential is verified.

Q: What's the warranty on the RP-44MOMENTARY?

A: Check the product documentation or contact the manufacturer for specific warranty terms. Standard industrial control devices typically carry a 1–2 year manufacturer's warranty; OEM terms vary.

Jerry Tildsen
Jerry Tildsen
Perspective based on aggregated IP Security Depot and affiliated engineering team experience.

The RP-44MOMENTARY is a no-nonsense auxiliary control device built for access control integrations where momentary contact closure is the expected signal type. If your access control panel or door controller is waiting for a brief pulse to trigger lock release, this unit delivers exactly that — nothing more, nothing less. The 12/24 VDC dual-voltage design is a real advantage in facilities with mixed power infrastructure; you don't need separate switches for different voltage zones.

Technical Highlights:

  • Momentary Contact Closure Logic: Outputs a brief electrical pulse on button press, the standard activation signal for solenoid locks, electromagnetic strikes, and relay-based access control workflows. Eliminates the need for custom signal conditioning in most installations.
  • 12/24 VDC Dual Voltage Support: Works across both voltage rails common in facility power systems. Reduces the number of separate power supplies needed and simplifies integration into mixed-voltage deployments.
  • RP-44 Power Supply Platform: Built on a proven architecture deployed in thousands of access control systems. Offers long-term parts availability and reduces the risk of field failures associated with newer, less-tested designs.

Deployment Considerations:

  • Verify your access control panel's output specification before ordering — some systems expect maintained contact instead of momentary closure. The two are not interchangeable, and a mismatch will cause the locking mechanism to fail.
  • Confirm that your door hardware (mag lock, electric strike, or solenoid) is rated for the voltage and contact duration the RP-44MOMENTARY provides. Undersized hardware may chatter or fail prematurely.
  • If you need wireless exit capability, IP-based remote triggering, or networked egress control, this hardwired momentary switch is not the right tool — consider a networked access control receiver instead.

The RP-44MOMENTARY is a solid fit for data centers, server rooms, and multi-door commercial access control systems where reliable, simple momentary switching is non-negotiable. Its dual-voltage design makes it particularly useful in larger facilities with legacy and modern power infrastructure running side-by-side.

Specifications
Form Factor: Momentary Switch
Type: Controller
Weight: 2 lb
Country of Origin: US
Q&A
Reviews
Have Questions? Ask an Expert.

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources