HES
SKU: 1600-104-629
HES 1600-104-629 Bright Stainless Steel Kit
Bright stainless steel kit for HES electric strikes indoors and out
- Corrosion-resistant bright stainless steel for mixed environmental conditions
- Compatible with HES electric strike and access control system platforms
- Professional finish maintains appearance in visible mounting installations
$138.00 $137.99 Save $0.01 -
HES
SKU: 1600-104-630
HES 1600-104-630 Satin Stainless Steel Electric Strike
Satin stainless steel electric strike for standard access control systems
- 24VDC input integrates directly with standard access control panels—no line-voltage wiring.
- Dual fail-safe/fail-secure modes let you configure egress or lockdown behavior per code.
- Satin stainless steel finish resists corrosion in humid environments, reducing replacement cycles.
$59.00 $29.99 Save $29.01 -
HES
SKU: 1600-104-BSP
HES 1600-104-BSP Black Suede Access Control Kit
Black suede access control kit for wall and surface-mounted doors
- Complete hardware components for HES standard door locking systems
- Wall-mounted and surface-mounted installation options for flexible deployment
- 24VDC electric strike rated for commercial and institutional environments
$110.00 $109.99 Save $0.01 -
HES
SKU: 1600-106-613E
HES 1600-106-613E Dark Oxidized Satin Bronze Kit
Dark oxidized satin bronze hardware kit for HES electromagnetic locks
- Complete fastener kit sized for HES electromagnetic locking system installation
- Dark oxidized satin bronze finish resists corrosion indoors and covered outdoor areas
- Satin finish coordinates with institutional and commercial architectural standards
$102.00 $101.99 Save $0.01 -
HES
SKU: 1600-106-629
HES 1600-106-629 Bright Stainless Steel Kit
Bright stainless steel kit for HES 1600-series access control
- Bright stainless steel construction resists corrosion indoors and outdoors
- 24VDC electric strike compatible with HES 1600-series security systems
- Professional-grade finish suitable for visible and exposed installations
$130.00 $129.99 Save $0.01 -
HES
SKU: 1600-106-630
HES 1600-106-630 Satin Stainless Steel Electric Strike
Satin stainless steel electric strike with 12/24 VDC dual-voltage
- Dual-voltage 12/24 VDC input eliminates power conditioning hardware on retrofit and new builds.
- Satin stainless steel resists corrosion and oxidation in high-traffic and healthcare environments.
- Direct ONVIF integration synchronizes unlock signals across Genetec, Milestone, and Axis platforms.
$51.00 $25.99 Save $25.01 -
HES
SKU: 2005M3
HES 2005M3 Electric Strike Power Controller
In-line power controller for HES strikes, 12–32V AC/DC input
- Regulates voltage across wide 12–32V AC/DC range for stable strike operation
- Resettable fuse and MOV surge suppression protect against overcurrent and spikes
- Input Status LED shows real-time power state; compact in-line form for retrofit fit
$138.00 $69.99 Save $68.01 -
HES
SKU: 2006M
HES 2006M Plug-in Buzzer
Plug-in buzzer for HES electric strike systems with 24VDC operation
- Direct integration with HES strike systems for audible access confirmation
- 24VDC powered design works with standard HES electric strike product lines
- Compact form factor supports indoor commercial and institutional deployments
$70.00 $69.99 Save $0.01 -
HES
SKU: 2007M
HES 2007M Plug-in Pigtail Connector 4-Wire
4-wire plug-in pigtail connector for HES electric strike systems
- Plug-in design enables fast field termination and quick-disconnect servicing.
- 4-wire lead configuration supports standard electric strike access control wiring.
- Compatible with HES 9800 and Adams Rite 7800 series electric strike systems.
$27.50 $26.99 Save $0.51 -
HES
SKU: 31-0736-IP
HES 31-0736-IP 24V Coil Solenoid
24V DC coil solenoid for access control and automated gates
- 24V DC coil design works with HES and third-party control systems
- Rated for electronic door locks, gates, and barrier control applications
- Individually packed for secure transport and installation
$330.00 $164.99 Save $165.01 -
HES
SKU: 320S
HES 320S 300 Pound Single Magnetic Lock
300-pound fail-secure magnetic lock for standard access control
- 300 lb holding force secures hollow metal, wood, and aluminum doors
- Dual voltage (12/24 VDC) works with existing access control systems
- Fail-secure design keeps door locked during power loss or interruption
$195.00 $107.99 Save $87.01 -
HES
SKU: 4300-20-101-628
HES 4300-20-101-628 Steel Hawk Electrified Deadlatch
31/32 electrified deadlatch with fail-secure steel construction for access control
- Steel hawk mechanism operates on 12/24 VDC for dual-voltage flexibility
- Integrates with access control systems, electric strikes, and mag locks
- Mounts to hollow metal and wood door frames with fail-secure operation
$584.00 $291.99 Save $292.01 -
HES
SKU: 4300-20-201-313
HES 4300-20-201-313 Aluminum Door Latch
Aluminum latch for HES electrified systems, 31/32 strike, dark bronze
- Dark bronze aluminum construction resists corrosion in commercial buildings
- 31/32 strike configuration fits standard door frame preparations without mods
- Non-monitored assembly integrates with HES electrified locking deployments
$584.00 $291.99 Save $292.01 -
HES
SKU: 4300-20-201-628
HES 4300-20-201-628 Aluminum Latch Door Assembly
Aluminum latch assembly, 31/32 profile, no-monitor for HES systems
- Clear anodized aluminum construction resists corrosion in indoor environments
- 31/32 standard profile fits common door frame installations without modification
- No-monitor configuration eliminates additional wiring and control overhead
$584.00 $291.99 Save $292.01 -
HES
SKU: 4300-3-0-201-313
HES 4300-3-0-201-313 Electrified Deadlatch
Remote-controlled electrified deadlatch for commercial access systems
- 1-1/8 inch backset fits standard commercial door frames without modification
- 24VDC electrified mechanism integrates with institutional access control systems
- Keypad-compatible reader supports real-time remote locking and unlocking
$584.00 $291.99 Save $292.01 -
HES
SKU: 4300-30-101-313
HES 4300-30-101-313 Aluminum Door Latch
Surface-mount aluminum latch, 1-1/8" mechanical, dark bronze anodize
- 1-1/8" mechanical latch operates without electrical monitoring for simple integration
- Dark bronze anodized aluminum resists corrosion in commercial indoor environments
- Surface mount retrofit design works with standard access control wiring schemes
$584.00 $291.99 Save $292.01
Door Relays, Isolators, Locks, & Bolts
Door relays, isolators, electric locks, and bolt hardware connect access control systems to physical door security. Proper selection ensures reliable operation, electrical protection, and compliance with life-safety requirements in commercial deployments.
Plan Your Deployment
- Fail-safe vs fail-secure lock configuration
- Door type and mounting surface compatibility
- Voltage requirements and power supply capacity
- Relay isolation to protect controller boards
- Local fire and building code compliance
Door Relays, Isolators, Locks, & Bolts — Engineering-Grade Door Hardware for Commercial Deployments
This category covers 338 working models of door relays, isolators, locks, & bolts sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.
What to Look For
Fail-safe versus fail-secure determines what happens during power loss. Fail-safe locks unlock on power loss (used on egress doors where life safety dominates); fail-secure locks remain locked (used on storage, server rooms, and exterior doors where security dominates). Code typically mandates fail-safe on stairwell and egress doors. Confirm with the AHJ before specifying — misapplied lock mode is a common code violation.
Strike, mortise, magnetic lock, and electrified panic hardware each have distinct installation, current draw, and code implications. Electric strikes work with most mechanical locksets and are easiest to retrofit. Magnetic locks (maglocks) provide high holding force on glass and wood doors but require dedicated REX and panic-bar interfaces for egress compliance. Verify the door's existing prep before choosing.
Power draw and inrush current dictate power supply sizing. A 5-door system with 1A peak per lock can exceed an undersized 12VDC supply at simultaneous lock-down events. Account for accessories — REX motion sensors, door-position switches, electrified levers — when sizing the supply and the battery backup required for code compliance.
Tamper switches, door-position monitoring, and request-to-exit sensors generate the audit trail your security team needs. Mechanical contact switches are cheaper; magnetic reed switches resist tampering better. Pair each door with a position switch and a REX sensor at minimum — without door-position monitoring, you can't distinguish 'authorized entry' from 'door held open after authorized entry,' which is a common compliance gap.
Key Specs in This Category
| Spec | Available Options |
|---|---|
| IP Rating | IP66, IP67 |
| Connectivity | Wired |
| Power | AC/DC, PoE |
| Type | Accessory, Controller, Monitor, Lock/Strike, Stainless Steel Endcaps, Intercom, door strike, Maglock Brackets |
| Night Vision | Yes |
Top Brands in This Category
Frequently Asked Questions
Fail-safe or fail-secure for stairwell doors?
Fail-safe is mandatory on most stairwell doors and other code-designated egress paths — the lock must release on fire alarm or power loss to allow evacuation. Fail-secure on those doors is a code violation. Confirm the local fire code and AHJ requirements; commercial buildings in the U.S. follow NFPA 101 and the International Building Code, both of which detail egress lock behavior in detail.
What current draw should I plan for electrified locks?
Typical 12VDC electric strikes draw 200-500 mA continuous, with inrush spikes of 1-2A at engagement. Magnetic locks rated for 1,200 lbs holding force draw around 500 mA continuous at 24VDC. Power supplies need to handle simultaneous lock-down current — emergency lockdown events activate all locks at once. Size the supply with at least 25% headroom and confirm battery backup runtime requirements.
Do I need a request-to-exit (REX) sensor?
Most code-compliant electrified door installations require a REX sensor to shunt the alarm during authorized egress. Without REX, every egress event registers as a forced-door alarm. PIR motion sensors are the common choice and integrate with the door controller's REX input. Mechanical push-bar REX is also acceptable for hardware that includes that switch natively.
Can I use one lock for both card and mechanical key entry?
Yes — most electrified strikes and locks allow mechanical key override on the same door. Maintaining a master key for emergency mechanical access is required by code in many jurisdictions and recommended in all. Document the master key holders carefully; an uncontrolled master key program undermines the electronic audit trail.
What's the lifespan of a magnetic lock?
Quality maglocks (Securitron M62, HES, von Duprin) typically last 15-20 years with no mechanical wear. Failure points are the connector, the armature plate-to-lock alignment, and contamination of the magnetic face. Plan for armature replacement at year 10 as a hedge against alignment drift. Strike-type locks with mechanical parts last 5-10 years before strike-plate wear becomes a reliability issue.
Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.