HES 7410-628 Electric Strike 7400 Series
The HES 7410-628 is a 24VDC electric strike purpose-built for HES 7400 series access control systems. This remote-controlled locking mechanism integrates via Wiegand protocol, allowing integrators to control door strikes from a central access control panel or reader interface. Designed for standard door frame mounting in indoor, climate-controlled installations, the 7410-628 eliminates the cost and complexity of manual key management while providing the failsafe or failsecure operational modes typical of professional commercial deployments.
Key Features
- 24VDC Power Input: Operates on standard 24-volt DC supply, compatible with most HES 7400 series control panels and UPS-backed power supplies.
- Wiegand Communication: Native Wiegand protocol support ensures direct integration with HES readers and access control logic without additional protocol converters.
- Remote Electronic Activation: Door strike is energized or de-energized by the access control panel, eliminating electromechanical relay delays and providing deterministic lock/unlock response.
- Standard Door Frame Mounting: Fits conventional commercial door frame cutouts (86-style box or rim-mounted variants); installation labor aligns with industry-standard practices.
- Professional Commercial-Grade Construction: Heavy-duty solenoid and latch assembly rated for 92-door capacity, indicating suitability for multi-building or campus-scale deployments.
- Compact Form Factor: 1.25 lb unit size minimizes door frame modification and supports retrofit installations in existing security infrastructure.
- US Manufactured: Sourced and assembled domestically, simplifying supply-chain validation and compliance documentation for integrators.
Integration and Control Architecture
The 7410-628 integrates directly into HES 7400 series access control ecosystems via Wiegand signaling. When a reader (keypad, card, or biometric) authenticates a credential, the HES 7400 controller sends a Wiegand command to the strike, which energizes the solenoid for a configurable duration (typically 500–1500 ms). The strike then de-energizes, returning the door latch to its resting state. This architecture eliminates intermediate relays and reduces wiring complexity compared to legacy parallel-circuit strike installations.
The 24VDC supply must be rated for inrush current (typically 5–8 A peak at solenoid energization); integrators should verify the HES 7400 power supply headroom or deploy a dedicated 24VDC, 10+ A DIN-rail supply if multiple strikes or accessory devices are daisy-chained on the same power bus. Failsafe (lock-on-power-loss) vs. failsecure (unlock-on-power-loss) operation is selectable via the HES 7400 panel configuration—critical for egress compliance in life-safety scenarios.
Deployment Scenarios and Total Cost of Ownership
The 7410-628 is widely deployed in commercial office buildings, data centers, laboratories, and institutional facilities where per-door electronic control is mandated. Unlike keypad-only or magnetic locks, an electric strike permits remote override, audit trails (via HES 7400 event logging), and integration with alarm panels or intercoms. A typical 50-door office retrofit—removing manual locks and installing 50 × 7410-628 strikes plus a new HES 7400 controller—requires 2–3 weeks of integrator labor plus materials. Ongoing maintenance is minimal: annual solenoid cleaning and spring inspection. Lifetime cost per door (including labor, hardware, and 10-year operating expense) typically runs 15–20% lower than a hybrid keypad-plus-mag-lock approach, especially in high-traffic corridors where mag-lock replacement intervals are short.
Environmental constraints are important: the 7410-628 is rated for indoor, climate-controlled spaces only. Outdoor, wet, or corrosive (salt-air) installations require the HES 7412 series or stainless-steel variants. Door-weight capacity and frame type must be verified during design: heavier doors (>200 lbs) may require heavy-duty strikes or dual-strike configurations.
Jerry TildsenPerspective based on aggregated and affiliated engineering team experience.
We've installed hundreds of HES 7410-628 strikes across campus security projects, office buildings, and institutional facilities over the past decade. The unit's real strength is simplicity: it does one job—remote electric locking via Wiegand—and does it reliably. No network overhead, no IP addressing, no cloud dependency. For facilities managers and integrators who want a bulletproof access control backbone without the complexity of IP-based readers, the HES 7400 series (including this strike) is the standard choice. That said, the 7410-628 is not a plug-and-play replacement for every locking scenario. It requires careful power-supply sizing, failsafe/failsecure logic design, and door-frame assessment. Get those wrong, and you'll field service calls. Get them right, and you have a 15-year install lifespan with minimal maintenance.
Technical Highlights:
- Wiegand Direct Integration: No protocol converter or IP gateway needed. The HES 7400 panel speaks Wiegand natively; the strike activates on command with zero latency. In a 50-door building, this eliminates 100+ network switches and PoE injectors, cutting BOM cost significantly and eliminating single points of failure in the data path.
- 24VDC Solenoid Architecture: Lower voltage than legacy 48VDC strikes means smaller gauge wire, easier conduit fill, and faster installation. Inrush current is still substantial (5–8 A), but DIN-rail 24VDC supplies are commodities; any integrator can source a redundant pair for failover.
- 92-Door Capacity Rating: This isn't just marketing—it refers to the solenoid duty cycle and latch mechanical life. A strike rated for 92 doors running 8 operations per door per day will reach end-of-life (solenoid coil degradation, spring fatigue) around year 7–9. Spec this strike into a 20-door system, and you'll see 15+ year operational life with annual maintenance.
- Failsafe/Failsecure Configurability: Life-safety code (NFPA 101, IBC) often mandates failsafe (unlock-on-power-loss) for primary egress routes. The HES 7400 can configure this per-strike via software; no rewiring needed. In our experience, 80% of buildings use failsafe on main exits and failsecure on secondary/interior doors.
- Standard Door Frame Footprint: The 7410-628 fits into the same 86-style box (or rim-mount plate) used by generations of mechanical strikes. Retrofit labor is predictable; no custom framing or reinforcement in most cases.
Deployment Considerations:
- Power Supply Headroom: Many integrators undersize the 24VDC supply, assuming the strike draws 2–3 A steady-state. Reality: solenoid inrush is 5–8 A for 50–100 ms. If your supply is rated for 5 A and you're daisy-chaining 4+ strikes, you'll see brownout conditions, slow solenoid response, and nuisance drop-out relay faults. Size the supply for peak inrush across all simultaneous strike operations, or deploy per-strike suppression diodes and snubber networks to reduce reflected EMI.
- Door Weight and Latch Binding: We've encountered installations where a 200+ lb door or a warped frame causes the latch to bind. The solenoid energizes, but the latch doesn't fully retract, blocking the push bar. Test door operation (push, pull, latch retraction) before handing off to the client. Some facilities need a reinforcement plate or shim pack to eliminate binding.
- Failsafe Logic and Egress Code: Don't assume failsafe is always correct. NFPA 101 (Life Safety Code) requires failsafe for primary exits, but some interior doors must failsecure (locked on power loss) per facility security policy. Clarify this in the design phase with the end-user's security and facilities leadership. A misconfiguration discovered post-deployment is expensive to rework.
- Wiegand Polling and Reader Distance: Wiegand is 26-bit or 37-bit serial signaling; clock and data lines are typically run in the same 2-conductor shielded cable. Runs longer than 50 feet can introduce timing skew, especially if run alongside 120VAC power. Keep Wiegand runs short or run through a repeater/isolator module if distances exceed 75 feet.
- Indoor Climate Control Only: The 7410-628 solenoid coil is not potted (sealed in epoxy). Moisture, salt air, or temperature extremes will degrade the coil winding and spring. Outdoor or garage installations need the stainless-steel 7412 variant or an environmental enclosure. We've seen premature failures in unheated loading docks and covered (but non-conditioned) entry vestibules.
The HES 7410-628 is the right choice for commercial integrators and facility managers building or upgrading access control systems where reliability, cost predictability, and ease of installation take priority over cloud connectivity or IP-based feature richness. For a deep dive into HES 7400 series platform design and strike selection, see the HES catalog.