Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
No Bots, Just Experts
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
WiremoldT10FC-FW Full Capacity Raceway Entrance End Fitting
The 2410FC-FW is a full-capacity entrance end fitting built for the Wiremold 2400 Series raceway system — the connector piece that lets cable runs transition cleanly from wall or ceiling penetrations into surface raceway without crimping conductor bend radius. It's a small component, but on a structured cabling or security wiring job it's the difference between a code-compliant entrance and a stuffed, kinked mess behind the faceplate. The model number 2410FC-FW identifies the full-capacity variant sized specifically for 2400 Series channel.
Overview
This fitting terminates a 2400 Series raceway run at a wall or ceiling entrance point, giving low-voltage and power conductors a supported transition into the raceway channel. It's rated for indoor use and carries a 600V voltage rating, which covers both electrical wire and copper/fiber data cabling routed through the same cable management system.
Key Features
- 3/4in and 1in concentric trade-size knockouts on each side: gives installers two conduit-entry options per side without ordering a different fitting for each conduit size — cuts SKU count on a multi-run job.
- 600V rating: clears the bar for standard building power circuits as well as low-voltage runs, so the same fitting works whether the raceway is carrying line-voltage or communications cable.
- Compact footprint (2.625in L x 3.0in W x 2.25in H): fits tight entrance points near door frames and corner transitions where a bulkier fitting won't clear.
- 0.43 lb weight: light enough that it doesn't add meaningful load to a raceway run or require extra bracing at the entrance point.
- Full-capacity design: matches the internal channel capacity of 2400 Series raceway rather than a reduced-capacity fitting, so conductor fill calculated for the raceway run carries straight through the entrance without a bottleneck.
Integration & Compatibility
The 2410FC-FW is purpose-built for 2400 Series raceway and is not a universal fitting — confirm your raceway generation before ordering. It pairs naturally with other 2400 Series components when you're planning a full run from entrance to device drop, and it's a common companion part on jobs that also spec racks and cabinets or video surveillance camera drops where power and data need a clean wall entrance. If you're scoping a larger low-voltage pathway, a PoE planning guide is worth a read before finalizing conduit and raceway sizing for the run.
Frequently Asked Questions
Q: What raceway series does the 2410FC-FW fit?
A: The 2410FC-FW is built for 2400 Series raceway specifically — it is a full-capacity entrance end fitting sized to that channel.
Q: What size conduit knockouts does it have?
A: It has 3/4in and 1in concentric trade-size knockouts located on each side of the fitting.
Q: Is the 2410FC-FW rated for indoor or outdoor use?
A: It is rated for indoor use only.
Q: What voltage is the 2410FC-FW rated for?
A: It carries a 600V rating, covering both power and low-voltage data applications.
Q: How much does the 2410FC-FW weigh?
A: It weighs 0.43 lb.

The 2410FC-FW comes up on jobs where a cable run has to punch through a wall and land in 2400 Series raceway without choking down the conductor count. It's a small part, but ordering the wrong entrance fitting means a return trip to the supply house mid-install.
Technical Highlights:
- Dual concentric knockouts (3/4in and 1in): one fitting covers two common conduit sizes per side, so you're not stocking a separate SKU for each conduit diameter feeding the entrance.
- 600V rating: rated high enough to share raceway with building power circuits, not just low-voltage cabling, which matters when a run is mixed-use.
- Full-capacity channel match: the internal capacity matches 2400 Series raceway itself, so you don't lose conductor fill at the entrance point the way you would with a reduced-capacity fitting.
Deployment Considerations:
- Confirm the raceway generation on site before ordering — 2410FC-FW is sized for 2400 Series specifically and won't correctly seat on a different raceway family.
- At 2.625in x 3.0in x 2.25in, it's compact enough for tight entrance points, but that also means fill capacity is finite — plan conductor count before the run, not after.
Specify the 2410FC-FW anywhere a 2400 Series raceway run needs a clean, code-compliant wall or ceiling entrance — typical on commercial retrofit jobs where surface raceway is carrying both power and structured cabling into a single drop point.
Compare with similar
Wiremold Full CAP ENT END Fit-fog - 2410FC-FW
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Wiremold products? Shop the full Wiremold catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology