Smoke Detectors

Selecting a sort option will reload the product list.

Showing Results for Smoke Detectors

  • Save $0.96
    STI STI-9846 Smoke Detector Damage Stopper Controller
    Add to Cart The item has been added

    STI STI-9846

    STI STI-9846 Smoke Detector Damage Stopper Controller

    Damage stopper controller designed to protect smoke detection equipment from intentional or accidental interference in security-critical installations

    • Protects smoke detector integrity against tampering in security-critical installations.
    • Compatible with System Sensor beam units and reflective mirror assemblies.
    • Mounts via four #10 x 1.5" screws; clamp hardware positions on side, top, or bottom.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $72.95 $71.99 Save $0.96
    The item has been added Add to quote
    $72.95 $71.99 Save $0.96
    Save $0.96 Add to cart Add to quote
  • DMP 2W-BLX System Sensor Smoke Detector
    Add to Cart The item has been added

    DMP 2W-BLX

    DMP 2W-BLX System Sensor Smoke Detector

    N addressable single-point sensor module designed for integration with DMP XR Series control panels via the LX-Bus communication backbone

    • Addressable LX-Bus module assigns a unique address per point on XR Series panels.
    • Panel-powered via LX-Bus eliminates dedicated power runs to each sensor location.
    • Single-point zone reporting delivers smoke and fire status directly to the control panel.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $63.99
    The item has been added Add to quote
  • Save $74.01
    DMP 2WT-BLX System Sensor Smoke Detector (view 3)
    Add to Cart The item has been added

    DMP 2WT-BLX

    DMP 2WT-BLX System Sensor Smoke Detector

    Wireless smoke detection for DMP systems without hardwiring

    • Wireless communication eliminates conduit runs for faster deployment in occupied spaces.
    • Integrates with DMP XR Series panels via LX-Bus as an addressable single-point module.
    • Built-in fixed-temperature thermal detector triggers above 135°F for dual-mode detection.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $152.00 $77.99 Save $74.01
    The item has been added Add to quote
    $152.00 $77.99 Save $74.01
    Save $74.01 Add to cart Add to quote
  • Save $153.06
    DSC PG9936 PowerG Wireless Photoelectric Smoke Detector
    Add to Cart The item has been added

    DSC PG9936

    DSC PG9936 PowerG Wireless Photoelectric Smoke Detector

    Wireless photoelectric smoke detector with PowerG encryption and 2 km range

    • PG9936 PowerG photoelectric wireless smoke detector
    • Reduces nuisance alarms vs ionization detectors
    • 85 dB sounder with green/red LED indicators
    Usually Ships in 2-3 Weeks Free shipping over $499
    $283.05 $129.99 Save $153.06
    The item has been added Add to quote
    $283.05 $129.99 Save $153.06
    Save $153.06 Add to cart Add to quote
  • Honeywell PROSIXSMOKEV ProSIX Wireless Smoke/Heat Detector - PROSIXSMOKEV
    Add to Cart The item has been added

    Honeywell PROSIXSMOKEV

    Honeywell ProSIX Wireless Smoke/Heat Detector - PROSIXSMOKEV

    Wireless smoke and heat detector designed for integration with Honeywell's ProSIX wireless security platform

    • Combines optical smoke and heat sensing in one wireless unit, reducing device count.
    • Integrates natively with the ProSIX wireless platform for streamlined panel enrollment.
    • Wireless design eliminates detector wiring runs, cutting installation time and conduit cost.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $65.99
    The item has been added Add to quote
  • Honeywell Wireless Smoke/Heat Detector (view 4)
    Add to Cart The item has been added

    Honeywell 5800SMOKEV

    Honeywell Wireless Smoke/Heat Detector - 5800SMOKEV

    Wireless dual-sensor smoke and heat detector designed to integrate into Honeywell security and fire detection systems

    • Dual photoelectric and thermal sensors cover smoke and heat in one wireless unit.
    • 900 MHz 5800 protocol integrates with VISTA-15P through VISTA-250BPT panels.
    • 2x AA batteries deliver 3–5 years of runtime, reducing maintenance intervals.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $105.99
    The item has been added Add to quote
    $105.99
    Add to cart Add to quote
  • Save $1,329.01
    Potter Butterfly Valve Supervisory Switch (view 3)
    Add to Cart The item has been added

    Potter PIVSU-EX-O

    Potter Butterfly Valve Supervisory Switch

    Butterfly valve supervisory switch for fire sprinkler systems with open/closed status signaling

    • IP66-rated enclosure withstands washdowns and harsh facility environments.
    • NEMA 1/3/4/4X/6/6P/9/13 ratings cover indoor and outdoor installation scenarios.
    • Signals open/closed valve status to fire alarm panels, supporting NFPA 72 compliance.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $2,715.00 $1,385.99 Save $1,329.01
    The item has been added Add to quote
    $2,715.00 $1,385.99 Save $1,329.01
    Save $1,329.01 Add to cart Add to quote
  • Save $53.11
    Potter CO1224T Carbon Monoxide Detector
    Add to Cart The item has been added

    Potter CO1224T

    Potter CO1224T Carbon Monoxide Detector

    Supervised wall-mount CO detector with zone reporting for commercial systems

    • Supervised loop architecture alerts the panel instantly if the detector fails or is removed.
    • Zone-level CO reporting pinpoints the affected location, cutting response time in large facilities.
    • Compact 5.1"×3.3"×1.3" wall/ceiling form factor suits retrofit and new commercial installations.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $149.10 $95.99 Save $53.11
    The item has been added Add to quote
    $149.10 $95.99 Save $53.11
    Save $53.11 Add to cart Add to quote
  • Save $24.71
    Potter CPS-24 Photoelectric Smoke Detector
    Add to Cart The item has been added

    Potter CPS-24

    Potter CPS-24 Photoelectric Smoke Detector

    Photoelectric in-duct smoke detector, 24VDC, low-profile 2" design

    • Photoelectric light-scattering sensor reduces false alarms from duct dust and steam.
    • Runs on 24VDC at 59μA standby, minimizing power-supply load across multi-detector runs.
    • 2" low-profile housing fits tight plenum spaces; 2- or 4-wire base suits legacy or supervised panels.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $72.70 $47.99 Save $24.71
    The item has been added Add to quote
    $72.70 $47.99 Save $24.71
    Save $24.71 Add to cart Add to quote
  • Save $412.01
    Potter MPEX Series Manual Fire Alarm Station (view 2)
    Add to Cart The item has been added

    Potter MPEX

    Potter MPEX Series Manual Fire Alarm Station

    Mechanical pull-lever station for conventional fire alarm panels, no power needed

    • Mechanical pull-lever activation requires no power, network, or software to trigger.
    • Hard-wired conventional circuit integrates directly into monitored alarm zones on standard panels.
    • Compact 6.4" × 3.1" × 4.1" form factor fits standard backboxes in commercial and industrial installs.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $1,258.00 $845.99 Save $412.01
    The item has been added Add to quote
    $1,258.00 $845.99 Save $412.01
    Save $412.01 Add to cart Add to quote
  • Save $1,316.51
    Potter OSYSU-EX-O Outdoor Explosion Proof OS&Y (view 2)
    Add to Cart The item has been added

    Potter OSYSU-EX-O

    Potter OSYSU-EX-O Outdoor Explosion Proof OS&Y

    Explosion-proof OS&Y valve for hazardous outdoor fire suppression

    • Explosion-proof design meets hazardous location codes for Class I and Class II sites.
    • IP66-rated housing resists dust ingress and high-pressure water jets in outdoor installs.
    • OS&Y configuration gives visual stem position confirmation without opening the valve body.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $2,702.50 $1,385.99 Save $1,316.51
    The item has been added Add to quote
    $2,702.50 $1,385.99 Save $1,316.51
    Save $1,316.51 Add to cart Add to quote
  • Save $111.66
    Potter PAD300-DUCT Duct-Mounted Smoke Detector
    Add to Cart The item has been added

    Potter PAD300-DUCT

    Potter PAD300-DUCT Duct-Mounted Smoke Detector

    Photoelectric duct smoke detector for supply/return air plenums

    • Photoelectric sensing catches smoldering fires in duct airstreams before smoke spreads.
    • Integrates with conventional supervised alarm loops for broad panel compatibility.
    • Compact 13.5" x 4.5" x 2.25" form factor fits standard commercial ductwork installations.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $300.65 $188.99 Save $111.66
    The item has been added Add to quote
    $300.65 $188.99 Save $111.66
    Save $111.66 Add to cart Add to quote
  • Save $88.30
    Qolsys QS5110-840 IQ Wireless Smoke Detector 345MHz (view 3)
    Add to Cart The item has been added

    Qolsys QS5110-840

    Qolsys QS5110-840 IQ Wireless Smoke Detector 345MHz

    Wireless 345MHz smoke detector for Qolsys IQ panels, no hardwiring

    • Wireless smoke detector on 345 MHz native to Qolsys IQ sensor net
    • Battery-powered photoelectric smoke sensing - no AC pull needed
    • Operates 40 to 100 degrees F for residential and light-commercial use
    Usually Ships in 2-3 Weeks Free shipping over $499
    $164.29 $75.99 Save $88.30
    The item has been added Add to quote
    $164.29 $75.99 Save $88.30
    Save $88.30 Add to cart Add to quote
  • Save $26.34
    STI 50mm Spacer for Smoke Detector Damage Stopper® - STI-8201-SS
    Add to Cart The item has been added

    STI STI-8201-SS

    STI 50mm Spacer for Smoke Detector Damage Stopper® - STI-8201-SS

    50mm stainless steel spacer engineered to support proper mounting clearance and frame alignment within STI Damage Stopper® protective assemblies for

    • Stainless steel build resists corrosion in moisture and light salt-spray environments.
    • Ensures flush frame seating in Damage Stopper II and Weather Stopper II assemblies.
    • Aligns with standard 7mm masonry drill patterns for straightforward retrofit installs.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $69.33 $42.99 Save $26.34
    The item has been added Add to quote
    $69.33 $42.99 Save $26.34
    Save $26.34 Add to cart Add to quote
  • Save $16.66
    STI STI-8201-W 50mm Spacer for Smoke Detector Damage Stopper® - White Coated S...
    Add to Cart The item has been added

    STI STI-8201-W

    STI 50mm Spacer for Smoke Detector Damage Stopper® - STI-8201-W

    50mm white coated spacer engineered to maintain proper standoff distance between smoke detectors and STI Damage Stopper protective devices during

    • 50mm standoff depth preserves detector optics and prevents sensor interference at mount.
    • White-coated finish resists corrosion and blends with standard commercial interior surfaces.
    • Compatible with Stopper II and Weather Stopper II enclosures for surface or recessed installs.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $44.65 $27.99 Save $16.66
    The item has been added Add to quote
    $44.65 $27.99 Save $16.66
    Save $16.66 Add to cart Add to quote
  • Save $14.31
    STI STI-8100-W Smoke Detector Damage Stopper Flush Mount White
    Add to Cart The item has been added

    STI STI-8100-W

    STI Smoke Detector Damage Stopper® - Flush Mount - STI-8100-W

    Flush-mount polycarbonate protective enclosure designed to shield smoke detectors from accidental or intentional damage in commercial and

    • Flush-mount polycarbonate enclosure protects smoke detectors from physical damage.
    • Slot openings prevent pencil-sized obstructions while preserving airflow and optics.
    • White finish blends with standard ceilings; ships with tamper-resistant fasteners.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $37.30 $22.99 Save $14.31
    The item has been added Add to quote
    $37.30 $22.99 Save $14.31
    Save $14.31 Add to cart Add to quote
  • Save $39.41
    STI STI-8200-SS Smoke Detector Damage Stopper®, Flush Mount - Stainless Steel
    Add to Cart The item has been added

    STI STI-8200-SS

    STI Smoke Detector Damage Stopper® Flush Mount - - STI-8200-SS

    Flush-mount protective cage built from 18-gauge (1.2mm) stainless steel, designed to shield smoke detectors from vandalism and misuse without

    • 18-gauge stainless steel construction resists corrosion in harsh or food-service environments.
    • Perforated cage slots block pencil access, meeting correctional and healthcare tamper standards.
    • 4-point flush mount installs over existing detectors using basic hand tools—no wiring required.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $103.40 $63.99 Save $39.41
    The item has been added Add to quote
    $103.40 $63.99 Save $39.41
    Save $39.41 Add to cart Add to quote
  • Save $27.51
    STI STI-8200-W Smoke Detector Damage Stopper®, Flush Mount - White Coated Steel
    Add to Cart The item has been added

    STI STI-8200-W

    STI Smoke Detector Damage Stopper® Flush Mount - - STI-8200-W

    Flush-mount protective cage constructed from 16-gauge white coated cold-rolled steel designed to shield smoke detectors from physical damage and

    • 16-gauge cold-rolled steel cage resists physical damage and tampering in high-vandalism sites.
    • Perforated matrix blocks pencil-sized intrusions while allowing full smoke reach to detector.
    • Tool-free flush or surface mount over existing detectors; four-point fastening for quick access.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $70.50 $42.99 Save $27.51
    The item has been added Add to quote
    $70.50 $42.99 Save $27.51
    Save $27.51 Add to cart Add to quote
  • Save $0.08
    STI Smoke Detector Damage Stopper® with Conduit - STI-8130
    Add to Cart The item has been added

    STI STI-8130

    STI Smoke Detector Damage Stopper® with Conduit - STI-8130

    Polycarbonate protective stopper designed to shield smoke detectors from physical impact during door frame assembly, lock, and strike installation

    • Polycarbonate shell blocks impact from tools and hardware during frame installation.
    • Clear construction allows detector status verification without removing the stopper.
    • No detector or frame modification required; mounts as a protective overlay with tamper-resistant fasteners.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $44.07 $43.99 Save $0.08
    The item has been added Add to quote
    $44.07 $43.99 Save $0.08
    Save $0.08 Add to cart Add to quote
  • Save $0.59
    STI Smoke Detector Damage Stopper® with Conduit Spacer - White Coat... (view 3)
    Add to Cart The item has been added

    STI STI-8230-W

    STI Smoke Detector Damage Stopper® with Conduit Spacer - White Coat...

    Protective housing for smoke detectors in high-traffic areas with integral conduit spacer

    • 16-gauge cold-rolled steel cage with white polyester coat resists corrosion in wet areas.
    • Perforated matrix maintains smoke detection sensitivity while blocking physical tampering.
    • Four-point retrofit mount fits existing detectors with conduit spacer—no rewiring required.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $104.58 $103.99 Save $0.59
    The item has been added Add to quote
    $104.58 $103.99 Save $0.59
    Save $0.59 Add to cart Add to quote
  • Save $13.36
    STI STI-8100 Smoke Detector Damage Stopper Flush Mount Strike
    Add to Cart The item has been added

    STI STI-8100

    STI STI-8100 Smoke Detector Damage Stopper Flush Mount Strike

    Flush mount strike protects door hardware in access control systems

    • Flush mount design integrates seamlessly into standard door frames
    • Clear protective housing maintains visibility of strike mechanism
    • Tamper-resistant fasteners included for secure installation
    Usually Ships in 2-3 Weeks Free shipping over $499
    $35.35 $21.99 Save $13.36
    The item has been added Add to quote
    $35.35 $21.99 Save $13.36
    Save $13.36 Add to cart Add to quote
  • Save $14.31
    STI STI-8100-BK Smoke Detector Damage Stopper Flush Mount
    Add to Cart The item has been added

    STI STI-8100-BK

    STI STI-8100-BK Smoke Detector Damage Stopper Flush Mount

    Flush-mount smoke detector enclosure with TCP/IP monitoring for secure access environments

    • TCP/IP-enabled remote monitoring integrates with building management and security systems
    • Flush mount design fits standard smoke detector installations without surface protrusion
    • Tamper-resistant fasteners included; simple installation and removal for maintenance access
    Usually Ships in 2-3 Weeks Free shipping over $499
    $37.30 $22.99 Save $14.31
    The item has been added Add to quote
    $37.30 $22.99 Save $14.31
    Save $14.31 Add to cart Add to quote
  • Save $0.51
    STI STI-8230-SS Smoke Detector Damage Stopper with Conduit Spacer (view 2)
    Add to Cart The item has been added

    STI STI-8230-SS

    STI STI-8230-SS Smoke Detector Damage Stopper with Conduit Spacer

    Stainless steel smoke detector guard with integrated conduit spacer

    • Stainless steel housing resists corrosion in kitchens, laundries, and humid spaces.
    • Integrated conduit spacer eliminates separate hardware and reduces ceiling installation labor.
    • Open guard geometry preserves detector airflow and optical path for reliable smoke response.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $164.50 $163.99 Save $0.51
    The item has been added Add to quote
    $164.50 $163.99 Save $0.51
    Save $0.51 Add to cart Add to quote
  • Save $0.62
    STI STI-9712 Steel Web Stopper for Photoelectric Smoke Detector (view 3)
    Add to Cart The item has been added

    STI STI-9712

    STI STI-9712 Steel Web Stopper for Photoelectric Smoke Detector

    Patented steel web stopper shields photoelectric smoke detectors from tampering

    • Patented steel web lock physically blocks detector removal and lens obstruction.
    • Smoke entry and airflow remain unobstructed, preserving full detection sensitivity.
    • Mounts to wall or ceiling at 4.62"×5.37"×3" with standard fasteners included.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $55.61 $54.99 Save $0.62
    The item has been added Add to quote
    $55.61 $54.99 Save $0.62
    Save $0.62 Add to cart Add to quote
  • Save $0.63
    STI STI-9713 Steel Web Stopper for Photoelectric Smoke Detector
    Add to Cart The item has been added

    STI STI-9713

    STI STI-9713 Steel Web Stopper for Photoelectric Smoke Detector

    Steel web protector for photoelectric smoke detectors in high-abuse areas

    • 9-gauge steel web construction resists intentional damage in high-abuse environments.
    • Rated -40° to 212°F with LLDPE coating; 304 SS variant supports washdown areas.
    • Tool-free removal preserves routine detector maintenance without special procedures.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $47.62 $46.99 Save $0.63
    The item has been added Add to quote
    $47.62 $46.99 Save $0.63
    Save $0.63 Add to cart Add to quote
  • Save $0.88
    STI STI-9845 Smoke Detector Damage Stopper Controller
    Add to Cart The item has been added

    STI STI-9845

    STI STI-9845 Smoke Detector Damage Stopper Controller

    Smoke detector damage stopper controller that integrates protective functionality into access control and facility monitoring deployments

    • Prevents tampering with smoke detectors in retail floors and access-controlled corridors.
    • Compatible with System Sensor beam and detector units for integrated facility protection.
    • Supports standard conduit routing and mechanical mounting for straightforward installation.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $40.87 $39.99 Save $0.88
    The item has been added Add to quote
    $40.87 $39.99 Save $0.88
    Save $0.88 Add to cart Add to quote
  • Save $0.06
    System Sensor 2151 Photoelectric Low-Profile Plug-In Smoke Detector
    Add to Cart The item has been added

    System Sensor 2151

    System Sensor 2151 Photoelectric Low-Profile Plug-In Smoke Detector

    Photoelectric smoke detector, 120VAC plug-in, low-profile ceiling mount

    • Photoelectric sensing detects smoldering fires and visible smoke particles at 120VAC.
    • Plug-in form factor mounts to standard 120VAC outlets, eliminating new hardwire runs.
    • Low-profile 7.0 x 7.0 x 1.0 in. body fits tight retrofit spaces where hardwired units won't.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $106.05 $105.99 Save $0.06
    The item has been added Add to quote
    $106.05 $105.99 Save $0.06
    Save $0.06 Add to cart Add to quote
  • Save $30.64
    System Sensor 2W-B Photoelectric Smoke Detector 24VDC (view 2)
    Add to Cart The item has been added

    System Sensor 2W-B

    System Sensor 2W-B Photoelectric Smoke Detector 24VDC

    24VDC photoelectric smoke detector with 2-wire supervised circuit

    • 2-wire supervised circuit cuts cable runs and conduit costs on large floor plates.
    • 24 VDC operation integrates directly into standard building fire alarm power buses.
    • Photoelectric sensing targets smoldering fires, reducing false alarms in kitchens and mechanical rooms.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $86.63 $55.99 Save $30.64
    The item has been added Add to quote
    $86.63 $55.99 Save $30.64
    Save $30.64 Add to cart Add to quote
  • Save $32.04
    System Sensor 2WT-B i3 Series Photoelectric Smoke Detector with The...
    Add to Cart The item has been added

    System Sensor 2WT-B

    System Sensor 2WT-B i3 Series Photoelectric Smoke Detector with The...

    Networked photoelectric smoke detector with TCP/IP and NFC credentials

    • Stop-Drop 'N Lock head separates rough-in from trim-out, reducing install labor.
    • Built-in drift compensation and smoothing algorithms cut nuisance alarms in dusty spaces.
    • Mounts to 3½-inch octagonal, single-gang boxes, or drywall anchors on 35VDC systems.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $95.03 $62.99 Save $32.04
    The item has been added Add to quote
    $95.03 $62.99 Save $32.04
    Save $32.04 Add to cart Add to quote
  • Save $35.31
    System Sensor 2WTA-B i3 Series Photoelectric Smoke Detector with Th...
    Add to Cart The item has been added

    System Sensor 2WTA-B

    System Sensor 2WTA-B i3 Series Photoelectric Smoke Detector with Th...

    Dual smoke and heat detection on two-wire 35VDC loop

    • Photoelectric and thermal sensing on a single 35VDC two-wire loop simplifies wiring.
    • i3 drift compensation reduces false alarms in warehouses, offices, and mechanical rooms.
    • Stop-Drop 'N Lock plug-in base enables fast field swap-outs without rewiring terminals.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $111.30 $75.99 Save $35.31
    The item has been added Add to quote
    $111.30 $75.99 Save $35.31
    Save $35.31 Add to cart Add to quote
  • Save $41.91
    System Sensor 2WTR-B i3 Series Photoelectric Smoke Detector (view 3)
    Add to Cart The item has been added

    System Sensor 2WTR-B

    System Sensor 2WTR-B i3 Series Photoelectric Smoke Detector

    Photoelectric smoke detector with TCP/IP networking and 35VDC operation

    • Photoelectric sensing reduces nuisance alarms from dust and cooking smoke.
    • TCP/IP communication integrates directly into existing Ethernet infrastructure.
    • 35VDC operation simplifies retrofits; mounts to standard 3½-inch octagonal back box.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $123.90 $81.99 Save $41.91
    The item has been added Add to quote
    $123.90 $81.99 Save $41.91
    Save $41.91 Add to cart Add to quote
  • Save $32.61
    System Sensor 4W-B Photoelectric Smoke Detector (view 3)
    Add to Cart The item has been added

    System Sensor 4W-B

    System Sensor 4W-B Photoelectric Smoke Detector

    4-wire photoelectric smoke detector for hardwired fire alarm systems

    • 4-wire circuit separates power and signal, reducing false alarms in electrically noisy spaces.
    • 35VDC operation matches standard FACP output—no external power conversion or added components.
    • Mounts to a 3½-inch octagonal back box; fits wall or ceiling in 0°C–49°C environments.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $96.60 $63.99 Save $32.61
    The item has been added Add to quote
    $96.60 $63.99 Save $32.61
    Save $32.61 Add to cart Add to quote
  • Save $35.96
    System Sensor 4WT-B 4-Wire Addressable Photoelectric Smoke Detector
    Add to Cart The item has been added

    System Sensor 4WT-B

    System Sensor 4WT-B 4-Wire Addressable Photoelectric Smoke Detector

    4-wire addressable photoelectric smoke detector with NFC programming

    • Addressable 4-wire architecture lets each detector carry a unique address, cutting zone wiring runs.
    • 35VDC operation aligns with standard fire control panels, simplifying power distribution planning.
    • Photoelectric sensing reduces false alarms in kitchens and parking structures vs. ionization types.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $103.95 $67.99 Save $35.96
    The item has been added Add to quote
    $103.95 $67.99 Save $35.96
    Save $35.96 Add to cart Add to quote
  • Save $39.86
    System Sensor 4WTA-B 4-Wire Photoelectric Smoke Detector (view 3)
    Add to Cart The item has been added

    System Sensor 4WTA-B

    System Sensor 4WTA-B 4-Wire Photoelectric Smoke Detector

    4-wire hardwired photoelectric smoke detector for 24 VDC fire systems

    • Runs on 24 VDC panel supply — no added converters or external power sources required.
    • NFC 13.56 MHz enables secure on-device commissioning without network or cloud access.
    • Mounts to a 3½-inch octagonal back box on wall or ceiling; 5.3 in. diameter footprint.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $122.85 $82.99 Save $39.86
    The item has been added Add to quote
    $122.85 $82.99 Save $39.86
    Save $39.86 Add to cart Add to quote
  • Save $52.86
    System Sensor 4WTAR-B i3 Series 4-Wire Photoelectric Smoke Detector...
    Add to Cart The item has been added

    System Sensor 4WTAR-B

    System Sensor 4WTAR-B i3 Series 4-Wire Photoelectric Smoke Detector...

    4-wire addressable photoelectric smoke detector for monitored fire systems

    • 4-wire addressable protocol enables point ID and real-time status on compatible panels.
    • Photoelectric detection reliably identifies smoldering fires and obscuration-based smoke.
    • NFC 13.56 MHz credential support allows field configuration and testing without tools.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $143.85 $90.99 Save $52.86
    The item has been added Add to quote
    $143.85 $90.99 Save $52.86
    Save $52.86 Add to cart Add to quote
  • Save $42.21
    System Sensor 4WTR-B i3 Series 4-Wire Photoelectric Smoke Detector ...
    Add to Cart The item has been added

    System Sensor 4WTR-B

    System Sensor 4WTR-B 4-Wire Addressable Photoelectric Smoke Detector

    4-wire addressable photoelectric smoke detector for networked fire systems

    • Addressable 4-wire loop gives the control panel exact detector-level alarm location.
    • Photoelectric light-scattering detects smoldering smoke early on 24VDC loop power.
    • NFC 13.56 MHz enables credential-based configuration without removing the detector.
    Usually Ships in 2-3 Weeks Free shipping over $499
    $130.20 $87.99 Save $42.21
    The item has been added Add to quote
    $130.20 $87.99 Save $42.21
    Save $42.21 Add to cart Add to quote

Smoke Detectors

Commercial smoke detectors for addressable and conventional fire alarm systems. Photoelectric, ionization, and multi-criteria sensors provide early smoke detection with drift compensation and environmental adaptation for reliable performance in commercial spaces.

Plan Your Deployment

  • Select detection technology: photoelectric for smoldering fires, ionization for fast-flaming, or multi-criteria
  • Confirm detector base compatibility with installed SLC loop or zone wiring
  • Evaluate sensitivity settings and drift compensation for the environment type
  • Specify spacing per NFPA 72 for ceiling height and air-handling conditions
  • Plan detector placement avoiding HVAC supply registers and dead air spaces
Design Fire Detection Layout Browse Access Control

Smoke Detectors — Engineering-Grade Fire Detection for Commercial Deployments

This category covers 5 working models of smoke detectors sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.

What to Look For

Addressable versus conventional architecture is the first decision. Conventional systems group detectors into zones; addressable systems identify the exact device that triggered. For buildings above 10,000 sq ft or with more than 20 detectors, addressable saves substantial diagnostic time and meets most modern code requirements. Conventional panels remain economical for small commercial buildings and retrofits where new wiring isn't feasible.

UL 864 listing is non-negotiable for the panel; UL 268 for smoke detectors, UL 521 for heat detectors. The AHJ will reject anything else. Beyond UL, look for FM Approval and CSFM (California) listings — many jurisdictions accept only those. Confirm panel-to-detector compatibility within the manufacturer's listed combinations; mixing brands across UL listings voids the panel's certification.

Notification appliance circuit (NAC) capacity, voltage drop, and battery backup sizing drive panel sizing more than detector count does. ADA-compliant strobes draw 75-175 mA each — a 50-strobe building exceeds many small NAC ratings. Calculate total NAC load with voltage-drop budget for the longest run, and size standby battery for 24 hours plus 5 minutes alarm per NFPA 72.

Central station communication, networked panel federation, and graphical workstations matter most in multi-building campuses. Single-building panels typically dial a central station via cellular and IP; multi-building campuses run proprietary peer-to-peer networks (Notifier NFN, Siemens FN-2127, Edwards SIGA) with master annunciation. Plan the integration topology before ordering panels — head-end choice affects which compatible peripherals you can deploy.

Key Specs in This Category

SpecAvailable Options
TypeCarbon Monoxide Detector, Detector, Manual Fire Alarm Station, Explosion Proof, Switch

Top Brands in This Category

Frequently Asked Questions

Do I need an addressable or conventional fire alarm panel?

Addressable panels identify the specific detector in alarm; conventional panels identify only the zone. NFPA 72 and most local codes require addressable for buildings above certain occupancy or square-footage thresholds, but the practical break-even is around 20-30 detectors. Above that count, addressable saves diagnostic and maintenance time. Below it, conventional is often the budget-friendly choice.

What's the difference between photoelectric and ionization smoke detectors?

Photoelectric detectors respond fastest to smoldering fires (cigarettes, electrical wiring); ionization detectors respond fastest to flaming fires (paper, kitchen). Modern dual-sensor detectors include both technologies and meet UL 268 7th edition requirements. Most jurisdictions now require dual-sensor or photoelectric for new commercial installations. Ionization-only is being phased out due to nuisance-alarm performance in cooking and shower-steam scenarios.

How often must fire alarm systems be inspected?

NFPA 72 requires annual inspection and testing of the entire system, semiannual battery testing, and monthly visual inspection of the panel. Local AHJ requirements often mandate documentation and a service contract with a licensed contractor. The owner-of-record bears legal responsibility for inspections — missing an annual inspection exposes the owner to fines and insurance claim denial.

Do I need a duct smoke detector?

Yes if the HVAC system exceeds 2,000 CFM (commercial threshold) — code requires duct smoke detectors that shut down the HVAC to prevent smoke distribution during a fire. Confirm CFM rating against local code thresholds; many jurisdictions require duct detection on smaller systems serving multiple-occupancy buildings. Duct detectors must report to the building's fire alarm panel.

What battery backup is required for fire panels?

NFPA 72 requires 24 hours of standby operation plus 5 minutes in full alarm. Calculate panel current draw under both conditions, then specify a battery with adequate Ah capacity. Lead-acid batteries lose capacity in cold environments — derate by 20% for unconditioned spaces. Replace batteries every 4-5 years even if they test good; failure rates climb steeply after year 5.

Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.