Door Relays, Isolators, Locks, & Bolts
Showing Results for Door Relays, Isolators, Locks, & Bolts
-
Camden
SKU: CM-PT375SS-7
Camden Stainless steel endcaps, 7\" length (Formerly CM-PTSS38-7)
7" stainless steel endcaps for corrosion-resistant Camden access control
- Corrosion-resistant stainless steel construction rated for outdoor environments
- 7-inch length compatible with Camden access control door systems
- TCP/IP and RS-232 communication support for integrated security deployments
$18.00 $11.99 Save $6.01 -
Camden
SKU: CM-PT250-12
Camden Zamac endcaps, 12” length (Formerly CM-PTS14)
12" zamac endcaps for access control door hardware installations
- Zamac construction resists corrosion in standard indoor environments
- 12-inch length fits standard door opening frame assemblies
- Includes mounting screws, anchor plugs, and cable connectors
$18.00 $11.99 Save $6.01 -
HES
SKU: 1000-110
HES 1000-110 Replacement Strike Plate
Genuine HES replacement strike plate for 24VDC electric strike systems
- Steel construction compatible with HES electric strike product lines
- Fits standard commercial door frame configurations for access control
- Replacement component for wear, damage, or system reconfiguration needs
$139.50 $138.99 Save $0.51 -
HES
SKU: 10305LA
HES 10305LA 2-Pin Transfer Part
2-pin transfer part for HES electric strike systems and retrofits
- 2-pin configuration integrates with HES electric strike platforms
- Operates at 6VDC for access control system installations
- Professional-grade construction for new builds, maintenance, and retrofits
$310.00 $170.99 Save $139.01 -
HES
SKU: 10306LA
HES 10306LA Current Transmitter Two-Leaf Door/Window
Current transmitter for dual-leaf doors/windows in HES systems
- Monitor two paired entry points simultaneously with real-time status
- Integrates directly into HES access control infrastructure
- Built for institutional, commercial, and industrial security facilities
$207.00 $114.99 Save $92.01 -
HES
SKU: 1200L
HES 1200L Electromagnetic Lock
Fail-safe electromagnetic lock for single and double doors, stays locked during power loss
- Relay-activated operation integrates with standard access control systems without custom wiring
- Remains locked during power interruptions, protecting secured areas when grid or system fails
- Minimal maintenance design reduces long-term upkeep costs across multi-door commercial deployments
$357.00 $196.99 Save $160.01 -
HES
SKU: 1200LB
HES 1200LB Single Magnetic Lock – 1200 lb Holding Force
1200 lb magnetic lock with dual voltage and built-in sensors
- 1200 lb holding force for standard single-leaf institutional doors
- Jumper-selectable 12 or 24 VDC operation—no power conversion needed
- Integrated bond and door status sensors with LED indicator feedback
$470.00 $259.99 Save $210.01 -
HES
SKU: 1200LBPCB
HES 1200LBPCB PC Board for 1200LB Strike Lock
Replacement PC board for HES 1200LB electric strike locks
- PC board for the HES 1200LB magnetic lock strike
- Converts access control inputs to precise activation pulses
- 24VDC drop-in board for fault-clearing lock systems
$35.00 $19.99 Save $15.01 -
HES
SKU: 1200LDURO
HES 1200LDURO 1200 Pound Electric Lock with LED
1200-pound electric strike with LED status for 12V DC access control
- 1200-pound holding force for commercial door strike applications
- LED indicator shows real-time lock engagement without extra diagnostics
- Duro corrosion-resistant finish rated for high-traffic indoor environments
$409.00 $225.99 Save $183.01 -
HES
SKU: 1200PCB
HES 1200PCB PC Board Control Module
Control module for HES 1200 Series electronic strikes, 12VDC operation
- Operates at 24VDC, compatible with standard access control power supplies.
- Rack-mountable PC board fits 19-inch relay racks and standard electrical enclosures.
- Direct drop-in for HES 1200 Series strikes; no adapter boards or interface modules required.
$30.00 $16.99 Save $13.01 -
HES
SKU: 1200S
HES 1200S Fail-Safe Electromagnetic Lock
Fail-safe electromagnetic lock for standard door frames, 12/24VDC
- Defaults to locked during power loss or system failure for perimeter security
- Compact design fits standard commercial door frames without modifications
- Integrates with common access control systems and badge readers
$293.00 $161.99 Save $131.01 -
HES
SKU: 1200SDURO
HES 1200SDURO Heavy-Duty Electromagnetic Lock
24/7 electromagnetic lock for institutional access control
- Continuous duty operation maintains holding force round-the-clock
- 24VDC standard integration with ANSI/BHMA access control systems
- Fail-safe compatible design for institutional and industrial facilities
$369.00 $203.99 Save $165.01 -
HES
SKU: 1200WP
HES 1200WP Electromagnetic Lock Weatherproof
Fail-secure electromagnetic lock rated for outdoor rain, salt spray, and freeze-thaw cycles
- Sealed IP-rated housing withstands rain, salt spray, dust on exterior doors and loading docks
- Fail-secure solenoid keeps door locked during power loss or access control system outage
- Fits single and double glass doors; operates -40°C to 60°C on 12VDC or 24VDC
$449.00 $247.99 Save $201.01 -
HES
SKU: 15.23--08940R11
HES 15.23--08940R11 Electric Strike
24VDC electric strike for access control integration on standard doors
- Compatible with access control systems for electronically triggered door release
- Indoor-rated strike designed for standard door frame mounting
- Operates on 24VDC input for integration into facility security infrastructure
$135.00 $74.99 Save $60.01 -
HES
SKU: 15.23--08990R11
HES 15.23--08990R11 Electric Strike
12V DC electric strike with fail-secure/fail-safe modes for access control
- Configurable fail-secure or fail-safe operation for flexible security requirements
- 12V DC powered, compatible with standard access control panels and systems
- Mounts directly into standard door frames without structural modifications
$229.00 $126.99 Save $102.01 -
HES
SKU: 1600-104-613E
HES 1600-104-613E Dark Oxidized Satin Bronze Hardware Kit
Dark oxidized satin bronze hardware kit for HES electromechanical locks
- Finish-matched components coordinate across multiple HES locking devices
- Ready for indoor and standard indoor/outdoor access control installations
- Complete assembly eliminates hardware finish inconsistencies on multi-door projects
$110.00 $109.99 Save $0.01
Door Relays, Isolators, Locks, & Bolts
Door relays, isolators, electric locks, and bolt hardware connect access control systems to physical door security. Proper selection ensures reliable operation, electrical protection, and compliance with life-safety requirements in commercial deployments.
Plan Your Deployment
- Fail-safe vs fail-secure lock configuration
- Door type and mounting surface compatibility
- Voltage requirements and power supply capacity
- Relay isolation to protect controller boards
- Local fire and building code compliance
Door Relays, Isolators, Locks, & Bolts — Engineering-Grade Door Hardware for Commercial Deployments
This category covers 338 working models of door relays, isolators, locks, & bolts sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.
What to Look For
Fail-safe versus fail-secure determines what happens during power loss. Fail-safe locks unlock on power loss (used on egress doors where life safety dominates); fail-secure locks remain locked (used on storage, server rooms, and exterior doors where security dominates). Code typically mandates fail-safe on stairwell and egress doors. Confirm with the AHJ before specifying — misapplied lock mode is a common code violation.
Strike, mortise, magnetic lock, and electrified panic hardware each have distinct installation, current draw, and code implications. Electric strikes work with most mechanical locksets and are easiest to retrofit. Magnetic locks (maglocks) provide high holding force on glass and wood doors but require dedicated REX and panic-bar interfaces for egress compliance. Verify the door's existing prep before choosing.
Power draw and inrush current dictate power supply sizing. A 5-door system with 1A peak per lock can exceed an undersized 12VDC supply at simultaneous lock-down events. Account for accessories — REX motion sensors, door-position switches, electrified levers — when sizing the supply and the battery backup required for code compliance.
Tamper switches, door-position monitoring, and request-to-exit sensors generate the audit trail your security team needs. Mechanical contact switches are cheaper; magnetic reed switches resist tampering better. Pair each door with a position switch and a REX sensor at minimum — without door-position monitoring, you can't distinguish 'authorized entry' from 'door held open after authorized entry,' which is a common compliance gap.
Key Specs in This Category
| Spec | Available Options |
|---|---|
| IP Rating | IP66, IP67 |
| Connectivity | Wired |
| Power | AC/DC, PoE |
| Type | Accessory, Controller, Monitor, Lock/Strike, Stainless Steel Endcaps, Intercom, door strike, Maglock Brackets |
| Night Vision | Yes |
Top Brands in This Category
Frequently Asked Questions
Fail-safe or fail-secure for stairwell doors?
Fail-safe is mandatory on most stairwell doors and other code-designated egress paths — the lock must release on fire alarm or power loss to allow evacuation. Fail-secure on those doors is a code violation. Confirm the local fire code and AHJ requirements; commercial buildings in the U.S. follow NFPA 101 and the International Building Code, both of which detail egress lock behavior in detail.
What current draw should I plan for electrified locks?
Typical 12VDC electric strikes draw 200-500 mA continuous, with inrush spikes of 1-2A at engagement. Magnetic locks rated for 1,200 lbs holding force draw around 500 mA continuous at 24VDC. Power supplies need to handle simultaneous lock-down current — emergency lockdown events activate all locks at once. Size the supply with at least 25% headroom and confirm battery backup runtime requirements.
Do I need a request-to-exit (REX) sensor?
Most code-compliant electrified door installations require a REX sensor to shunt the alarm during authorized egress. Without REX, every egress event registers as a forced-door alarm. PIR motion sensors are the common choice and integrate with the door controller's REX input. Mechanical push-bar REX is also acceptable for hardware that includes that switch natively.
Can I use one lock for both card and mechanical key entry?
Yes — most electrified strikes and locks allow mechanical key override on the same door. Maintaining a master key for emergency mechanical access is required by code in many jurisdictions and recommended in all. Document the master key holders carefully; an uncontrolled master key program undermines the electronic audit trail.
What's the lifespan of a magnetic lock?
Quality maglocks (Securitron M62, HES, von Duprin) typically last 15-20 years with no mechanical wear. Failure points are the connector, the armature plate-to-lock alignment, and contamination of the magnetic face. Plan for armature replacement at year 10 as a hedge against alignment drift. Strike-type locks with mechanical parts last 5-10 years before strike-plate wear becomes a reliability issue.
Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.