Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: 600WP
UPC: 604840848763
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 45% OFF

HES 600WP Electromagnetic Lock 600lb Holding Force

600lb weatherproof electromagnetic lock for outdoor access control

$325.00 $179.99 SAVE $145

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

HES 600WP Electromagnetic Lock 600lb Holding Force

$325.00
$179.99

Overview

SKU: 600WP
UPC: 604840848763
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

HES 600WP Electromagnetic Lock

The HES 600WP is an electromagnetic lock engineered for access control applications where weather exposure and security demands intersect. Rated at 600 pounds of holding force, this weatherproof-rated unit provides reliable locking across loading docks, outdoor gates, covered entryways, and industrial facility perimeters. Unlike mechanical locks, the 600WP integrates directly with your access control system—readers, panels, and badge credentials control locking and unlocking remotely, eliminating key management overhead and creating an auditable access log.

Key Features

  • 600-pound holding force: Sufficient for standard single-leaf doors and lightweight double doors in high-traffic environments. If you're securing heavy, reinforced, or bi-parting doors, validate force requirements with your door frame and closer specifications first.
  • Weatherproof (WP) construction: Rated for outdoor installations, rain exposure, temperature swings, and moisture—typical for loading dock areas, covered canopies, and perimeter access points. This is not submersible; skip this model if you need full underwater or high-pressure washdown tolerance.
  • Electromagnetic fail-safe operation: During power loss, the lock defaults to secure (locked). This design prioritizes security over convenience—no emergency battery or manual override enables access during an outage unless your code of jurisdiction mandates fail-secure behavior. Confirm local fire and life-safety codes before deployment.
  • Remote locking and unlocking: Pairs with standard access control panels, badge readers, and integrated system controllers. No special protocol required; the 600WP works with mainstream platforms like Honeywell, Lenel, Genetec, and Milestone if your reader output supports standard lock relay wiring.
  • Low power consumption: Reduces demand on your power supply and access control panel. Typical electromagnetic locks draw 1–2 amps at 12VDC during engagement; lower power means smaller UPS capacity and fewer power budget conflicts on shared electrical runs to card readers or other devices.
  • Durable construction for commercial and industrial environments: Aluminum and stainless-steel components withstand corrosion and mechanical stress. Suitable for manufacturing floors, warehouses, and outdoor security checkpoints where plastic or light-duty locks fail quickly.

Integration & Compatibility

The 600WP connects to access control systems via standard 12VDC or 24VDC relay outputs. Your system controller energizes the lock coil when an authorized badge is presented; de-energizing the relay releases the lock. This is true of all mainstream access control platforms—Honeywell ProWatch, Lenel OnGuard, Genetec Security Center, Salto, and others. Ensure your panel has a spare relay circuit and sufficient amperage capacity for the lock's coil draw (typically 1–2A peak during engagement). If your facility is moving from mechanical key locks to electronic access, the 600WP requires minimal wiring changes and integrates into existing door frames without structural modifications in most cases.

Typical Deployment Scenarios

The HES 600WP fits warehouse and industrial settings where controlled access to restricted zones is non-negotiable. Loading dock doors, inventory rooms, production areas, and outdoor perimeter gates all benefit from centralized, auditable access logging. Outdoor gate installations see the most value from the weatherproof rating—gate frames exposed to rain and sun experience faster mechanical lock corrosion and jamming, whereas the sealed electromagnetic design shrugs off moisture.

When to Choose a Different Model

If your facility requires fail-safe (unlock on power loss) behavior for emergency egress, specify a fail-safe variant instead—the standard 600WP is fail-secure only. If you need higher holding force—say, for heavy fire-rated doors or double-leaf gates—explore higher-amperage or larger-format electromagnetic locks in the HES portfolio. For indoor-only, climate-controlled environments, a non-weatherproof electromagnetic lock may offer cost savings, though the weatherproof premium is modest and future-proofs against moisture intrusion.

Frequently Asked Questions

Q: Is the HES 600WP suitable for outdoor installations?

A: Yes. The weatherproof (WP) rating ensures reliable operation in rain, wind, and temperature extremes. Typical outdoor applications include gate control, covered loading docks, and perimeter access points. Not rated for full submersion or high-pressure washdown.

Q: What happens to the lock during a power outage?

A: The 600WP is fail-secure: it locks when power is lost, securing the door. No emergency battery backup is built in. If your jurisdiction requires fail-safe (unlock on power loss) for life-safety compliance, request a fail-safe variant instead.

Q: What access control systems does the 600WP work with?

A: The 600WP integrates with any standard access control panel with a 12VDC or 24VDC relay output. Honeywell ProWatch, Lenel OnGuard, Genetec Security Center, Salto, and other mainstream platforms are compatible. Verify your panel has available relay capacity and correct voltage before ordering.

Q: Can I install the 600WP on a double-leaf door?

A: The 600-pound holding force supports lightweight double-leaf doors if both leaves are securely latched. Heavy or reinforced double doors may require higher force. Consult a door hardware integrator to confirm your frame and closer specifications meet the lock's force rating.

Q: What is the typical power draw of the 600WP?

A: Electromagnetic locks typically draw 1–2 amps at 12VDC during engagement. Confirm the exact specification in the datasheet before finalizing your power supply and UPS sizing. Lower power than heavy-duty or larger-format locks reduces electrical infrastructure strain.

Q: Does the 600WP require routine maintenance?

A: Minimal. Check mounting bolts annually, especially on outdoor gates. Keep the strike plate aligned and free of dirt or corrosion. Sealed weatherproof design requires no lubrication or moving-part servicing.

Jerry Tildsen
Jerry Tildsen
Perspective based on aggregated IP Security Depot and affiliated engineering team experience.

The HES 600WP sits at the practical sweet spot for warehouse and light-industrial access control. 600 pounds of holding force is enough for single-leaf doors and lightweight double-leaf gates—the real value is the weatherproof rating and the low power envelope. If you're retrofitting a loading dock or outdoor gate from mechanical locks to electronic control, the 600WP eliminates the corrosion and maintenance headaches that plague standard electromagnetic locks in damp environments.

Technical Highlights:

  • 600-pound holding force: Validates for standard single-leaf commercial doors, 1.75-inch solid-core hinged frames. Lightweight double-leaf gates work if both leaves share the load and strike plates are properly aligned. Heavier industrial or fire-rated doors may require a higher-force variant.
  • Weatherproof (WP) construction: Sealed enclosure and stainless-steel fasteners resist rain, dust, and temperature swings. Outdoor installations see 3–5x longer service life compared to non-sealed electromagnetic locks exposed to the elements.
  • Fail-secure operation: Lock defaults to secure (locked) on power loss. Aligns with most industrial security policies but conflicts with fire code if the door must unlock for emergency egress. Verify AHJ requirements before installation.
  • Low power draw (1–2A @ 12VDC typical): Minimal UPS capacity and panel relay sizing needed. On multi-door installations or facilities with tight power budgets, this reduces total infrastructure cost versus higher-amperage locks.

Deployment Considerations:

  • Strike plate alignment is critical—doors with worn hinges or out-of-square frames cause solenoid stiction and premature coil failure. Inspect and shim frames before mounting.
  • Fail-secure behavior means no access during power loss without a manual override. If your site requires hands-free emergency egress, specify a fail-safe or dual-mode lock variant and confirm life-safety codes.
  • 12VDC or 24VDC relay output from your access control panel is required. Confirm your panel has spare relay capacity and voltage matching before design review.

Deploy the 600WP where outdoor weather exposure meets routine high-traffic access—gate perimeters, covered dock entrances, and industrial production areas. It's purpose-built for these scenarios and will outlast mechanical locks in the same environment by a significant margin.

Specifications
Weight: 5.95 lb
Country of Origin: US
Environment Rating: Outdoor
Communication: TCP/IP; RS-232
Product Type: Credential
Audio: 1CH In/Out, RCA
Ethernet Rate: Speed
Storage: 4 SATA up to 32TB, eSATA, NAS, IP SAN
Camera: Name Camera Name Camera Name Camera Name
Bandwidth: 96Mbps 128Mbps 128Mbps
Warranty: 3 Year(s)
Impact Rating: IK10
Poe Power: PoE (802.3af)
Compression: H.265; H.264
Analytics: Deep Learning (DLPU)
Mount Type: Wall; Ceiling; Pole; Pendant; Corner
Dimensions: 12.4”(W)x9.1”(D)x1.8”(H) 15”(W)x12.4”(D)x1.8”(H) 15”(W)x12.4”(D)x1.8”(H) 15”(W)x12.4”(D)x1.8”(H) 15”(W)x12.4”(D)x1.8”(H) 15”(W)x12.4”(D)x1.8”(H)
Voltage DC: 24 VDC
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

HES 1200S Fail-Safe Electromagnetic Lock
Add to Cart The item has been added

HES

SKU: 1200S

HES 1200S Fail-Safe Electromagnetic Lock

Fail-safe electromagnetic lock for standard door frames, 12/24VDC

  • Defaults to locked during power loss or system failure for perimeter security
  • Compact design fits standard commercial door frames without modifications
  • Integrates with common access control systems and badge readers
$293.00 $161.99 Save $131.01
The item has been added
Free shipping over $499
$293.00 $161.99 Save $131.01
Add to cart Add to quote
HES 1200L Electromagnetic Lock
Add to Cart The item has been added

HES

SKU: 1200L

HES 1200L Electromagnetic Lock

Fail-safe electromagnetic lock for single and double doors, stays locked during power loss

  • Relay-activated operation integrates with standard access control systems without custom wiring
  • Remains locked during power interruptions, protecting secured areas when grid or system fails
  • Minimal maintenance design reduces long-term upkeep costs across multi-door commercial deployments
$357.00 $196.99 Save $160.01
The item has been added
Free shipping over $499
$357.00 $196.99 Save $160.01
Add to cart Add to quote
HES 600DLB Electromagnetic Lock
Add to Cart The item has been added

HES

SKU: 600DLB

HES 600DLB Electromagnetic Lock

12VDC electromagnetic lock for commercial access control with fail-safe egress

  • Electromagnetic strike holds doors secure when powered, releases on power loss
  • Compact design integrates with card readers, keypads, and access control systems
  • Built for high-traffic commercial facilities requiring controlled entry and emergency compliance
$518.00 $285.99 Save $232.01
The item has been added
Free shipping over $499
$518.00 $285.99 Save $232.01
Add to cart Add to quote
HES 600SDURO Electromagnetic Lock
Add to Cart The item has been added

HES

SKU: 600SDURO

HES 600SDURO Electromagnetic Lock

Heavy-duty electromagnetic lock for high-traffic access control

  • High holding force rated for industrial duty cycles and 500+ daily operations
  • Configurable fail-secure or fail-safe mode with 12VDC/24VDC external power
  • Integrates directly with card readers, keypads, and standard access control panels
$298.00 $164.99 Save $133.01
The item has been added
Free shipping over $499
$298.00 $164.99 Save $133.01
Add to cart Add to quote
HES 1200WP Electromagnetic Lock Weatherproof
Add to Cart The item has been added

HES

SKU: 1200WP

HES 1200WP Electromagnetic Lock Weatherproof

Fail-secure electromagnetic lock rated for outdoor rain, salt spray, and freeze-thaw cycles

  • Sealed IP-rated housing withstands rain, salt spray, dust on exterior doors and loading docks
  • Fail-secure solenoid keeps door locked during power loss or access control system outage
  • Fits single and double glass doors; operates -40°C to 60°C on 12VDC or 24VDC
$449.00 $247.99 Save $201.01
The item has been added
Free shipping over $499
$449.00 $247.99 Save $201.01
Add to cart Add to quote

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources