Electric Strikes
Showing Results for Electric Strikes
-
Aiphone
SKU: EL-12S
Aiphone EL-12S 12V AC Electric Door Strike
12V AC electric door strike with 4,000 N break-in resistance
- 12VAC electric door strike with 4,000N break-in resistance
- Zinc die-cast jaw and body for industrial durability
- Direct integration with Aiphone intercom systems
$130.00 $71.99 Save $58.01 -
Camden
SKU: CX-ED1420
Camden ‘Universal’ Low Profile Grade 1 ANSI Fire - CX-ED1420
- Grade 1 ANSI fire-rated per UL 1034 — compliant for egress and fire-rated door installs.
- TCP/IP connectivity enables remote unlock and audit logging without per-door hardwired strike circuits.
- Universal latch compatibility reduces SKU count and simplifies replacement across multi-building campuses.
$410.00 $246.99 Save $163.01 -
Camden
SKU: CX-EPD1299L-BK
Camden 1/2\" Surface mount Grade 1 RIM strike - CX-EPD1299L-BK
- Grade 1 rated at 1,500 lbs static strength meets ANSI/BHMA high-security requirements.
- Surface-mount, no-cut install with included metal jig reduces field labor on any frame.
- 12/24V AC/DC field-selectable with fail-safe/fail-secure mode; no rewiring required.
$700.00 $422.99 Save $277.01 -
Camden
SKU: CX-EPD1299L
Camden 1/2\" Surface mount Grade 1 RIM strike with - CX-EPD1299L
- Grade 1 ANSI/BHMA A156.31 rated with 1,500 lbs static and 70 ft-lbs dynamic holding force.
- Field-selectable 12/24V AC/DC via internal jumper eliminates rewiring across mixed-voltage sites.
- Surface-mount design with spacer plates fits 1/2"–3/4" RIM latch projection without frame cutting.
$484.48 $345.99 Save $138.49 -
Camden
SKU: CX-EPD1289-SPC
Camden 1/8\" Spacer plate for CX-EPD1289L - CX-EPD1289-SPC
- Closes frame-to-jamb gaps to preserve the CX-EPD1289L's 1,500 lb. static strength rating.
- Passive stainless steel plate installs with existing CX-EPD1289L fasteners—no extra hardware needed.
- 1/8" additive spacing corrects frame deviations common in retrofit and non-standard jamb installations.
$25.99 -
Camden
SKU: CX-ED-LIP1
Camden 1\" Lip Extension for CX-ED1079 and - CX-ED-LIP1
- Adds 1" projection to bridge frame depth gaps without relocating or rewiring the strike.
- Direct-mounts to CX-ED1079 and CX-ED-2079 using existing fastener points — no new hardware.
- Purely mechanical with zero additional current draw on the access control panel.
$27.00 $16.99 Save $10.01 -
Camden
SKU: CX-ED-LIP2
Camden 2\" Lip Extension for CX-ED1079 and - CX-ED-LIP2
- Shifts strike lip 2 inches forward to match non-standard frame rabbet depths.
- Mounts directly to CX-ED1079 or CX-ED-2079 housing using existing holes—no brackets.
- Passive metal hardware preserves full holding force and fail-safe/fail-secure operation.
$32.00 $19.99 Save $12.01 -
Camden
SKU: CX-EPD1289L
Camden 3/4\" Surface mount Grade 1 RIM strike with - CX-EPD1289L
- ANSI/BHMA Grade 1 rated at 1,500 lb static strength resists forcible entry.
- Tolerates 15 lb preload—reliable in misaligned frames or HVAC pressure zones.
- Field-selectable 12/24VDC AC/DC cuts SKU count; non-handed fits left or right.
$575.00 $337.99 Save $237.01 -
Camden
SKU: CX-EPD1289L-BK
Camden All-black finish 3/4\" surface mount - CX-EPD1289L-BK
- 12/24V AC/DC jumper-selectable voltage reduces SKU count on multi-voltage sites.
- Fail-safe/fail-secure field-configurable via jumper—no strike swap needed.
- ANSI/BHMA Grade 1 and UL10C 3-hour fire-rated; survives 500k UL cycles minimum.
$650.00 $387.99 Save $262.01 -
Camden
SKU: CX-RIM-SB
Camden Aluminum surface mounted adapter box for - CX-RIM-SB
- Eliminates strike alignment guesswork on double-door RIM assemblies via included jig.
- Compatible with CX-EPD1289L and CX-EPD1299L electric RIM strikes for predictable fit.
- Aluminum surface-mount housing (9.19" × 1.97" × 1.25") ships with full fastener kit.
$84.99 -
Camden
SKU: CX-ESP2
Camden ANSI Round 4 7/8\" X 1 1/4\" stainless steel - CX-ESP2
- ANSI 4 7/8" × 1¼" profile drops into standard strike pockets with no frame modification.
- Stainless steel housing resists corrosion, reducing maintenance cycles on high-traffic entries.
- Runs directly off access control panel relay outputs—no auxiliary power modules required.
$55.00 $33.99 Save $21.01 -
Camden
SKU: CX-ESP1
Camden ANSI Square 4 7/8\" X 1 1/4\" - CX-ESP1
- ANSI 4 7/8" × 1 1/4" form factor fits standard North American frames without custom cuts.
- TCP/IP integration enables remote unlock commands and audit logging across multi-door deployments.
- Fail-secure design keeps doors locked on power loss, meeting life-safety egress code requirements.
$55.00 $33.99 Save $21.01 -
Camden
SKU: CX-ESP1B
Camden ANSI Square 4 7/8\" x 1 1/4\" stainless steel - CX-ESP1B
- ANSI 4 7/8" x 1 1/4" footprint drops into standard commercial frames without custom milling.
- TCP/IP native communication connects directly to networked access panels, no converters needed.
- Stainless steel construction withstands corrosion in coastal, dock, and washdown environments.
$20.00 $12.99 Save $7.01 -
Camden
SKU: CM-SK336/42S
Camden CM-SK336/42S Electric Strike
- Fail-secure operation keeps the door locked on power loss, reducing breach risk.
- Integrates with standard access control panels and credential readers via conventional wiring.
- Backed by manufacturer warranty, supporting commercial and institutional deployment accountability.
$720.00 $440.99 Save $279.01 -
Camden
SKU: CX-1000/74
Camden CX-1000/74 Electric Strike Lock
Network electric strike, 24VDC fail-secure, TCP/IP control
- TCP/IP integration for centralized access control across multiple doors
- Fail-secure locking mode holds strike in locked position during power loss
- 24VDC operation with wall, ceiling, or pole mount for flexible installation
$62.00 $37.99 Save $24.01 -
Camden
SKU: CX-1000/77
Camden CX-1000/77 Electric Strike
- Fail-secure 24VDC design keeps door locked on power loss or panel fault.
- SPDT relay input requires no firmware, VMS, or network integration to deploy.
$115.00 $70.99 Save $44.01
Electric Strikes
Electric strikes replace the fixed strike plate in a door frame with an electromechanical unit that releases on command, allowing a door to be pushed or pulled open without retracting the latch bolt. They are the default door control device on most commercial access control openings.
Plan Your Deployment
- Fail-safe (unlocks on power loss) vs. fail-secure (stays locked)
- Voltage (12/24 VDC or 12/24 VAC) and current draw (holding and inrush)
- Frame material: hollow metal, aluminum, or wood
- ANSI/BHMA grade and static strength rating
- Latch monitoring, door position, and tamper signals required
What to Look For
Fail-secure is the standard on most interior commercial openings; fail-safe is required on stair doors, areas of refuge, and egress paths where local code demands free exit. Match voltage to the existing door control panel. ANSI Grade 1 strikes are rated for the heaviest commercial cycles and are recommended on high-traffic doors.
Common Deployment Scenarios
Electric strikes are used on perimeter storefronts, tenant entries, office suite doors, and interior security-zone doors. They are commonly paired with a request-to-exit sensor and door position contact to complete the opening monitoring required by audit trails.