APC by Schneider Electric SMX2200RMLV2U vs APC by Schneider Electric SRT2200XLA: Specification Comparison
Both the SMX2200RMLV2U and SRT2200XLA are APC 2200VA/120V UPS units aimed at protecting IT and network infrastructure loads in the 1.8–2.0 kW range. The key architectural divide is topology: the SMX2200RMLV2U is a Line Interactive unit in a 2U rack/tower convertible chassis, while the SRT2200XLA is a Double Conversion Online unit in a tower-only form factor. Buyers comparing these two are typically weighing protection level and rack-mount flexibility against pure power conditioning quality and runtime expandability.
In This Guide
- How do the UPS topologies and output power quality differ between these two models?
- Which model offers better runtime flexibility and battery expansion options?
- How do the two units compare on physical installation, outlet configuration, and management interfaces?
- Which should you choose: the SMX2200RMLV2U or the SRT2200XLA?
- Side-by-Side Specs
- FAQ
How do the UPS topologies and output power quality differ between these two models?
The SMX2200RMLV2U uses Line Interactive topology, which regulates voltage through AVR (automatic voltage regulation) during sags and swells without switching to battery, but transfers to battery—with a 4 ms switchover time—during outages or severe anomalies. Output waveform type is not explicitly stated in the provided specs for this model. It is rated at 2200 VA / 1980 W, yielding a 0.90 power factor.
The SRT2200XLA uses Double Conversion Online topology, meaning the connected load runs continuously from the inverter—there is zero transfer time during a power event. The output is a pure sine wave with less than 2% harmonic distortion and a 3:1 crest factor. It is rated at 2200 VA / 1800 W, for a 0.818 power factor. For loads sensitive to power quality—medical equipment, high-end servers, precision instruments—double conversion provides a fundamentally cleaner and more consistent output, at the cost of higher heat dissipation (535 Btu/h specified) and continuous inverter losses.
Which model offers better runtime flexibility and battery expansion options?
The SMX2200RMLV2U provides a baseline runtime of 10 minutes at full load and 25 minutes at half load. The replacement batteries are APCRBC117/APCRBC117J. The specs list the battery chemistry as sealed lead acid but do not specify the battery voltage or capacity in VAh. No external battery pack expansion options are listed in the provided specifications.
The SRT2200XLA ships with a 72 V, 306 VAh battery pack and a typical recharge time of 3 hours. Critically, it supports extensive external battery expansion via the SRT72BP series: one pack adds 918 VAh, scaling up to 10 packs for 6,426 VAh of additional capacity. This makes the SRT2200XLA significantly more suitable for extended runtime requirements. Baseline runtime figures at full or half load are not provided in the SRT2200XLA specs. The SMX2200RMLV2U does not list any expansion battery options in its provided specifications.
How do the two units compare on physical installation, outlet configuration, and management interfaces?
The SMX2200RMLV2U is designed for flexibility: it ships as a 2U rack/tower convertible, measuring 3.35" x 16.97" x 26.26" and weighing 84.60 lb. Its input connection is a NEMA L5-30P twist-lock plug (requiring a matching receptacle or PDU). It provides 8 output outlets—6x NEMA 5-15R and 2x NEMA 5-20R—covering both standard and 20A device connections. Management is via one Smart-Slot expansion slot, which accepts optional APC SmartSlot network management cards.
The SRT2200XLA is tower-only and not rack-mountable. It measures 17.01 in on one listed dimension (full dimensions not fully specified in the provided specs) and weighs 55.12 lb—notably lighter. Its input plug is a standard NEMA 5-20P (20A, easier to connect to standard commercial circuits). It provides 7 outlets—6x NEMA 5-20R and 1x NEMA L5-20R. It includes one free management slot compatible with APC Network Management Card 2 or 3 with environmental monitoring (optional). It also features internal automatic and manual bypass. The SMX2200RMLV2U's input L5-30P plug demands a 30A circuit; the SRT2200XLA's 5-20P requires only a standard 20A circuit.
Which should you choose: the SMX2200RMLV2U or the SRT2200XLA?
Our take: The SMX2200RMLV2U is the stronger choice when rack-mount installation is required and the facility already has a 30A NEMA L5-30P circuit available, because it fits a 2U rack slot, delivers a higher real-power output (1980 W vs. 1800 W), and protects a broader outlet mix (6x 5-15R + 2x 5-20R vs. 6x 5-20R + 1x L5-20R). Conversely, the SRT2200XLA is the stronger choice when power quality and runtime scalability are the primary requirements: its Double Conversion Online topology eliminates the 4 ms transfer gap, delivers under 2% THD output, and supports up to 10 external battery packs (up to 6,426 VAh added capacity) versus no documented expansion for the SMX2200RMLV2U. The SRT2200XLA also connects to a standard 20A NEMA 5-20P circuit, lowering installation complexity. Choose the SMX2200RMLV2U for rack-dense IT closets with 30A feeds; choose the SRT2200XLA for sensitive electronics, extended runtime deployments, or locations without rack infrastructure.
Side-by-Side Comparison
Spec-for-spec, from manufacturer data.
| Specification | APC by Schneider Electric SMX2200RMLV2U | APC by Schneider Electric SRT2200XLA |
|---|---|---|
| UPS Topology | Line Interactive | Double Conversion Online |
| VA Rating | 2200 VA | 2200 VA |
| Watt Rating | 1980 W | 1800 W |
| Power Factor | 0.90 | 0.818 |
| Input Connection | NEMA L5-30P (30A twist-lock) | NEMA 5-20P (20A standard) |
| Output Outlets | 8 (6x NEMA 5-15R + 2x NEMA 5-20R) | 7 (6x NEMA 5-20R + 1x NEMA L5-20R) |
| Transfer Time | 4 ms | 0 ms (online double conversion) |
| Output Waveform | Not specified in provided specs | Pure sine wave, <2% THD |
| Form Factor | 2U Rack/Tower Convertible | Tower only (not rack-mountable) |
| Weight | 84.60 lb | 55.12 lb |
| Runtime at Full Load | 10 minutes | Not specified in provided specs |
| Runtime at Half Load | 25 minutes | Not specified in provided specs |
| Battery Voltage | Not specified in provided specs | 72 V |
| Runtime Expandability | Not listed in provided specs | Up to 10 external SRT72BP packs (max 6,426 VAh added) |
| Management Interface | 1x Smart-Slot | 1x free slot (NMC2/NMC3 optional) |
| Typical Battery Recharge Time | 3 hours | 3 hours |
Frequently Asked Questions
Which should you choose: the SMX2200RMLV2U or the SRT2200XLA?
The SMX2200RMLV2U is the stronger choice when rack-mount installation is required and the facility already has a 30A NEMA L5-30P circuit available, because it fits a 2U rack slot, delivers a higher real-power output (1980 W vs. 1800 W), and protects a broader outlet mix (6x 5-15R + 2x 5-20R vs. 6x 5-20R + 1x L5-20R). Conversely, the SRT2200XLA is the stronger choice when power quality and runtime scalability are the primary requirements: its Double Conversion Online topology eliminates the 4 ms transfer gap, delivers under 2% THD output, and supports up to 10 external battery packs (up to 6,426 VAh added capacity) versus no documented expansion for the SMX2200RMLV2U. The SRT2200XLA also connects to a standard 20A NEMA 5-20P circuit, lowering installation complexity. Choose the SMX2200RMLV2U for rack-dense IT closets with 30A feeds; choose the SRT2200XLA for sensitive electronics, extended runtime deployments, or locations without rack infrastructure.
Can the SMX2200RMLV2U or SRT2200XLA be mounted in a standard server rack?
Only the SMX2200RMLV2U is rack-mountable. It occupies 2U in a standard rack in its rack configuration. The SRT2200XLA is specified as 'Not rack-mountable' and is designed exclusively for tower (vertical) installation.
Which model is better if I need to run my equipment for a long time during an extended outage?
The SRT2200XLA is significantly better for extended runtime. It supports up to 10 external SRT72BP battery packs, scaling its additional capacity from 918 VAh (1 pack) to 6,426 VAh (10 packs). The SMX2200RMLV2U provides 10 minutes at full load and 25 minutes at half load, and no external battery expansion options are listed in its specifications.
Does one model provide cleaner power output than the other for sensitive equipment like medical devices or high-end servers?
Yes. The SRT2200XLA's Double Conversion Online topology means connected loads always run from a continuously regenerated, pure sine wave output with less than 2% harmonic distortion and zero transfer time during a power event. The SMX2200RMLV2U uses Line Interactive topology, which has a 4 ms transfer time to battery during an outage; its output waveform type is not specified in the provided specs. For the most sensitive equipment, the SRT2200XLA offers a higher level of power conditioning.
More UPS Comparisons
- CyberPower PR2200RTXL2UC vs APC by Schneider Electric SRT2200RMXLA
- CyberPower PR2200RTXL2UC vs APC by Schneider Electric SRT2200XLA
- CyberPower PR2200RTXL2UC vs APC by Schneider Electric SRT2200RMXLA-NC
- CyberPower PR2200RTXL2UC vs APC by Schneider Electric SMT2200I
- CyberPower PR2200RTXL2UC vs CyberPower OL2K2RTHD
- CyberPower PR2200RTXL2UC vs CyberPower OL2200RTXL2U