APC by Schneider Electric SURT002 vs CyberPower PR5000LCDRTXL5U: Specification Comparison
Both the APC SURT002 and CyberPower PR5000LCDRTXL5U are 5000VA rack-mount UPS-class power devices, but there is a critical distinction: the SURT002 is an isolation transformer accessory designed to pair with an APC Smart-UPS RT, not a standalone UPS system. The PR5000LCDRTXL5U is a self-contained 5000VA UPS system with integrated battery, inverter, and AVR. A buyer evaluating these two should understand they are not equivalent devices despite sharing a VA class.
In This Guide
- Is the SURT002 a standalone UPS or a dependent accessory — and how does that affect deployment?
- How do the physical form factors and rack space requirements compare?
- What are the electrical compatibility and output specifications, and which fits standard North American or international deployments?
- Which should you choose: the SURT002 or the PR5000LCDRTXL5U?
- Side-by-Side Specs
- FAQ
Is the SURT002 a standalone UPS or a dependent accessory — and how does that affect deployment?
The APC SURT002 is explicitly an isolation transformer for use with the APC Smart-UPS RT 5000VA 230V platform. It does not contain a battery, inverter, or charger. It requires a host Smart-UPS RT unit to function and provides galvanic isolation and output conditioning downstream of that UPS. It cannot protect a load independently.
The CyberPower PR5000LCDRTXL5U is a complete, self-contained UPS system rated at 5000VA. It includes integrated sealed lead-acid batteries (16 x 12V/9Ah, user replaceable and hot swappable), a pure sine wave inverter, automatic voltage regulation (AVR), and LCD management interface. It protects connected loads without any additional host unit.
For a buyer needing a complete power protection solution, only the PR5000LCDRTXL5U qualifies as a standalone deployment. The SURT002 is a supplemental component for an existing APC Smart-UPS RT infrastructure.
How do the physical form factors and rack space requirements compare?
The APC SURT002 occupies 3U of rack space with dimensions of 17" W × 5.1" H × 26" D and weighs 125 lb. It ships as a rack-mount-only unit with no tower option listed in the provided specifications. Hard-wire 3-wire connection is required for output; no outlet strip is integrated.
The CyberPower PR5000LCDRTXL5U occupies 5U of rack space with dimensions of 17" W × 8.75" H × 24.25" D and weighs 222 lb. It supports both rack-mount and tower orientations, offering more physical flexibility. It ships with five output receptacles and uses an L6-30 input connector at 208V.
The SURT002 is lighter (125 lb vs 222 lb) and shallower (26" vs 24.25" — nearly equal) and saves 2U of rack space, but those advantages are only relevant as an add-on component, not as a replacement for a UPS system. The PR5000LCDRTXL5U's dual rack/tower orientation provides installation flexibility the SURT002 does not offer.
What are the electrical compatibility and output specifications, and which fits standard North American or international deployments?
The APC SURT002 is rated for 230V AC output and requires a compatible 230V APC Smart-UPS RT host. No input voltage range, output tolerance, frequency spec, or outlet configuration is provided in the supplied specifications. Its primary electrical function is isolation — separating the load circuit from the upstream supply galvanically — which is critical in medical, laboratory, or sensitive analog equipment environments.
The CyberPower PR5000LCDRTXL5U accepts 208VAC nominal input with a wide range of 148–254VAC, delivering 208VAC ± 5% output via pure sine wave. It is rated for North American 208V single-phase environments typical of data centers and larger IT closets using L6-30 circuits. It carries UL1778, RoHS, and ENERGY STAR certifications.
The voltage mismatch (230V vs 208V) is operationally significant: the SURT002 targets international or 230V-wired facilities, while the PR5000LCDRTXL5U targets North American 208V infrastructure. A buyer must match the unit to their facility's wiring standard.
Which should you choose: the SURT002 or the PR5000LCDRTXL5U?
Our take: The PR5000LCDRTXL5U is the stronger choice when a buyer needs a complete, self-contained 5000VA UPS system — the SURT002 is not a UPS and cannot be directly substituted for one. Three concrete spec deltas underscore this: the PR5000LCDRTXL5U includes 16 × 12V/9Ah hot-swappable batteries and a pure sine wave inverter, while the SURT002 contains no battery or inverter whatsoever; the PR5000LCDRTXL5U carries a 3-year warranty versus the SURT002's 2-year warranty; and the PR5000LCDRTXL5U meets UL1778, RoHS, and ENERGY STAR certifications where no equivalent standards are cited for the SURT002. The SURT002 is the appropriate choice only for an installer who already owns an APC Smart-UPS RT 5000VA 230V and requires downstream galvanic isolation — a medical, laboratory, or analog-sensitive use case on a 230V facility. General data-center or IT buyers on 208V North American infrastructure should evaluate the PR5000LCDRTXL5U as a standalone solution.
Side-by-Side Comparison
Spec-for-spec, from manufacturer data.
| Specification | APC by Schneider Electric SURT002 | CyberPower PR5000LCDRTXL5U |
|---|---|---|
| Device Type | Isolation Transformer (UPS accessory) | UPS System (standalone) |
| VA Rating | 5000 VA | 5000 VA |
| Integrated Battery | — | 16 × 12V/9Ah SLA, hot swappable |
| Pure Sine Wave Output | — | Yes |
| AVR | — | Yes |
| Input Voltage | — | 208VAC nominal, 148–254VAC range |
| Output Voltage | 230V AC | 208VAC ± 5% |
| Form Factor | Rack-mount only | Rack or Tower |
| Rack Height | 3U | 5U |
| Dimensions (WxHxD) | 17 × 5.1 × 26 in | 17 × 8.75 × 24.25 in |
| Weight | 125 lb | 222 lb |
| Outlet Configuration | Hard Wire 3-Wire (no outlet strip) | 5 outlets, L6-30 input |
| Operating Temperature | — | 32–104°F (0–40°C) |
| Certifications | — | UL1778, RoHS, ENERGY STAR |
| Warranty | 2 Year Limited | 3 Year Limited |
| Requires Host UPS | Yes (APC Smart-UPS RT 5000VA 230V) | No |
Frequently Asked Questions
Which should you choose: the SURT002 or the PR5000LCDRTXL5U?
The PR5000LCDRTXL5U is the stronger choice when a buyer needs a complete, self-contained 5000VA UPS system — the SURT002 is not a UPS and cannot be directly substituted for one. Three concrete spec deltas underscore this: the PR5000LCDRTXL5U includes 16 × 12V/9Ah hot-swappable batteries and a pure sine wave inverter, while the SURT002 contains no battery or inverter whatsoever; the PR5000LCDRTXL5U carries a 3-year warranty versus the SURT002's 2-year warranty; and the PR5000LCDRTXL5U meets UL1778, RoHS, and ENERGY STAR certifications where no equivalent standards are cited for the SURT002. The SURT002 is the appropriate choice only for an installer who already owns an APC Smart-UPS RT 5000VA 230V and requires downstream galvanic isolation — a medical, laboratory, or analog-sensitive use case on a 230V facility. General data-center or IT buyers on 208V North American infrastructure should evaluate the PR5000LCDRTXL5U as a standalone solution.
Can I use the APC SURT002 on its own to protect my servers without buying any other APC equipment?
No. The SURT002 is an isolation transformer, not a UPS. It has no battery, inverter, or charger. It must be paired with a compatible APC Smart-UPS RT 5000VA 230V host unit to function. Without that host UPS, it provides no power protection.
Can the CyberPower PR5000LCDRTXL5U batteries be replaced without shutting down connected equipment?
Yes. The provided specifications state the PR5000LCDRTXL5U uses 16 × 12V/9Ah sealed lead-acid batteries that are user replaceable and hot swappable, meaning battery replacement can be performed without powering down the load.
Which unit is appropriate for a North American data center wired with 208V circuits?
The CyberPower PR5000LCDRTXL5U. It accepts 208VAC nominal (range 148–254VAC) and uses an L6-30 input connector standard in North American 208V environments. The APC SURT002 is rated for 230V output and targets international or 230V-wired facilities; no 208V input compatibility is stated in the provided specifications.
More UPS Comparisons
- APC by Schneider Electric SRT5KRMXLIM vs Vertiv GXT5LI-5000MVRT3UXLN
- APC by Schneider Electric SRT5KRMXLIM vs CyberPower PR5000LCDRTXL5U
- APC by Schneider Electric SRT5KRMXLIM vs Vertiv GXT5LI-5KL630RT3UXLN
- APC by Schneider Electric SRT5KRMXLIM vs APC by Schneider Electric SRT5KRMXLT-IEC
- APC by Schneider Electric SRT5KRMXLIM vs APC by Schneider Electric SRT5KXLT-IEC
- APC by Schneider Electric SRT5KRMXLT-IEC vs Vertiv GXT5LI-5000MVRT3UXLN
UPS Buying Guides
Get a Second Opinion on Your Camera Choice
Share your site layout, coverage goals, and budget. Our team will validate the camera selection, flag anything we would change, and recommend products that match the use case.