Door Relays, Isolators, Locks, & Bolts
Showing Results for Door Relays, Isolators, Locks, & Bolts
-
HES
SKU: 600DLB
HES 600DLB Electromagnetic Lock
12VDC electromagnetic lock for commercial access control with fail-safe egress
- Electromagnetic strike holds doors secure when powered, releases on power loss
- Compact design integrates with card readers, keypads, and access control systems
- Built for high-traffic commercial facilities requiring controlled entry and emergency compliance
$518.00 $285.99 Save $232.01 -
HES
SKU: 600L
HES 600L 600-Pound Magnetic Lock with LED Indicator
600-pound magnetic lock with dual voltage and built-in LED status
- 600-pound holding force secures standard commercial doors against forced entry
- Integrated LED indicator shows lock engagement without external sensors or wiring
- Dual 12VDC/24VDC operation fits existing campus and mixed-supply power systems
$289.00 $159.99 Save $129.01 -
HES
SKU: 600LBDURO
HES 600LBDURO 600 lb Electromagnetic Lock
600 lb electromagnetic lock for high-security access control
- 600-pound holding force with 24VDC fail-safe operation
- Heavy-duty construction rated for high-traffic commercial facilities
- Compatible with standard access control systems for flexible integration
$433.00 $238.99 Save $194.01 -
HES
SKU: 600LBPCB
HES 600LBPCB 600LB Series PC Board
PC board control interface for 600LB Series electromechanical locks
- Purpose-built for 600LB Series locks; eliminates adapters and simplifies field wiring.
- Powered via 802.3af PoE, integrating directly with standard access control switches.
- RS-485 connectivity delivers real-time lock position feedback for audit and tamper detection.
$35.00 $19.99 Save $15.01 -
HES
SKU: 600LDURO
HES 600LDURO 600 Pound Electromagnetic Lock
600-pound electromagnetic lock with dual voltage and LED status
- 600 lb holding force for commercial access control doorways
- Dual voltage operation (12 or 24 VDC) integrates into existing systems
- Integrated LED indicator shows lock status for quick troubleshooting
$335.00 $184.99 Save $150.01 -
HES
SKU: 600PCB
HES 600PCB PC Board Replacement Component
Replacement PC board for HES 600 Series access control system repair
- Direct drop-in replacement for HES 600 Series boards, minimizing system downtime.
- US-manufactured PC board maintains original electrical and control specifications.
- Designed for field-level swap by integrators without full system replacement.
$30.00 $29.99 Save $0.01 -
HES
SKU: 600S
HES 600S 600 Pound Single Door Magnetic Lock
600-pound magnetic lock for single-door access control
- 600 lb holding force with fail-safe electromagnetic operation
- 24VDC powered, integrates with standard access control systems
- Compatible with single-door frames and electric strike installations
$236.00 $130.99 Save $105.01 -
HES
SKU: 600SDURO
HES 600SDURO Electromagnetic Lock
Heavy-duty electromagnetic lock for high-traffic access control
- High holding force rated for industrial duty cycles and 500+ daily operations
- Configurable fail-secure or fail-safe mode with 12VDC/24VDC external power
- Integrates directly with card readers, keypads, and standard access control panels
$298.00 $164.99 Save $133.01 -
HES
SKU: 600WP
HES 600WP Electromagnetic Lock 600lb Holding Force
600lb weatherproof electromagnetic lock for outdoor access control
- 600-pound holding force rated for commercial doors and gates
- Weatherproof construction handles rain, temperature swings, moisture exposure
- Fail-secure operation locks on power loss; 12VDC or 24VDC relay control
$325.00 $179.99 Save $145.01 -
HES
SKU: 610LM
HES 610LM Monitored Cabinet Lock
Real-time monitored cabinet lock with contact-based status reporting
- Contact detection logs all access events to integrated security panels
- Built for indoor equipment enclosures and network infrastructure cabinets
- Generates audit trail of cabinet openings for compliance verification
$241.00 $121.99 Save $119.01 -
HES
SKU: 660-24V-LBSM
HES 660-24V-LBSM Electromagnetic Cabinet Lock
24V electromagnetic cabinet lock for access-controlled server enclosures
- 24V DC operation integrates with standard access control systems
- Indoor-rated electromagnetic locking for cabinet and enclosure security
- Controlled entry mechanism for server rooms and data center installations
$242.00 $122.99 Save $119.01 -
HES
SKU: 7000-LBM
HES 7000-LBM Fail-Secure Electric Door Strike
Fail-secure electric strike for access control—locks on power loss
- 12VDC or 24VDC trigger from access control panel, standard frame mount
- Defaults to locked if power fails, eliminating cut-power security breach
- Direct integration with commercial access control systems, no relay needed
$505.00 $255.99 Save $249.01 -
HES
SKU: 7000C-630
HES 7000C-630 Complete PACS Latchbolt Electric Strike
Complete electric strike for latchbolt doors with integrated access control
- Electromagnetic strike replaces keys with credential-verified remote access control
- Purpose-built for standard latchbolt locks; no adapters or custom fabrication needed
- 12VDC operation with fail-safe design; integrates with existing control systems
In stock · Ships same business day$445.00 $224.99 Save $220.01 -
HES
SKU: 7100-310-335-00
HES 7100-310-335-00 Electric Strike Black
Black electric strike for standard and networked access control
- Compatible with both standard and networked access control systems
- 12VDC input voltage for direct integration into commercial door frames
- Indoor commercial rated with standard strike mounting configuration
$258.00 $128.99 Save $129.01 -
HES
SKU: 7100-310-628-00
HES 7100-310-628-00 Electric Strike for Aluminum Jamb
Electric strike for aluminum door frames, 12/24VDC access control
- Purpose-engineered for aluminum jambs—mounts directly, no field machining
- Standard 12/24VDC wiring integrates with card readers, keypads, intercoms
- ~500mA release draw fits within shared power budgets across multiple doors
$258.00 $128.99 Save $129.01 -
HES
SKU: 7100-315-626-00
HES 7100-315-626-00 Electric Strike Aluminum Jamb
Electromagnetic strike for aluminum jamb doors with fail-safe/secure modes
- Mounts directly to aluminum jambs with keeper plate alignment setup
- Switchable fail-safe and fail-secure operation modes for access control systems
- 12VDC electromagnetic mechanism compatible with keypad and control integration
$294.00 $146.99 Save $147.01
Door Relays, Isolators, Locks, & Bolts
Door relays, isolators, electric locks, and bolt hardware connect access control systems to physical door security. Proper selection ensures reliable operation, electrical protection, and compliance with life-safety requirements in commercial deployments.
Plan Your Deployment
- Fail-safe vs fail-secure lock configuration
- Door type and mounting surface compatibility
- Voltage requirements and power supply capacity
- Relay isolation to protect controller boards
- Local fire and building code compliance
Door Relays, Isolators, Locks, & Bolts — Engineering-Grade Door Hardware for Commercial Deployments
This category covers 338 working models of door relays, isolators, locks, & bolts sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.
What to Look For
Fail-safe versus fail-secure determines what happens during power loss. Fail-safe locks unlock on power loss (used on egress doors where life safety dominates); fail-secure locks remain locked (used on storage, server rooms, and exterior doors where security dominates). Code typically mandates fail-safe on stairwell and egress doors. Confirm with the AHJ before specifying — misapplied lock mode is a common code violation.
Strike, mortise, magnetic lock, and electrified panic hardware each have distinct installation, current draw, and code implications. Electric strikes work with most mechanical locksets and are easiest to retrofit. Magnetic locks (maglocks) provide high holding force on glass and wood doors but require dedicated REX and panic-bar interfaces for egress compliance. Verify the door's existing prep before choosing.
Power draw and inrush current dictate power supply sizing. A 5-door system with 1A peak per lock can exceed an undersized 12VDC supply at simultaneous lock-down events. Account for accessories — REX motion sensors, door-position switches, electrified levers — when sizing the supply and the battery backup required for code compliance.
Tamper switches, door-position monitoring, and request-to-exit sensors generate the audit trail your security team needs. Mechanical contact switches are cheaper; magnetic reed switches resist tampering better. Pair each door with a position switch and a REX sensor at minimum — without door-position monitoring, you can't distinguish 'authorized entry' from 'door held open after authorized entry,' which is a common compliance gap.
Key Specs in This Category
| Spec | Available Options |
|---|---|
| IP Rating | IP66, IP67 |
| Connectivity | Wired |
| Power | AC/DC, PoE |
| Type | Accessory, Controller, Monitor, Lock/Strike, Stainless Steel Endcaps, Intercom, door strike, Maglock Brackets |
| Night Vision | Yes |
Top Brands in This Category
Frequently Asked Questions
Fail-safe or fail-secure for stairwell doors?
Fail-safe is mandatory on most stairwell doors and other code-designated egress paths — the lock must release on fire alarm or power loss to allow evacuation. Fail-secure on those doors is a code violation. Confirm the local fire code and AHJ requirements; commercial buildings in the U.S. follow NFPA 101 and the International Building Code, both of which detail egress lock behavior in detail.
What current draw should I plan for electrified locks?
Typical 12VDC electric strikes draw 200-500 mA continuous, with inrush spikes of 1-2A at engagement. Magnetic locks rated for 1,200 lbs holding force draw around 500 mA continuous at 24VDC. Power supplies need to handle simultaneous lock-down current — emergency lockdown events activate all locks at once. Size the supply with at least 25% headroom and confirm battery backup runtime requirements.
Do I need a request-to-exit (REX) sensor?
Most code-compliant electrified door installations require a REX sensor to shunt the alarm during authorized egress. Without REX, every egress event registers as a forced-door alarm. PIR motion sensors are the common choice and integrate with the door controller's REX input. Mechanical push-bar REX is also acceptable for hardware that includes that switch natively.
Can I use one lock for both card and mechanical key entry?
Yes — most electrified strikes and locks allow mechanical key override on the same door. Maintaining a master key for emergency mechanical access is required by code in many jurisdictions and recommended in all. Document the master key holders carefully; an uncontrolled master key program undermines the electronic audit trail.
What's the lifespan of a magnetic lock?
Quality maglocks (Securitron M62, HES, von Duprin) typically last 15-20 years with no mechanical wear. Failure points are the connector, the armature plate-to-lock alignment, and contamination of the magnetic face. Plan for armature replacement at year 10 as a hedge against alignment drift. Strike-type locks with mechanical parts last 5-10 years before strike-plate wear becomes a reliability issue.
Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.