APC by Schneider Electric SYH2K6RMI vs APC by Schneider Electric SYH2K6RMT-P1

UPS COMPARISON

APC by Schneider Electric SYH2K6RMI vs APC by Schneider Electric SYH2K6RMT-P1: Specification Comparison

Both units are APC Symmetra RM 2KVA Scalable to 6KVA N+1 rack-mountable UPS power arrays — the same product line and the same 2kVA class. The critical differentiator is regional electrical standard: the SYH2K6RMI is configured for international 230V markets, while the SYH2K6RMT-P1 targets North American 208V/120V infrastructure. This comparison examines input/output voltage compatibility, physical footprint and weight, and the specification gaps that affect purchasing confidence for IT buyers and installers selecting a scalable UPS for rack environments.



Which unit matches your facility's electrical infrastructure — 230V international or 208V North American?

The SYH2K6RMI accepts 230V input and delivers 230V output, making it suited for international markets (Europe, Middle East, Asia-Pacific) where single-phase 230V is standard. The SYH2K6RMT-P1 accepts 208V input via a NEMA L6-30P 30A plug and delivers 120V output, which aligns with North American data center power distribution — specifically 208V three-phase feeds stepped down to 120V outlets common in US rack deployments.

These two units are not interchangeable on a circuit level. Installing the SYH2K6RMI on a 208V North American feed, or the SYH2K6RMT-P1 on a 230V international feed, would be an incompatible mismatch. Buyers must confirm facility voltage before selecting. The SYH2K6RMT-P1's NEMA L6-30P input connection type is specified; the SYH2K6RMI's input connector type is not provided in the available specs.


What rated power and battery specifications does each unit deliver?

The SYH2K6RMI specifies a rated output of 2000VA / 1400W, giving a power factor of 0.70. It also lists battery type as lead-acid. The SYH2K6RMT-P1 provides no rated VA or wattage figures in the supplied specifications, and no battery type is listed. For the SYH2K6RMT-P1, buyers cannot confirm power capacity or battery chemistry from the available data alone.

The SYH2K6RMI's 1400W / 2000VA rating is a concrete planning figure for load calculations. The absence of equivalent data for the SYH2K6RMT-P1 is a meaningful gap: installers sizing UPS capacity for protected loads cannot rely on the specs as provided and should consult APC's official datasheet for the SYH2K6RMT-P1 before committing to a deployment.


How do the two units compare in rack space, dimensions, and weight?

The SYH2K6RMI lists a single dimension of 35.6 cm and a weight of 74.55 kg (approximately 164 lb). The SYH2K6RMT-P1 lists a dimension of 44.5 cm (17.52 in) and a substantially higher weight of 117.73 kg (259.55 lb). Both are described as rack-mountable, but neither specification set provides a complete depth-width-height breakdown or a rack unit (U) height figure.

The SYH2K6RMT-P1 outweighs the SYH2K6RMI by approximately 43 kg (95 lb) — a 58% difference. This has direct implications for rack weight load ratings, floor load capacity, and the number of personnel or mechanical aids required for installation. Data center facilities with strict per-rack weight limits should verify structural ratings before deploying the SYH2K6RMT-P1. Both units are listed in black finish.


Which should you choose: the SYH2K6RMI or the SYH2K6RMT-P1?

Our take: The SYH2K6RMI is the stronger choice when your facility runs 230V international single-phase power and you require confirmed power output specifications for load planning. Key spec deltas: (1) Input/output voltage — SYH2K6RMI is 230V in/230V out versus SYH2K6RMT-P1's 208V in/120V out, making each unit region-specific and non-interchangeable; (2) Rated power — SYH2K6RMI is documented at 2000VA/1400W with a 0.70 power factor, while the SYH2K6RMT-P1 has no rated power figures in the provided specs; (3) Weight — SYH2K6RMT-P1 is significantly heavier at 117.73 kg versus 74.55 kg for the SYH2K6RMI, demanding greater structural attention. Choose the SYH2K6RMT-P1 for North American 208V/120V data center racks, but verify its VA/W rating and battery specs via APC's official datasheet before finalizing the design.


Side-by-Side Comparison

Spec-for-spec, from manufacturer data.

SpecificationAPC by Schneider Electric SYH2K6RMIAPC by Schneider Electric SYH2K6RMT-P1
SKUSYH2K6RMISYH2K6RMT-P1
Product LineSymmetra RM 2KVA Scalable to 6KVA N+1Symmetra RM 2KVA Scalable to 6KVA N+1
Device TypePower Array / UPS (Rack-mountable)Uninterruptible Power Supply (Rack-mountable)
Main Input Voltage230 V208 V
Main Output Voltage230 V120 V
Input Connection TypeNEMA L6-30P 30 A
Rated Power (VA)2000 VA
Rated Power (W)1400 W
Power Factor0.70
Wave TypeSine wave
Battery TypeLead-acid
Mounting ModeRack-mountableRack-mountable
ColorBlackBlack
Dimension (single axis provided)35.6 cm44.5 cm (17.52 in)
Weight74.55 kg (~164 lb)117.73 kg (259.55 lb)
Target Market / Voltage RegionInternational (230V)North American (208V/120V)

Frequently Asked Questions

Which should you choose: the SYH2K6RMI or the SYH2K6RMT-P1?

The SYH2K6RMI is the stronger choice when your facility runs 230V international single-phase power and you require confirmed power output specifications for load planning. Key spec deltas: (1) Input/output voltage — SYH2K6RMI is 230V in/230V out versus SYH2K6RMT-P1's 208V in/120V out, making each unit region-specific and non-interchangeable; (2) Rated power — SYH2K6RMI is documented at 2000VA/1400W with a 0.70 power factor, while the SYH2K6RMT-P1 has no rated power figures in the provided specs; (3) Weight — SYH2K6RMT-P1 is significantly heavier at 117.73 kg versus 74.55 kg for the SYH2K6RMI, demanding greater structural attention. Choose the SYH2K6RMT-P1 for North American 208V/120V data center racks, but verify its VA/W rating and battery specs via APC's official datasheet before finalizing the design.

Can I use the SYH2K6RMI or SYH2K6RMT-P1 interchangeably in my data center?

No. The SYH2K6RMI is designed for 230V input/output (international markets), while the SYH2K6RMT-P1 is designed for 208V input and 120V output with a NEMA L6-30P 30A plug (North American data centers). Using either unit on an incompatible voltage feed would be an electrical mismatch. Select the unit that matches your facility's power distribution standard.

What is the wattage rating of the SYH2K6RMT-P1?

The provided specifications for the SYH2K6RMT-P1 do not include a rated wattage or VA figure. Only the SYH2K6RMI has confirmed ratings of 2000VA and 1400W in the supplied data. For the SYH2K6RMT-P1, consult APC's official product datasheet to obtain the power capacity before sizing it for a protected load.

Is the SYH2K6RMT-P1 significantly heavier than the SYH2K6RMI, and does it matter for rack installation?

Yes — the SYH2K6RMT-P1 weighs 117.73 kg (259.55 lb) versus the SYH2K6RMI at 74.55 kg (approximately 164 lb), a difference of roughly 43 kg (95 lb). This 58% weight disparity is material for rack load ratings, raised-floor weight limits, and installation labor. Verify your rack and floor load specifications before deploying the SYH2K6RMT-P1.



Get a Second Opinion on Your Camera Choice