Middle Atlantic S500R vs Vertiv GXT5-500LVRT2UXL: Specification Comparison
Both units are 500VA rack-mount UPS systems targeting AV/IT closets and light network infrastructure. The Middle Atlantic UPS-S500R is a 1U line-interactive unit aimed at AV rack integrators who need compact, affordable battery backup, while the Vertiv Liebert GXT5-500LVRT2UXL is a 2U online double-conversion unit targeting IT buyers who require zero transfer time and tight voltage regulation. A buyer choosing between them is weighing installation simplicity and footprint against power quality, runtime visibility, and remote management.
In This Guide
- What UPS topology does each unit use, and how does that affect power quality during an outage?
- How much runtime can each unit deliver, and what monitoring or management options are available?
- How do the two units compare on rack space, physical dimensions, and installation requirements?
- Which should you choose: the S500R or the GXT5-500LVRT2UXL?
- Side-by-Side Specs
- FAQ
What UPS topology does each unit use, and how does that affect power quality during an outage?
The Middle Atlantic UPS-S500R does not specify its topology (line-interactive vs. standby vs. online) in the provided specifications. Its surge protection is listed as 'Basic,' and no transfer time is stated, which leaves a buyer unable to confirm whether connected equipment ever experiences a transfer gap during a utility event.
The Vertiv GXT5-500LVRT2UXL is explicitly rated as Online Double Conversion, meaning the load runs continuously off the inverter and never experiences a transfer switching event — the spec sheet states 'zero transfer time.' Output is a pure sinewave regulated to ±3% regardless of input fluctuations, across an exceptionally wide input operating range of 60–150VAC without switching to battery. This topology is the highest available in commercial UPS design.
For equipment that is sensitive to voltage sags, waveform distortion, or switching transients — such as network switches with capacitor-heavy PSUs or medical/industrial gear — the Vertiv's online topology provides a materially higher level of protection than what the S500R's specs can confirm.
How much runtime can each unit deliver, and what monitoring or management options are available?
The Vertiv GXT5-500LVRT2UXL provides specified runtime estimates: 15–18 minutes at 50% load (250W) and 8–10 minutes at 80% load (400W). The battery is hot-swappable sealed lead-acid (VRLA), meaning replacement does not require a scheduled maintenance window or load shutdown. A color LCD displays real-time load percentage, estimated runtime, input/output voltage, and battery health.
The Middle Atlantic UPS-S500R provides no runtime estimate in its specifications. Battery type, hot-swap capability, and any display or indicators are not specified.
For management connectivity, the Vertiv offers USB, RS485, RS232, and an optional RDU101 network card slot for SNMP/network integration. It is compatible with PowerAlert, VMware, Windows Server, and Linux shutdown daemons. The S500R lists no communication ports, no management software compatibility, and no network card option in its specifications. Buyers who need supervised shutdown or remote monitoring have a clear data point only for the Vertiv.
How do the two units compare on rack space, physical dimensions, and installation requirements?
The Middle Atlantic UPS-S500R occupies 1U (1.73 in H × 19 in W × 9.06 in D) and ships at 20.4 lbs. It supports rack mounting depth between 19 in and 32 in, uses a 10 ft input cord (NEMA type not specified), and requires two mounting points. Its compact 9.06-inch depth is a significant advantage in shallow AV racks or wall-mount enclosures where depth is constrained.
The Vertiv GXT5-500LVRT2UXL occupies 2U (3.5 in H × 17 in W × 16 in D) and weighs approximately 28 lbs. It is convertible between rack and tower orientations. Its 16-inch depth fits standard 19-inch EIA data racks but will not fit the shallow AV racks the S500R is designed for. The input cord is 6 ft versus the S500R's 10 ft.
The S500R's 1U / 9.06 in depth profile is a direct installation advantage in AV and shallow-rack environments. The Vertiv's 2U / 16 in depth and 7.6 lb weight premium reflect its larger battery bank and online conversion circuitry, which are the source of its runtime and power-quality advantages. Rack space budget and available depth should be confirmed before either unit is specified.
Which should you choose: the S500R or the GXT5-500LVRT2UXL?
Our take: The GXT5-500LVRT2UXL is the stronger choice when power quality, confirmed runtime, and remote management are the primary requirements. Its online double-conversion topology delivers zero-transfer-time protection and ±3% output regulation — specs the S500R does not provide — making it the defensible choice for IT switching gear, servers, or any load intolerant of sags or switching transients. Runtime is specified at 15–18 minutes at 50% load versus no stated runtime for the S500R. Hot-swappable VRLA batteries, a color LCD, USB/RS485/RS232 ports, and an optional SNMP card slot add serviceability and supervisory shutdown capability the S500R lacks entirely. The S500R's advantage is physical: 1U height and only 9.06 inches of depth make it the only option in shallow AV racks or 1U-constrained enclosures. Specify the S500R for AV rack builds where depth and rack-unit count dominate the decision; specify the GXT5-500LVRT2UXL for IT closets where uptime quality and manageability matter more than rack depth.
Side-by-Side Comparison
Spec-for-spec, from manufacturer data.
| Specification | Middle Atlantic S500R | Vertiv GXT5-500LVRT2UXL |
|---|---|---|
| VA Capacity | 500VA | 500VA |
| Watt Capacity | — | 500W |
| Topology | Not specified | Online Double Conversion |
| Transfer Time | Not specified | Zero (continuous online) |
| Output Waveform | Not specified | Pure Sinewave |
| Output Voltage Regulation | Not specified | ±3% |
| Input Voltage Range | Not specified | 60–150VAC (no battery transfer) |
| Form Factor / Rack Units | 1U Rack | 2U Rack/Tower Convertible |
| Dimensions (H × W × D) | 1.73 × 19 × 9.06 in | 3.5 × 17 × 16 in |
| Weight | 20.4 lbs (9.3 kg) | ~28 lbs |
| Input Cord Length | 10 ft (3.1 m) | 6 ft |
| Total Outlets | 6 | 6 × NEMA 5-15R (4 programmable, 2 non-programmable) |
| Battery Type / Hot-Swap | Not specified | VRLA, Hot-Swappable |
| Runtime at 50% Load | Not specified | 15–18 minutes |
| Runtime at 80% Load | Not specified | 8–10 minutes |
| Management Ports | Not specified | USB, RS485, RS232; optional SNMP card |
| Display | Not specified | Color LCD (load, runtime, voltage, battery health) |
| Efficiency | Not specified | >92% at 50% load (Energy Star 2.0) |
| Certifications | UL Listed, FCC | UL 1778 4th ed., CSA 22.2 No. 107.1, Energy Star 2.0, RoHS2, REACH, WEEE |
| TAA Compliant | No | — |
| Warranty | Not specified | 3-year advanced replacement (UPS and battery, next-business-day) |
Frequently Asked Questions
Which should you choose: the S500R or the GXT5-500LVRT2UXL?
The GXT5-500LVRT2UXL is the stronger choice when power quality, confirmed runtime, and remote management are the primary requirements. Its online double-conversion topology delivers zero-transfer-time protection and ±3% output regulation — specs the S500R does not provide — making it the defensible choice for IT switching gear, servers, or any load intolerant of sags or switching transients. Runtime is specified at 15–18 minutes at 50% load versus no stated runtime for the S500R. Hot-swappable VRLA batteries, a color LCD, USB/RS485/RS232 ports, and an optional SNMP card slot add serviceability and supervisory shutdown capability the S500R lacks entirely. The S500R's advantage is physical: 1U height and only 9.06 inches of depth make it the only option in shallow AV racks or 1U-constrained enclosures. Specify the S500R for AV rack builds where depth and rack-unit count dominate the decision; specify the GXT5-500LVRT2UXL for IT closets where uptime quality and manageability matter more than rack depth.
Can the S500R or GXT5-500LVRT2UXL fit in a shallow AV rack that is only 12–14 inches deep?
Only the Middle Atlantic UPS-S500R is specified for shallow installations — its depth is 9.06 inches and it supports rack mounting depths as short as 19 inches. The Vertiv GXT5-500LVRT2UXL is 16 inches deep and is designed for standard 19-inch EIA data racks. No shallow-rack depth rating is provided for the Vertiv in the available specifications.
Which unit is better for protecting a small network switch or NVR that cannot tolerate power interruptions?
The Vertiv GXT5-500LVRT2UXL is the stronger choice for that application. Its online double-conversion topology means there is zero transfer time — the load never sees a switching gap. Output is a regulated pure sinewave held within ±3% even while input voltage swings from 60V to 150VAC. The Middle Atlantic UPS-S500R does not specify its topology, transfer time, or output waveform regulation in the provided specifications, so those protections cannot be confirmed.
Does either unit support network management or automatic server shutdown?
The Vertiv GXT5-500LVRT2UXL does: it includes USB, RS485, and RS232 ports plus an optional RDU101 network card slot for SNMP integration, and is compatible with PowerAlert, VMware, Windows Server, and Linux shutdown daemons. The Middle Atlantic UPS-S500R lists no communication ports, management software compatibility, or network card option in the provided specifications.
More UPS Comparisons
- Vertiv GXT5-500LVRT2UXL vs APC by Schneider Electric SUA500PDR-H
- Vertiv GXT5-500LVRT2UXL vs APC by Schneider Electric BE500G3
- Vertiv GXT5-500LVRT2UXL vs APC by Schneider Electric SCL500RM1UC
- Vertiv GXT5-500LVRT2UXL vs APC by Schneider Electric SCL500RMI1UC
- APC by Schneider Electric SUA500PDR-H vs Middle Atlantic S500R
- APC by Schneider Electric SUA500PDR-H vs APC by Schneider Electric BE500G3
UPS Buying Guides
Get a Second Opinion on Your Camera Choice
Share your site layout, coverage goals, and budget. Our team will validate the camera selection, flag anything we would change, and recommend products that match the use case.