Exit Buttons
Showing Results for Exit Buttons
-
Camden
SKU: CM-6050
Camden Red Push To Lock Key To Release N/O \& N/C - CM-6050
- Push-to-lock solenoid with key-to-release override ensures code-compliant emergency egress.
- Dual N/O and N/C contacts support both fail-secure and fail-safe configurations in one unit.
- 30VDC solenoid integrates directly with standard commercial access control panels and door controllers.
$214.00 $131.99 Save $82.01 -
Camden
SKU: CM-6030
Camden Red Push To Lock Key To Release N/O Maintained - CM-6030
- 30VDC rating integrates directly with standard commercial access control panels.
- N/O maintained contact defaults to locked state on power loss—no backup battery needed.
- Key-to-release override enables manual egress without power for life-safety compliance.
$203.00 $124.99 Save $78.01 -
Camden
SKU: CM-120G
Camden Rubber gasket for any stainless steel single - CM-120G
- Rubber gasket seals single-gang SS faceplate against rain and dust ingress.
- Replaces degraded seals in 10–15 minutes; no adhesive mixing or cure time required.
- Compatible with CM-120 Series 24VDC Wiegand keypads supporting up to 999 users.
$8.00 $4.99 Save $3.01 -
Camden
SKU: CM-420RPTE
Camden Single gang N/O and N/C contacts Red button - CM-420RPTE
- Dual N/O and N/C contacts enable strike activation and alarm supervision in one device.
- Accepts 12V or 24V DC, compatible with standard access control power supplies and solenoids.
- Single-gang ABS housing retrofits directly into existing electrical boxes with no adapters.
In stock · Ships same business day$124.00 $76.99 Save $47.01 -
Camden
SKU: CM-1000/21
Camden Single gang neoprene gasket for Camden push - CM-1000/21
- Neoprene construction seals against moisture and dust in outdoor deployments.
- Direct single-gang drop-in replacement requires no hardware modification.
- Rated for 30VDC Camden push button assemblies, maintaining existing infrastructure.
$9.00 $5.99 Save $3.01 -
Camden
SKU: CM-450RL-7724-CPC
Camden Single gang Push/Pull N/O \& N/C - CM-450RL-7724-CPC
- Dual N/O and N/C contact blocks fire from one press, eliminating external relay stages.
- 6A @ 30V rating drives EM strikes and solenoid locks on 12–24V AC/DC without amplification.
- Free-spinning 18-gauge stainless button resists jamming and abuse in high-traffic corridors.
$191.00 $116.99 Save $74.01 -
Camden
SKU: CM-450R
Camden Single gang Push/Pull N/O \& N/C Stainless - CM-450R
- Dual N/O and N/C contacts fire simultaneously, eliminating external relay logic.
- 18-gauge stainless steel construction meets NEMA 4X rating for washdown and salt-air.
- Free-spinning vandal-resistant button installs in any standard single-gang wall box.
$133.00 $81.99 Save $51.01 -
Camden
SKU: CV-110SPK
Camden Slim-line stand alone prox. reader \& keypad - CV-110SPK
- Dual-protocol output (OSDP + Wiegand) integrates with modern and legacy panels.
- Reads HID 37-bit and AWID 34-bit prox formats; supports up to 2,000 users.
- Standalone design consolidates reader and keypad into one device for single-door installs.
$290.99 -
Camden
SKU: CM-1000/45
Camden SPDT maintained contact switch 6 A @ 125 V 3 - CM-1000/45
- SPDT maintained contacts hold state without coil power, eliminating idle heating.
- Dual rating (6A/125VAC, 3A/30VDC) covers both legacy DC strikes and 120VAC loads.
- TCP/IP interface enables remote status monitoring without dedicated hardwired relay racks.
$51.00 $31.99 Save $19.01 -
Camden
SKU: CM-1000/40
Camden SPDT momentary contact switch, 6 A @ 125 VAC, 3 A @ 30 VDC
SPDT momentary switch for door strikes and locks, TCP/IP networked
- 6 A @ 125 VAC / 3 A @ 30 VDC rated for solenoid strikes and relays
- TCP/IP enabled integration with networked access control systems
- SPDT momentary contact operation for electronic lock and strike control
$47.00 $28.99 Save $18.01 -
Camden
SKU: CM-5085GPTE
Camden Spring Return DPST 1-60 sec Pneumatic Time - CM-5085GPTE
- Field-adjustable 1–60 sec pneumatic delay eliminates separate electrical timers.
- DPST contacts at 24VDC/6A drive magnetic strikes or solenoids without added relays.
- Mechanical spring return resets on power loss, preventing stuck contacts at egress doors.
In stock · Ships same business day$383.00 $236.99 Save $146.01 -
Camden
SKU: CM-5085RPTE
Camden Spring Return DPST 1-60 sec Pneumatic Time - CM-5085RPTE
- DPST contacts deliver simultaneous NO and NC switching from a single actuator at 24VDC/6A.
- Mechanical pneumatic timer adjusts 1–60 sec with no panel power required for timing cycles.
- Rated 1,000,000 activation cycles with auto spring-return—no manual reset in high-traffic egress.
In stock · Ships same business day$383.00 $213.99 Save $169.01 -
Camden
SKU: CM-4085RPTE
Camden Spring Return DPST 1-60 sec Pneumatic Timer - CM-4085RPTE
- DPST configuration switches two independent circuits simultaneously from one activation.
- 1–60 sec adjustable pneumatic delay integrates directly into 24VDC access control rails.
- Spring-return mechanism fails safe to deactivated state on power or air interruption.
$383.00 $230.99 Save $152.01 -
Camden
SKU: CM-7085
Camden Spring Return, DPST 1-60 SEC Pneumatic Time Delay, (Requires...
Adjustable pneumatic time delay 1-60 sec, DPST switch for access control
- 1–60 second adjustable delay with spring return pneumatic actuation at 24VDC
- DPST configuration integrates with HID credential and TCP/IP networked systems
- Pneumatic timing mechanism operates independent of electrical supply variations
$321.00 $196.99 Save $124.01 -
Camden
SKU: CM-1000/35
Camden SPST maintained contact (on/off) switch 6 A - CM-1000/35
- Maintained SPST output latches on/off, eliminating relay chatter on strikes and door-holds.
- Rated 6A@125VAC, 3A@250VAC, and 30VDC—one switch spans low-voltage and line-voltage installations.
- Mortise cylinder interface fits 1", 1-1/8", or 1-1/4" cylinders with no set screws required.
$27.00 $16.99 Save $10.01 -
Camden
SKU: CM-1000/37
Camden SPST maintained contact switch heavy duty 15 - CM-1000/37
- Maintained 15A/30 VDC SPST contact holds closed after key turn—no continuous key pressure needed.
- 1/4" die-cast aluminum housing with rubber gasket supports indoor or outdoor wall and pole mounting.
- Pre-wired 18 AWG color-coded leads with heat-shrink sleeves enable direct relay or strike controller wiring.
$41.00 $25.99 Save $15.01
Exit Buttons
Exit buttons, also known as request-to-exit (REX) devices, allow occupants to safely unlock doors from the secured side. Proper selection ensures reliable operation, life-safety compliance, and smooth integration with your access control system.
Plan Your Deployment
- Fail-safe vs fail-secure door configuration
- Door type and mounting location
- Integration with controller inputs and timing rules
- Local fire and life-safety code compliance
- Durability and vandal-resistant requirements
Exit Buttons — Engineering-Grade Door Hardware for Commercial Deployments
This category covers 105 working models of exit buttons sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.
What to Look For
Fail-safe versus fail-secure determines what happens during power loss. Fail-safe locks unlock on power loss (used on egress doors where life safety dominates); fail-secure locks remain locked (used on storage, server rooms, and exterior doors where security dominates). Code typically mandates fail-safe on stairwell and egress doors. Confirm with the AHJ before specifying — misapplied lock mode is a common code violation.
Strike, mortise, magnetic lock, and electrified panic hardware each have distinct installation, current draw, and code implications. Electric strikes work with most mechanical locksets and are easiest to retrofit. Magnetic locks (maglocks) provide high holding force on glass and wood doors but require dedicated REX and panic-bar interfaces for egress compliance. Verify the door's existing prep before choosing.
Power draw and inrush current dictate power supply sizing. A 5-door system with 1A peak per lock can exceed an undersized 12VDC supply at simultaneous lock-down events. Account for accessories — REX motion sensors, door-position switches, electrified levers — when sizing the supply and the battery backup required for code compliance.
Tamper switches, door-position monitoring, and request-to-exit sensors generate the audit trail your security team needs. Mechanical contact switches are cheaper; magnetic reed switches resist tampering better. Pair each door with a position switch and a REX sensor at minimum — without door-position monitoring, you can't distinguish 'authorized entry' from 'door held open after authorized entry,' which is a common compliance gap.
Key Specs in This Category
| Spec | Available Options |
|---|---|
| Power | AC/DC |
| Type | Lock/Strike, Reader, Switch, Accessory, Credential, Controller, Diecast Aluminum Enclosure, 3-Button Control Station |
Top Brands in This Category
Frequently Asked Questions
Fail-safe or fail-secure for stairwell doors?
Fail-safe is mandatory on most stairwell doors and other code-designated egress paths — the lock must release on fire alarm or power loss to allow evacuation. Fail-secure on those doors is a code violation. Confirm the local fire code and AHJ requirements; commercial buildings in the U.S. follow NFPA 101 and the International Building Code, both of which detail egress lock behavior in detail.
What current draw should I plan for electrified locks?
Typical 12VDC electric strikes draw 200-500 mA continuous, with inrush spikes of 1-2A at engagement. Magnetic locks rated for 1,200 lbs holding force draw around 500 mA continuous at 24VDC. Power supplies need to handle simultaneous lock-down current — emergency lockdown events activate all locks at once. Size the supply with at least 25% headroom and confirm battery backup runtime requirements.
Do I need a request-to-exit (REX) sensor?
Most code-compliant electrified door installations require a REX sensor to shunt the alarm during authorized egress. Without REX, every egress event registers as a forced-door alarm. PIR motion sensors are the common choice and integrate with the door controller's REX input. Mechanical push-bar REX is also acceptable for hardware that includes that switch natively.
Can I use one lock for both card and mechanical key entry?
Yes — most electrified strikes and locks allow mechanical key override on the same door. Maintaining a master key for emergency mechanical access is required by code in many jurisdictions and recommended in all. Document the master key holders carefully; an uncontrolled master key program undermines the electronic audit trail.
What's the lifespan of a magnetic lock?
Quality maglocks (Securitron M62, HES, von Duprin) typically last 15-20 years with no mechanical wear. Failure points are the connector, the armature plate-to-lock alignment, and contamination of the magnetic face. Plan for armature replacement at year 10 as a hedge against alignment drift. Strike-type locks with mechanical parts last 5-10 years before strike-plate wear becomes a reliability issue.
Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.