Middle Atlantic FWD-CBS-1.5KVA-B27 vs Middle Atlantic OL1500R-2: Specification Comparison
Both the Middle Atlantic FWD-CBS-1.5KVA-B27 and the OL1500R-2 (sold as UPX-RLNK-OL1500R-2) are 1500VA/1350W rack-mount UPS units from Middle Atlantic's power protection lineup, targeting AV, security, and IT infrastructure installations. Both share the same VA rating, input/output voltage range, cord length, receptacle type, and operating temperature range, making them a legitimate cross-shop for integrators evaluating 1.5kVA rack UPS options. The primary differentiators are UPS topology, physical form factor, and rack integration depth.
In This Guide
- Which UPS topology — Line Interactive or Online Double-Conversion — best fits the connected load?
- How do the physical footprint and rack integration profiles differ, and which fits the target enclosure?
- What outlet control and remote management capabilities does each unit provide?
- Which should you choose: the FWD-CBS-1.5KVA-B27 or the OL1500R-2?
- Side-by-Side Specs
- FAQ
Which UPS topology — Line Interactive or Online Double-Conversion — best fits the connected load?
The FWD-CBS-1.5KVA-B27 uses a Line Interactive topology with MOV-based surge protection. In line-interactive designs, the inverter conditions power and corrects voltage sags/swells without switching to battery; the transfer to battery occurs only when input falls outside the correctable range. This suits loads that can tolerate brief transfer times and where minor input disturbances are the primary threat.
The OL1500R-2 uses an Online (double-conversion) topology. In online designs, the load runs continuously from the inverter, which is fed by a rectifier from AC input; the battery floats on the DC bus. This means zero transfer time to battery and complete isolation of the load from all input anomalies — frequency variation, harmonic distortion, voltage spikes — not just sags. The OL1500R-2's topology is Energy Star 2.0 certified and cTUVus listed per the provided specs; no equivalent certifications are listed for the FWD-CBS-1.5KVA-B27.
For sensitive network equipment, IP cameras, or NVRs where any input aberration can cause data corruption or reboot, the online topology of the OL1500R-2 provides a higher level of power conditioning. For standard AV or security panel loads where cost and efficiency matter more than zero-transfer-time isolation, the line-interactive FWD-CBS-1.5KVA-B27 is a viable fit.
How do the physical footprint and rack integration profiles differ, and which fits the target enclosure?
The FWD-CBS-1.5KVA-B27 occupies 2 RU at 7.42 in (18.9 cm) H × 23 in W × 27 in (68.6 cm) D and ships at 145 lbs (65.8 kg). It is designed for Middle Atlantic's BGR series enclosures and carries a 1100 lb (499 kg) weight capacity rating — indicating it serves as a structural element within a BGR rack, not merely a plug-in UPS. Mounting hardware is included. The 23-inch width is non-standard for EIA 19-inch racks.
The OL1500R-2 occupies a standard 1U (3.5 in / 8.9 cm H) footprint at 19 in (48.3 cm) W × 16 in (40.6 cm) D, weighing 44.7 lbs (20.3 kg) with a shipping weight of 51.85 lbs (23.5 kg). It specifies 4 mounting points and a mounting depth range of 22–34 in (55.9–86.4 cm), making it compatible with standard 2-post or 4-post 19-inch EIA racks. It is substantially shallower (16 in vs 27 in) and lighter (44.7 lbs vs ~132 lbs estimated unit weight).
The FWD-CBS-1.5KVA-B27 is purpose-built for Middle Atlantic BGR series furniture and is not a standard EIA-rack device. The OL1500R-2 fits any standard 19-inch rack with adequate depth. Buyers must confirm enclosure compatibility before specifying the FWD-CBS-1.5KVA-B27.
What outlet control and remote management capabilities does each unit provide?
The FWD-CBS-1.5KVA-B27 lists network enablement as available 'with UPX-RLNK-CARD,' indicating that network management is an optional add-on card, not included. Outlet bank control is referenced in the specs ('Bank: Outlet Count'; 'Number of Circuits: Yes'), but specific outlet count and individual outlet control capability are not enumerated in the provided specifications.
The OL1500R-2 is sold as 'UPX-RLNK-OL1500R-2,' with 'UPX-RLNK' indicating the network card is bundled in this SKU. It specifies 8 outlets and an Outlet Control Type of 'Bank,' meaning outlets are grouped and switchable by bank rather than individually. Network-based bank-level outlet control is therefore included out of the box with this SKU.
For deployments requiring remote reboot of connected devices or load shedding without a site visit, the OL1500R-2 SKU includes the network management card. The FWD-CBS-1.5KVA-B27 requires the UPX-RLNK-CARD accessory to achieve comparable network management; without it, management is local only. Buyers should confirm whether a base FWD-CBS-1.5KVA-B27 SKU (without the card) is available at a lower price point if network management is not required.
Which should you choose: the FWD-CBS-1.5KVA-B27 or the OL1500R-2?
Our take: The OL1500R-2 is the stronger choice when power quality and remote management are the primary requirements in a standard 19-inch rack environment. Its Online double-conversion topology eliminates all transfer time (versus a finite transfer time on the line-interactive FWD-CBS-1.5KVA-B27), delivers complete input isolation, and carries Energy Star 2.0 and cTUVus certifications not listed for the FWD-CBS-1.5KVA-B27. It is also substantially smaller (1U / 16 in deep vs 2U / 27 in deep) and lighter (44.7 lbs vs ~132 lbs estimated), and the UPX-RLNK-OL1500R-2 SKU bundles network bank-outlet control for 8 outlets without an add-on card. Specify the FWD-CBS-1.5KVA-B27 when the installation is built around a Middle Atlantic BGR series enclosure and the 23-inch-wide, 2RU structural integration, 1100 lb weight capacity, and BGR platform compatibility are required — capabilities the OL1500R-2 does not provide.
Side-by-Side Comparison
Spec-for-spec, from manufacturer data.
| Specification | Middle Atlantic FWD-CBS-1.5KVA-B27 | Middle Atlantic OL1500R-2 |
|---|---|---|
| VA Rating | 1500VA | 1500VA |
| Watt Rating | 1350W | 1350W |
| UPS Topology | Line Interactive | Online (Double-Conversion) |
| Input Voltage | 120 VAC | Not specified |
| AC Output Voltage | 110–127 VAC | 110–127 VAC |
| DC Output Voltage | 48 VDC | — |
| Input Current | 15A | 15A |
| Plug Type | NEMA 5-15P | NEMA 5-15P |
| Receptacle Type | NEMA 5-15R | NEMA 5-15R |
| Outlet Count | Not specified | 8 |
| Outlet Control | Bank (with UPX-RLNK-CARD add-on) | Bank (included in SKU) |
| Surge Protection | MOV | — |
| Rack Units | 2U | 1U |
| Width | 23 in (non-standard) | 19 in (EIA standard) |
| Depth | 27 in (68.6 cm) | 16 in (40.6 cm) |
| Height | 7.42 in (18.9 cm) | 3.5 in (8.9 cm) |
| Unit Weight | Not specified separately | 44.7 lbs (20.3 kg) |
| Shipping Weight | 145 lbs (65.8 kg) | 51.85 lbs (23.5 kg) |
| Weight Capacity (rack) | 1100 lbs (499 kg) | — |
| Cord Length | 6 ft (1.8 m) | 6 ft (1.8 m) |
| Operating Temp | 32°–104°F (0°–40°C) | 32°–104°F (0°–40°C) |
| Enclosure Platform | BGR series | EIA 19-in rack (22–34 in depth) |
| Certifications | — | cTUVus, Energy Star 2.0, REACH |
| TAA Compliant | — | No |
| Network Management | Optional (UPX-RLNK-CARD) | Included (UPX-RLNK bundled) |
Frequently Asked Questions
Which should you choose: the FWD-CBS-1.5KVA-B27 or the OL1500R-2?
The OL1500R-2 is the stronger choice when power quality and remote management are the primary requirements in a standard 19-inch rack environment. Its Online double-conversion topology eliminates all transfer time (versus a finite transfer time on the line-interactive FWD-CBS-1.5KVA-B27), delivers complete input isolation, and carries Energy Star 2.0 and cTUVus certifications not listed for the FWD-CBS-1.5KVA-B27. It is also substantially smaller (1U / 16 in deep vs 2U / 27 in deep) and lighter (44.7 lbs vs ~132 lbs estimated), and the UPX-RLNK-OL1500R-2 SKU bundles network bank-outlet control for 8 outlets without an add-on card. Specify the FWD-CBS-1.5KVA-B27 when the installation is built around a Middle Atlantic BGR series enclosure and the 23-inch-wide, 2RU structural integration, 1100 lb weight capacity, and BGR platform compatibility are required — capabilities the OL1500R-2 does not provide.
Is the FWD-CBS-1.5KVA-B27 or OL1500R-2 better for protecting sensitive network and security equipment from power disturbances?
The OL1500R-2 is better suited for sensitive loads. Its Online double-conversion topology keeps the load running continuously from the inverter, providing zero transfer time and complete isolation from input voltage and frequency anomalies. The FWD-CBS-1.5KVA-B27 uses a Line Interactive topology with MOV surge protection, which corrects sags and swells but does involve a transfer event when switching to battery. Neither unit's battery runtime under load is specified in the provided data.
Can I mount the FWD-CBS-1.5KVA-B27 in a standard 19-inch equipment rack?
Not as a standard rack unit. The FWD-CBS-1.5KVA-B27 is 23 inches wide — wider than the standard EIA 19-inch rack opening — and is specified for Middle Atlantic BGR series enclosures. It ships with Middle Atlantic mounting hardware for that platform. The OL1500R-2 is 19 inches wide and fits any standard EIA 19-inch rack with a minimum usable depth of 22 inches.
Do both units include network management, or is it an add-on?
They differ. The OL1500R-2 is sold as the 'UPX-RLNK-OL1500R-2' SKU, which includes the UPX-RLNK network card with bank-level outlet control across 8 outlets out of the box. The FWD-CBS-1.5KVA-B27 lists network enablement as available only 'with UPX-RLNK-CARD,' meaning the card is a separate accessory, not included in the base unit. The specific outlet count for the FWD-CBS-1.5KVA-B27 is not enumerated in the provided specifications.
More UPS Comparisons
- Middle Atlantic FWD-CBS-1.5KVA-B27 vs ATEN OL1500LV
- Middle Atlantic FWD-CBS-1.5KVA-B27 vs CyberPower OL1500RTXL2U
- Middle Atlantic FWD-CBS-1.5KVA-B27 vs Middle Atlantic OL1500R-8
- Middle Atlantic OL1500R-2 vs ATEN OL1500LV
- Middle Atlantic OL1500R-2 vs CyberPower OL1500RTXL2U
- Middle Atlantic OL1500R-2 vs Panduit U02S11L
UPS Buying Guides
Get a Second Opinion on Your Camera Choice
Share your site layout, coverage goals, and budget. Our team will validate the camera selection, flag anything we would change, and recommend products that match the use case.