Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: UPX-RLNK-OL1500R-2
UPC: 656747397868
Condition: New
Write a Review 49% OFF

Middle Atlantic Nexsys 1.5KVA Online UPS Bank Ctrl - UPX-RLNK-OL1500R-2

Middle Atlantic UPX-RLNK-OL1500R-2 Nexsys 1500VA Online Double-Conversion Rack UPS with Bank Outlet ControlThe Middle Atlantic UPX-RLNK-OL1500R-2 is a…

$4,156.00 $2,128.99 SAVE $2027
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Middle Atlantic Nexsys 1.5KVA Online UPS Bank Ctrl - UPX-RLNK-OL1500R-2

$4,156.00
$2,128.99

Overview

SKU: UPX-RLNK-OL1500R-2
UPC: 656747397868
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Middle Atlantic UPX-RLNK-OL1500R-2 Nexsys 1500VA Online Double-Conversion Rack UPS with Bank Outlet Control

The Middle Atlantic UPX-RLNK-OL1500R-2 is a 1500VA / 1350W online double-conversion UPS engineered for AV racks, security head-end closets, and IT infrastructure rooms where zero transfer time and remote outlet management are non-negotiable. Unlike line-interactive or standby UPS units that switch to battery on a fault, online double-conversion continuously regenerates clean AC output from the inverter — utility power never reaches your equipment directly. For NVR stacks, managed switches, or access control servers where a momentary brownout can corrupt a database or drop a camera feed, this topology is the correct starting point.

Key Features

  • Online Double-Conversion Topology: The inverter drives the load 100% of the time, so there is no transfer gap when utility power fails or surges. Equipment connected to the UPX-RLNK-OL1500R-2 sees a regulated 110–127 VAC sine wave regardless of what the grid is doing — critical for NVRs and servers that trip on micro-interruptions.
  • 1500VA / 1350W Capacity: At a 0.9 power factor, 1350W of real load capacity gives you enough headroom for a mid-density security rack — a 16-channel NVR, a PoE switch, a managed firewall, and several storage drives without pushing the unit past 80% load, which is the safe operating ceiling for sustained runtime.
  • Bank-Controlled Outlet Management: All 8 NEMA 5-15R receptacles are grouped into switchable banks. With the included network card, you can remotely power-cycle individual outlet banks — restart a frozen NVR without touching the rack, sequence startup to avoid inrush stacking, or shed non-critical loads to extend battery runtime during an extended outage.
  • Network Card Included: The UPX-RLNK-OL1500R-2 ships with a network management card pre-installed. Remote monitoring, outlet control, and UPS status alerts are available over IP without an additional accessory purchase — a meaningful cost and installation difference versus UPS models that treat network management as an upsell.
  • Energy Star 2.0 Certified: Online double-conversion units typically run less efficiently than line-interactive designs, but the Energy Star 2.0 rating means this unit has cleared efficiency benchmarks that reduce heat output and operating cost in always-on deployments. In a 24/7 security operations environment, efficiency losses compound over thousands of hours.
  • 2U Rackmount Form Factor (19 in W × 3.5 in H × 16 in D): Fits standard 19-inch EIA racks with a 16-inch depth footprint, accommodating rack cabinets with a minimum usable depth of 22 inches and maximum of 34 inches. Four mounting points secure the chassis — relevant in mobile or vibration-prone environments. At 44.7 lbs, plan for two-person installation.
  • cTUVus Safety Listed: The cTUVus mark covers both US (UL) and Canadian (CSA) safety requirements under a single third-party listing. For commercial installations that require AHJ sign-off or insurance compliance, this covers both markets without sourcing a separate CSA-listed unit.
  • REACH / FCC Compliance: REACH compliance confirms the unit has been evaluated against EU chemical substance restrictions — relevant for integrators working on government, healthcare, or environmentally sensitive facilities with material compliance requirements.
  • NEMA 5-15P Input Plug with 6 ft Cord: The standard 15-amp NEMA 5-15P plug connects to any standard US outlet or PDU with a 5-15R receptacle. The 6-foot cord gives reasonable slack for most rack-to-PDU runs without excess cable management overhead.
  • Operating Temperature Range 32°–104°F (0°–40°C): Standard commercial operating range. Adequate for conditioned data rooms and equipment closets. Not suitable for unconditioned outdoor enclosures or industrial environments that regularly exceed 104°F — factor this in for warm-climate wiring closets without dedicated cooling.

Integration and Compatibility

The UPX-RLNK-OL1500R-2 is designed for integration into Middle Atlantic rack systems and is equally at home in any standard 19-inch EIA rack cabinet. The included network card enables SNMP-based monitoring, meaning it can report UPS status into most network management platforms and enterprise monitoring systems without additional middleware. For security integrators building NVR-based surveillance systems or structured rack deployments, bank outlet control allows logical grouping — for example, placing all camera-side PoE switches on one bank and recording servers on another, so a power-cycle command doesn't inadvertently restart both simultaneously.

The 8 NEMA 5-15R receptacles support standard IEC or NEMA loads up to 15 amps total input. If your rack load exceeds 1350W or includes high-draw servers requiring 20-amp or C13/C19 receptacles, evaluate a higher-capacity model in the Nexsys line. For rack power distribution planning, consider pairing this UPS with a separate PDU downstream to expand receptacle count while keeping the UPS as the conditioning and backup stage. Refer to a UPS selection guide to verify runtime estimates against your specific load profile before specifying this unit.

Frequently Asked Questions

Q: What is the difference between the online double-conversion topology in the UPX-RLNK-OL1500R-2 and a line-interactive UPS?

A: In an online double-conversion unit like the UPX-RLNK-OL1500R-2, the inverter is always active and always powering the load — utility power is continuously converted to DC and back to AC. There is zero transfer time on power loss. A line-interactive UPS passes utility power through directly and only switches to battery when voltage goes out of range, introducing a brief transfer gap (typically 2–8 ms) that can affect sensitive electronics.

Q: Does the UPX-RLNK-OL1500R-2 include a network management card or is it an optional add-on?

A: The network card is included in the box — it is not an optional accessory for this model. The unit ships network-enabled with remote outlet bank control and UPS monitoring accessible over IP.

Q: How many outlets does the UPX-RLNK-OL1500R-2 provide and what receptacle type are they?

A: The unit has 8 NEMA 5-15R receptacles organized into switchable banks for remote control. The input plug is NEMA 5-15P on a 6-foot cord drawing up to 15 amps.

Q: What rack depth is required to install the UPX-RLNK-OL1500R-2?

A: The unit requires a minimum rack mounting depth of 22 inches and supports up to 34 inches maximum mounting depth. The chassis itself is 16 inches deep and 3.5 inches tall (2U) in a standard 19-inch wide form factor with 4 mounting points.

Q: Is the UPX-RLNK-OL1500R-2 TAA compliant for government procurement?

A: No — the UPX-RLNK-OL1500R-2 is explicitly listed as not TAA compliant. If your project requires TAA compliance for federal or GSA purchasing, you will need to evaluate an alternate model.

Q: What safety and efficiency certifications does the UPX-RLNK-OL1500R-2 carry?

A: The unit holds a cTUVus listing (covering both US UL and Canadian CSA safety requirements) and is Energy Star 2.0 certified for efficiency. It also carries REACH compliance for chemical substance requirements.

Jerry Tildsen
Jerry Tildsen

The UPX-RLNK-OL1500R-2 is one of the few 1500VA rack UPS options that ships with an active network card and bank-level outlet control at this price tier — for security integrators building remotely managed head-end racks, that combination eliminates a common service-call scenario where a frozen NVR or stuck recorder requires a site visit just to power-cycle one device. The 1350W real power output at a 0.9 power factor is what actually matters for load planning, not the VA rating alone.

Technical Highlights:

  • Online Double-Conversion: Zero-transfer-time topology means your NVR, managed switch, or access control server never sees a gap between utility and battery — unlike line-interactive designs that take 2–8 ms to switch, which is enough to reboot some embedded systems.
  • Bank Outlet Control via Network Card: With 8 NEMA 5-15R outlets in switchable banks and the included network card, you can issue a remote power-cycle to a specific bank without touching the rack — sequence restarts, shed loads to extend runtime, or automate recovery scripts via SNMP.
  • Energy Star 2.0 on an Online Topology: Online double-conversion units are inherently less efficient than line-interactive designs because the inverter runs continuously. The Energy Star 2.0 rating means this unit has cleared efficiency thresholds that reduce both heat load in the rack and long-term operating cost — worth factoring for always-on 24/7 deployments.

Deployment Considerations:

  • At 44.7 lbs in a 2U chassis, plan for two-person installation — slide rails or a lift assist is advisable in tall racks. Verify your rack cabinet provides at least 22 inches of usable mounting depth before ordering.
  • The NEMA 5-15P input plug is rated for 15 amps total — with 1350W of UPS capacity, you are near the practical limit of a single 15A branch circuit at continuous load. Size your connected equipment accordingly and do not daisy-chain this UPS from a PDU that is already loaded near its circuit breaker threshold. Also note: TAA compliance is absent, which disqualifies this unit from federal procurement vehicles requiring TAA.

This unit is well-suited for mid-density commercial security racks in managed service or enterprise campus deployments where remote outlet control reduces truck rolls and online topology protects recording continuity during utility instability — a physical security operations center or multi-NVR closet serving a retail portfolio is a natural fit.

Specifications
Cord Length: 6 ft (1.8 m)
Depth: 16 in (40.6 cm)
Height: 3.5 in (8.9 cm)
Operating Temp: 32° - 104°F (0° - 40°C)
Weight: 44.7 lbs (20.3 kg)
Shipping Weight: 51.85 lbs (23.5 kg)
Width: 19 in (48.3 cm)
Mounting Points: 4
Plug Type: NEMA 5-15P
Receptacle Type: NEMA 5-15R
Taa Compliant: No
Upc: 656747397868
Rohs: Patents
Ac Voltage Output: 110-127 VAC
Amps: 15 Amp
Mounting Depth Max: 34 in (86.4 cm)
Mounting Depth Min: 22 in
Operating Temperature: 32° - 104°F (0° - 40°C)
Product Weight: 44.7 lbs (20.3 kg)
Va Rating: 1500VA
Watts: 1350 W
Outlet Control Type: Bank
Outlet Count: 8
Topology: Online
Csa: cTUVus
Department Of Energy: Energy Star 2.0
Fcc: REACH
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources