Middle Atlantic UPX-RLNK-OL1000R-2 1KVA Online Rack UPS with Bank ControlThe Middle Atlantic UPX-RLNK-OL1000R-2 is a 1000VA / 1000W double-conversion …

$3,667.00 $1,876.99 SAVE $1790
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Middle Atlantic Nexsys 1KVA Online UPS Bank Ctrl - UPX-RLNK-OL1000R-2

$3,667.00
$1,876.99

Overview

SKU: UPX-RLNK-OL1000R-2
UPC: 656747397844
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Middle Atlantic UPX-RLNK-OL1000R-2 1KVA Online Rack UPS with Bank Control

The Middle Atlantic UPX-RLNK-OL1000R-2 is a 1000VA / 1000W double-conversion online UPS designed for security rack systems where power conditioning and remote outlet management are operational requirements, not optional upgrades. Part of the Middle Atlantic Nexsys power line, it ships in a 2U rack form factor at 19 inches wide — a direct fit for standard EIA racks without adapter rails.

Overview

Online double-conversion topology means incoming AC is continuously converted to DC and back to clean AC — your connected equipment never runs on raw utility power, even under normal conditions. That eliminates sags, surges, and frequency variations before they reach your NVRs, switches, or access control panels. This is a meaningfully different protection class than line-interactive or standby UPS designs that only switch to battery during an outage.

Key Features

  • Online Double-Conversion Topology: Zero transfer time during power events — the output waveform never breaks because the inverter is always active. Critical for NVRs and servers that can corrupt recordings on even a 4ms power glitch.
  • 1000VA / 1000W Rating: The VA and watt ratings match (1.0 power factor), which means you can load it to the full 1000W without derating — straightforward capacity planning for dense security racks.
  • 8-Outlet Bank Control: Outlets are grouped into controllable banks, accessible via the included network card. You can remotely sequence, reboot, or shed specific load groups without touching the rack — useful for staged recovery after a facility-wide power event.
  • Network Card Included: SNMP/web-based remote management comes standard, not as an add-on. Monitor runtime, load percentage, battery health, and trigger outlet actions from your building management or NMS platform.
  • Energy Star 2.0 Certified: Online UPS units carry higher idle losses than standby designs; the Energy Star 2.0 compliance indicates this unit meets efficiency thresholds that reduce heat load and operating cost in always-on rack environments.
  • 110–127 VAC Output / NEMA 5-15R Receptacles: Eight NEMA 5-15R outlets on a 15A circuit. Confirm your total connected load stays under 15A (1800W at 120V) — the 1000W inverter is the binding constraint, not the receptacles.
  • Mounts in Racks 22–34 Inches Deep: The 16-inch unit depth fits racks from 22 to 34 inches deep with four mounting points, covering most mid-depth and full-depth security enclosures in the Middle Atlantic rack lineup.
  • cTUVus Safety Listed: North American safety listing for rack-mount power equipment — required for many commercial installation sign-offs and insurance compliance.

Integration and Compatibility

The UPX-RLNK-OL1000R-2 (often searched as UPX RLNK OL1000R 2) integrates with SNMP-capable NMS and BMS platforms via the built-in network card. The NEMA 5-15P input plug connects to standard 15A commercial circuits. Pair with a managed PoE switch on a dedicated outlet bank so camera infrastructure can be power-cycled independently from recording equipment. Operating temperature range of 32°–104°F (0°–40°C) is appropriate for conditioned equipment rooms and wiring closets — not outdoor or unconditioned spaces.

Frequently Asked Questions

Q: What is the difference between the online topology in the UPX-RLNK-OL1000R-2 and a line-interactive UPS?

A: Online double-conversion continuously regenerates the output from the inverter regardless of input quality — there is no transfer time to battery. Line-interactive units switch to battery only when input goes out of tolerance, introducing a brief gap. For NVRs and network switches, the online topology is the safer choice.

Q: Does the UPX-RLNK-OL1000R-2 include a network management card?

A: Yes, a network card is included and network-enabled out of the box, supporting remote outlet bank control and UPS monitoring without an additional accessory purchase.

Q: How many outlets does the UPX-RLNK-OL1000R-2 provide, and are they individually switched?

A: It provides 8 NEMA 5-15R outlets organized into controllable banks. Control is at the bank level, not per individual outlet.

Q: What rack depth is required to install the UPX-RLNK-OL1000R-2?

A: Mounting depth minimum is 22 inches and maximum is 34 inches. The unit itself is 16 inches deep with four rack-mount points on a standard 19-inch width.

Q: Is the UPX-RLNK-OL1000R-2 TAA compliant?

A: No, this model is not TAA compliant per the manufacturer specification. If your project requires TAA compliance for federal procurement, verify an alternate model before specifying.

Karl Wilson
Karl Wilson

The spec that matters most on the UPX-RLNK-OL1000R-2 is the 1.0 power factor — at 1000VA, you get the full 1000W of usable output with no derating penalty. Most commercial UPS units in this VA class carry a 0.8 or 0.9 power factor, which means a nominal 1000VA unit only delivers 800–900W. Here that gap is closed, which matters when you're stacking NVRs, managed switches, and access control hardware in a single rack and counting watts carefully.

Technical Highlights:

  • Online Double-Conversion: Zero-transfer-time protection — inverter is always live, so your NVRs never experience even a millisecond brownout during a utility event. This is the correct topology for video recording infrastructure.
  • Bank-Level Outlet Control via Network Card: Eight NEMA 5-15R outlets in controllable banks with an included network card lets you sequence reboots and shed non-critical loads remotely — no truck roll to cycle a locked rack after a power event.
  • Energy Star 2.0: Online UPS designs run hotter and less efficiently than standby types by nature; the Energy Star 2.0 rating confirms this unit meets efficiency minimums that keep heat load manageable in closed rack enclosures.

Deployment Considerations:

  • The NEMA 5-15P input pulls up to 15A — at full 1000W load you're at the circuit breaker limit. Leave 20% headroom and plan for a dedicated 20A circuit with a 5-15P-to-5-20R adapter if your panel supports it.
  • This unit is not TAA compliant, which disqualifies it from federal government and some state/local procurement contracts. Confirm compliance requirements before quoting on government projects.

The UPX-RLNK-OL1000R-2 is the right call for commercial security integrators building out 1U/2U NVR-plus-switch racks in wiring closets where remote power management matters and the installation team won't be on-site for routine reboot cycles.

Specifications
Cord Length: 6 ft (1.8 m)
Depth: 16 in (40.6 cm)
Height: 3.5 in (8.9 cm)
Operating Temp: 32° - 104°F (0° - 40°C)
Weight: 33.1 lbs (15 kg)
Shipping Weight: 38.6 lbs (17.5 kg)
Width: 19 in (48.3 cm)
Mounting Points: 4
Plug Type: NEMA 5-15P
Receptacle Type: NEMA 5-15R
Taa Compliant: No
Upc: 656747397844
Rohs: Patents
Ac Voltage Output: 110-127 VAC
Amps: 15 Amp
Mounting Depth Max: 34 in (86.4 cm)
Mounting Depth Min: 22 in
Operating Temperature: 32° - 104°F (0° - 40°C)
Product Weight: 33.1 lbs (15 kg)
Va Rating: 1000VA
Watts: 1000 W
Outlet Control Type: Bank
Outlet Count: 8
Topology: Online
Csa: cTUVus
Department Of Energy: Energy Star 2.0
Fcc: REACH
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources