Rack Power Supplies
Showing Results for Rack Power Supplies
-
Panduit
SKU: D5CMW
Panduit D5CMW 45RU PDU Cable Management Bracket - White
$330.76 $241.99 Save $88.77 -
Panduit
SKU: E36G32L
Panduit EL2P MI PDU 20/16 AMP IEC 60309 3P+N+E 6
$3,588.48 $3,253.99 Save $334.49 -
Panduit
SKU: E48E22L
Panduit EL2P MI PDU 30 AMP NEMA L15-30P-3MBLK PK
$3,187.38 $2,889.99 Save $297.39 -
Panduit
SKU: E48G04L
Panduit EL2P MI PDU 30 AMP NEMA L21-30P-3MBLK PK
$4,545.24 $4,121.99 Save $423.25 -
Panduit
SKU: E48E21L
Panduit EL2P MI PDU 30 AMP NEMA L21-30P-3MBLK PK
$2,889.18 $2,619.99 Save $269.19 -
Panduit
SKU: E48D23L
Panduit EL2P MI PDU 30 AMP NEMA L22-30P-3MBLK PK
$2,436.41 $2,209.99 Save $226.42 -
Panduit
SKU: E36G18L
Panduit EL2P MI PDU 30 AMP NEMA L6-30P-3MBLK PK1
$3,508.68 $2,865.99 Save $642.69 -
Panduit
SKU: E48E20L
Panduit EL2P MI PDU 32/30 AMP IEC 60309 3P+N+E 6
$3,024.84 $2,742.99 Save $281.85 -
-
Panduit
SKU: E42D22L
Panduit EL2P MI PDU 60 AMP IEC 60309 3P+E 9H 60A
$2,920.68 $2,385.99 Save $534.69 -
Panduit
SKU: E48E25L
Panduit EL2P MI PDU 63/60 AMP IEC 60309 3P+N+E 6
$3,600.65 $3,264.99 Save $335.66 -
Panduit
SKU: E48G33L
Panduit EL2P MS PDU 20/16 AMP IEC 60309 3P+N+E 6
$4,362.95 $3,955.99 Save $406.96 -
Panduit
SKU: E48G32L
Panduit EL2P MS PDU 30 AMP NEMA L15-30P-3MBLK PK
$4,759.44 $4,315.99 Save $443.45 -
Panduit
SKU: E48G31L
Panduit EL2P MS PDU 30 AMP NEMA L21-30P-3MBLK PK
$4,463.75 $4,047.99 Save $415.76 -
Panduit
SKU: E48G30L
Panduit EL2P MS PDU 32/30 AMP IEC 60309 3P+N+E 6
$4,570.01 $4,143.99 Save $426.02 -
Rack Power Supplies
Rack-mount power supplies deliver regulated DC to access control panels, CCTV head-ends, and intrusion systems from a 19-inch rack or cabinet. They provide battery backup, output supervision, and centralized distribution for multi-door or multi-camera installations.
Plan Your Deployment
- Output voltage (12/24 VDC) and total amperage at continuous load
- Rack units (1U, 2U, 3U) and depth for the cabinet
- Battery backup sizing (amp-hours) for target hold-up time
- Output count and individually fused/supervised channels
- Fire alarm interface for controlled lock release on alarm
What to Look For
Size the supply for 125% of the calculated continuous load and confirm the battery bank meets the hold-up time required by local code (commonly 4 or 24 hours). Supervised outputs report shorted or open circuits back to the panel, which is required for UL 1076 and UL 294 installations. Rack integration keeps service access at the central gear location.
Common Deployment Scenarios
Rack power supplies are standard in enterprise IDF closets, data center security rooms, and multi-door openings where copper home-runs converge on a central location. They replace scattered wall-wart or transformer-based power in larger systems.