APC by Schneider Electric 3 Pole 20A PDU - PDM3520L2120-740
3-pole, 5-wire, 20A IT Power Distribution Module (PDM) designed for critical infrastructure within data centers and enterprise IT environments
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The PDM3520L2120-440 is APC by Schneider Electric's 3-pole, 5-wire IT Power Distribution Module designed for data center and server room environments where 208V three-phase power needs to be stepped down and distributed cleanly at 120V to rack-level equipment. This unit bridges high-density facility power — delivered at 208V, 60Hz — down to a 120V, 20A NEMA L21-20 output, with both metered and monitored PDU functionality and a 4.4-meter cord that gives you genuine cable management flexibility between the panel and the rack. If you're building out or expanding a data center power chain and need a purpose-built module that handles the 208-to-120V conversion with Web/SNMP visibility, the PDM3520L2120-440 (often searched as PDM3520L2120 440) is worth examining closely.
The PDM3520L2120-440 is designed to integrate into APC's broader APC by Schneider Electric power infrastructure ecosystem, sitting between facility-level 208V distribution and rack-level 120V consumption. It works alongside rack-mount PDUs and power distribution in multi-tier power architectures. The SNMP management interface will integrate with most enterprise NMS platforms that support standard MIBs — APC publishes its PowerNet MIB for SNMP polling, which is widely supported. For environments running EcoStruxure IT or APC's Data Center Expert, this unit can feed into those dashboards directly. If you're pairing this module with downstream UPS systems or planning a complete power chain, verify your branch circuit breaker rating matches the 20A draw rating of this unit. The L21-20 output is a three-phase connector — confirm your downstream rack PDU or equipment accepts L21-20 input before purchasing. This is not a standard NEMA 5-15/5-20 outlet; it will not connect to standard single-phase North American plugs without an adapter.
Q: What is the input voltage for the PDM3520L2120-440?
A: The PDM3520L2120-440 accepts a nominal input voltage of 208V AC at 60Hz. This is standard three-phase facility power found in commercial data centers and larger IT rooms.
Q: What type of output connector does the PDM3520L2120-440 use?
A: The output connection is a NEMA L21-20 twist-lock receptacle, rated for 20A at 120V. This is a three-phase connector and is not compatible with standard single-phase NEMA 5-15 or 5-20 plugs without an appropriate adapter.
Q: Does the PDM3520L2120-440 support remote monitoring?
A: Yes. The PDM3520L2120-440 supports Web-based management and SNMP, allowing integration with network management systems for remote monitoring of power draw, status alerts, and threshold management.
Q: How long is the power cord on the PDM3520L2120-440?
A: The unit ships with a 4.4-meter (approximately 14.4-foot) cord, which is typically sufficient to run from a ceiling bus bar or wall panel to a mid-row rack without extenders.
Q: Is the PDM3520L2120-440 UL listed?
A: Yes, the PDM3520L2120-440 carries UL certification and is also RoHS compliant, meeting safety and environmental standards required by most commercial enterprise data center facilities.
Q: What are the physical dimensions and weight of the PDM3520L2120-440?
A: The unit measures 445mm wide × 406mm deep × 127mm tall and weighs 4.45kg. Packaged weight is 5kg.

The PDM3520L2120-440 fills a specific and often overlooked gap in data center power architecture: the 208V-to-120V step-down at the distribution module level, before power hits the rack PDU. With a 20A maximum per-phase draw through the L21-20 output and a 4.4-meter cord, this unit is engineered for installations where facility power arrives at 208V but your rack equipment — particularly 1U security appliances, network switches, and compute nodes — expects 120V. That's a common mismatch in retrofitted enterprise facilities and co-lo suites, and the PDM3520L2120-440 handles it without adding a transformer to the BOM.
Technical Highlights:
Deployment Considerations:
This module is well-suited for mid-size enterprise data centers and co-location deployments where 208V three-phase service is already present at the facility level but row-level or rack-level equipment requires 120V at controlled, monitored amperage — particularly in security operations centers or network infrastructure rooms where power visibility directly supports uptime SLAs.