Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric PDM3520L2120-440 3-Pole 5-Wire IT Power Distribution Module

Overview

The PDM3520L2120-440 is APC by Schneider Electric's 3-pole, 5-wire IT Power Distribution Module designed for data center and server room environments where 208V three-phase power needs to be stepped down and distributed cleanly at 120V to rack-level equipment. This unit bridges high-density facility power — delivered at 208V, 60Hz — down to a 120V, 20A NEMA L21-20 output, with both metered and monitored PDU functionality and a 4.4-meter cord that gives you genuine cable management flexibility between the panel and the rack. If you're building out or expanding a data center power chain and need a purpose-built module that handles the 208-to-120V conversion with Web/SNMP visibility, the PDM3520L2120-440 (often searched as PDM3520L2120 440) is worth examining closely.

Key Features

  • 208V Input / 120V Output Conversion: Accepts 208V three-phase facility power and delivers 120V at the output — critical in mixed-voltage data centers where UPS infrastructure operates at 208V but individual 1U servers and appliances expect 120V. Eliminates the need for separate step-down transformers at each rack.
  • 20A Maximum Per-Phase Current Draw: Rated at 20A per phase via the NEMA L21-20 output connection, which keeps the unit within standard branch-circuit limits while providing enough headroom for high-draw 1U/2U servers. Know your equipment load before deployment — this isn't a high-density 30A or 60A feed.
  • NEMA L21-20 Output Connection: The L21-20 twist-lock connector is the standard for 20A three-phase power in commercial rack environments. Ensures a secure, vibration-resistant connection that won't loosen during server maintenance cycles or equipment moves.
  • Metered and Monitored PDU Functionality: Both metering and monitoring are active — metered PDUs show you real-time current draw so you can prevent overloads; monitored adds remote visibility via the management interface. Together they give you the power data you need without a separate energy metering layer.
  • Web/SNMP Management Platform: Network-accessible management over Web and SNMP means you can integrate this unit into your existing NMS (Nagios, SolarWinds, PRTG, etc.) without proprietary middleware. Pull current readings, set thresholds, and receive alerts remotely — useful when the data center is unstaffed.
  • LED Indicators: On-unit LED status indicators provide at-a-glance confirmation of power state without requiring a laptop or management console — a small but practical feature during physical rack audits or emergency troubleshooting.
  • 4.4-Meter Cord Length: The 4.4m (roughly 14.4 feet) cord gives you enough reach to run from a ceiling-mounted bus bar or wall panel to a rack mid-row without cord extenders or excessive slack. Measure your panel-to-rack distance before ordering — if you're closer than 2 meters, you'll have excess to manage.
  • RoHS and UL Certified: RoHS compliance keeps this unit usable in environments with hazardous materials restrictions. UL listing means it's passed independent safety testing — a minimum requirement for most commercial data center and enterprise IT facilities.
  • Compact 445 × 406 × 127mm Footprint: At 127mm tall (approximately 3U equivalent footprint if rack-mounted), this module fits cleanly into standard rack environments. Weight of 4.45 kg means a single technician can handle installation without a lift.

Integration and Compatibility

The PDM3520L2120-440 is designed to integrate into APC's broader APC by Schneider Electric power infrastructure ecosystem, sitting between facility-level 208V distribution and rack-level 120V consumption. It works alongside rack-mount PDUs and power distribution in multi-tier power architectures. The SNMP management interface will integrate with most enterprise NMS platforms that support standard MIBs — APC publishes its PowerNet MIB for SNMP polling, which is widely supported. For environments running EcoStruxure IT or APC's Data Center Expert, this unit can feed into those dashboards directly. If you're pairing this module with downstream UPS systems or planning a complete power chain, verify your branch circuit breaker rating matches the 20A draw rating of this unit. The L21-20 output is a three-phase connector — confirm your downstream rack PDU or equipment accepts L21-20 input before purchasing. This is not a standard NEMA 5-15/5-20 outlet; it will not connect to standard single-phase North American plugs without an adapter.

Frequently Asked Questions

Q: What is the input voltage for the PDM3520L2120-440?

A: The PDM3520L2120-440 accepts a nominal input voltage of 208V AC at 60Hz. This is standard three-phase facility power found in commercial data centers and larger IT rooms.

Q: What type of output connector does the PDM3520L2120-440 use?

A: The output connection is a NEMA L21-20 twist-lock receptacle, rated for 20A at 120V. This is a three-phase connector and is not compatible with standard single-phase NEMA 5-15 or 5-20 plugs without an appropriate adapter.

Q: Does the PDM3520L2120-440 support remote monitoring?

A: Yes. The PDM3520L2120-440 supports Web-based management and SNMP, allowing integration with network management systems for remote monitoring of power draw, status alerts, and threshold management.

Q: How long is the power cord on the PDM3520L2120-440?

A: The unit ships with a 4.4-meter (approximately 14.4-foot) cord, which is typically sufficient to run from a ceiling bus bar or wall panel to a mid-row rack without extenders.

Q: Is the PDM3520L2120-440 UL listed?

A: Yes, the PDM3520L2120-440 carries UL certification and is also RoHS compliant, meeting safety and environmental standards required by most commercial enterprise data center facilities.

Q: What are the physical dimensions and weight of the PDM3520L2120-440?

A: The unit measures 445mm wide × 406mm deep × 127mm tall and weighs 4.45kg. Packaged weight is 5kg.

James Everett
James Everett

The PDM3520L2120-440 fills a specific and often overlooked gap in data center power architecture: the 208V-to-120V step-down at the distribution module level, before power hits the rack PDU. With a 20A maximum per-phase draw through the L21-20 output and a 4.4-meter cord, this unit is engineered for installations where facility power arrives at 208V but your rack equipment — particularly 1U security appliances, network switches, and compute nodes — expects 120V. That's a common mismatch in retrofitted enterprise facilities and co-lo suites, and the PDM3520L2120-440 handles it without adding a transformer to the BOM.

Technical Highlights:

  • 208V → 120V at 20A: The 20A per-phase current cap means your downstream load needs to stay well under 2.4kW to avoid tripping protection — calculate actual draw before committing to this module over a higher-amperage variant.
  • Web/SNMP Management: SNMP integration lets this unit report into existing NMS platforms using APC's PowerNet MIB — no proprietary controller or additional hardware required for basic threshold alerting and current monitoring.
  • Dual PDU Classification (Metered + Monitored): Most environments deploy either metered or monitored — getting both in a single unit means you have real-time current display at the unit AND remote SNMP polling simultaneously, which is useful during initial load balancing after install.

Deployment Considerations:

  • The NEMA L21-20 output is a three-phase twist-lock — verify your downstream rack PDU or equipment has a matching L21-20 input. Mismatched connectors are the most common install error with this class of module.
  • At 4.45kg and 445mm wide, this unit is not rack-mounted in the traditional 1U sense — confirm your physical mounting arrangement (overhead ladder rack, side panel, floor mount) before the unit arrives on site.

This module is well-suited for mid-size enterprise data centers and co-location deployments where 208V three-phase service is already present at the facility level but row-level or rack-level equipment requires 120V at controlled, monitored amperage — particularly in security operations centers or network infrastructure rooms where power visibility directly supports uptime SLAs.

Specifications
Pdu Types: Metered, Monitored
Product Colour: Black
Ac Outlets Quantity: 1 AC outlet(s)
Output Connections: NEMA L21-20
Cable Length: 4.4 m
Management Platform: Web/SNMP
Nominal Input Voltage: 208 V
Ac Input Frequency: 60 Hz
Nominal Output Voltage: 120 V
Maximum Total Current Draw Per Phase: 20 A
Compliance Certificates: RoHS
Certification: UL
Width: 445 mm
Depth: 406 mm
Height: 127 mm
Weight: 4.45 kg
Package Weight: 5 kg
Package Width: 445 mm
Package Depth: 406 mm
Package Height: 127 mm
Q&A
Reviews

APC IT Power Distribution Module - PDM3520L2120-440

$1,190.00
$779.99

RELATED PRODUCTS

Save $460.01
Image coming soon
Add to Cart The item has been added

APC by Schneider Electric PDM3520L2120-740

APC by Schneider Electric 3 Pole 20A PDU - PDM3520L2120-740

3-pole, 5-wire, 20A IT Power Distribution Module (PDM) designed for critical infrastructure within data centers and enterprise IT environments

    Usually Ships in 2-3 Weeks Free shipping over $499
    $1,320.00 $859.99 Save $460.01
    The item has been added Add to quote
    $1,320.00 $859.99 Save $460.01
    Save $460.01 Add to cart Add to quote

    System Design, Deployment & Technical Support

    Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

    Fixed scope • Fixed price

    System Design Assistance

    • Get help validating product compatibility
    • Coverage requirements
    • Storage planning and deployment architecture before you buy.
    Request Design Help

    Deployment & Configuration Support

    • Access fixed-scope support for rollout planning
    • User setup guidance
    • Migration and system standardization across single-site or multi-site deployments
    View Support Services

    Guides, Tools & Calculators

    • PoE requirements
    • Storage retention
    • Camera selection and deployment methodology
    Open Technical Resources