APC IT Power Distribution Module 2 - PDM2330L6-23-380
N IT Power Distribution Module designed to provide reliable power to rack-mounted equipment within data center or network closet environments
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The PDM2330L6-23-500 is a 208V AC IT power distribution module from APC by Schneider Electric designed to deliver structured power distribution within data center and IT rack environments. It accepts a 208V AC input and routes power through a single NEMA L6-30R receptacle — a twist-lock connector rated for 30A circuits — making it a purpose-built component for high-density rack builds where circuit-level power segregation matters. At 9.46 lb, this is a solid, commercially built unit sourced factory-new with no grey-market sourcing.
For data center architects and power distribution planners integrating APC infrastructure into existing 208V branch circuits, the PDM2330L6-23-500 (often searched as PDM2330L6 23 500) fills a specific role: providing a terminated, standards-compliant distribution point that keeps your downstream IT load on a known, documented circuit path rather than relying on field-assembled solutions.
The PDM2330L6-23-500 is engineered to integrate with APC's broader IT power infrastructure ecosystem. The 208V AC specification aligns with standard North American three-phase 208/120V distribution systems common in data centers, colocation facilities, and enterprise server rooms. The NEMA L6-30R receptacle is a standard twist-lock format supported by a wide range of power cords and PDU whips, giving you flexibility when connecting downstream rack PDUs or high-draw computing loads.
This module is UL listed, satisfying the electrical safety certification requirements that most enterprise and colocation environments mandate for all rack-mounted power components. For teams working within a broader UPS and power conditioning architecture — particularly APC Symmetra or Galaxy-series infrastructure — this distribution module provides a compliant, documented power path between the upstream distribution board and the rack-level load.
Verify your upstream circuit breaker and cabling are rated for the L6-30 standard (30A, 250V twist-lock) before installing. The 208V input requirement means this unit is not compatible with standard 120V branch circuits — confirm your panel voltage before ordering.
Q: What receptacle type does the PDM2330L6-23-500 provide?
A: The PDM2330L6-23-500 provides one NEMA L6-30R twist-lock receptacle rated for 208V AC service. This is a 30A locking outlet, not a standard straight-blade connection.
Q: What is the input voltage for the PDM2330L6-23-500?
A: The input voltage is 208V AC, matching the output. This unit is not compatible with standard 120V branch circuits — it requires a 208V source from a data center or enterprise distribution panel.
Q: Is the PDM2330L6-23-500 UL listed?
A: Yes. The PDM2330L6-23-500 carries UL certification, meeting the independent electrical safety evaluation required for commercial and enterprise data center installations.
Q: What environmental compliance certifications does the PDM2330L6-23-500 hold?
A: The unit is compliant with both RoHS (Restriction of Hazardous Substances) and REACH (Registration, Evaluation, Authorization and Restriction of Chemicals), supporting EU deployment and corporate ESG procurement requirements.
Q: How much does the PDM2330L6-23-500 weigh?
A: The unit weighs approximately 9.46 lb, light enough to install in standard EIA-310 equipment racks without additional structural reinforcement.
Q: What is the warranty on the PDM2330L6-23-500?
A: APC provides a 1-year limited manufacturer warranty on the PDM2330L6-23-500.

The PDM2330L6-23-500 is one of those components that doesn't get glamorized but causes real pain when it's wrong. The NEMA L6-30R twist-lock output is the detail that matters most here — you're not plugging a standard computer power cord into this. It's a 30A, 208V locking receptacle, which means your downstream equipment and power whip both need to be L6-30 compatible. Spec it correctly upfront and this module disappears into the rack and does its job; spec it wrong and you're ordering cord adapters on a deadline.
Technical Highlights:
Deployment Considerations:
This module fits cleanly into a planned APC power distribution hierarchy in a colocation or enterprise data center row where 208V single-phase circuits feed individual rack columns — particularly useful when a high-draw compute load or storage array needs a dedicated, documented 30A circuit with a standards-compliant locking termination point.