Rack Power Supplies
Showing Results for Rack Power Supplies
-
Vertiv
SKU: VP4NA0A3
Vertiv Rpdu Monitored Unit Level 80A 277/480V WYE 66.4KW Vertical (30) Anderson 2 - VP4NA0A3
In stock · Ships same business day$4,060.00 $2,784.99 Save $1,275.01 -
Vertiv
SKU: VP4UU0A1
Vertiv Rpdu Monitored Unit Level EC 11.0KW Variable Power Configuration Vertical ( - VP4UU0A1
In stock · Ships same business day$2,281.00 $1,564.99 Save $716.01 -
Vertiv
SKU: VP4N20A1
Vertiv Rpdu Monitored Unit Level EC 20A 120/208V WYE 5.7KW Vertical (33) Locking - VP4N20A1
In stock · Ships same business day$1,543.00 $1,058.99 Save $484.01 -
Vertiv
SKU: VP4N20A2
Vertiv Rpdu Monitored Unit Level EC 20A 120/208V WYE 5.7KW Vertical (36) Locking - VP4N20A2
In stock · Ships same business day$1,581.00 $1,084.99 Save $496.01 -
Vertiv
SKU: VP4N20A0
Vertiv Rpdu Monitored Unit Level EC 20A 120V 1.9KW Vertical (24) NEMA 5-20R 10FT - VP4N20A0
In stock · Ships same business day$1,140.00 $781.99 Save $358.01 -
Vertiv
SKU: VP4N20A7
Vertiv Rpdu Monitored Unit Level EC 20A 120V 1.9KW Vertical (24) NEMA 5-20R 10FT - VP4N20A7
In stock · Ships same business day$1,233.00 $845.99 Save $387.01 -
Vertiv
SKU: VP4N21A2
Vertiv Rpdu Monitored Unit Level EC 20A 208V 3.3KW Horizontal (10) Locking IEC C1 - VP4N21A2
In stock · Ships same business day$1,024.00 $702.99 Save $321.01 -
Vertiv
SKU: VP4N20A5
Vertiv Rpdu Monitored Unit Level EC 20A 208V 3.3KW Vertical (20) Locking IEC C13 - VP4N20A5
In stock · Ships same business day$1,403.00 $962.99 Save $440.01 -
Vertiv
SKU: VP4UV2A1
Vertiv Rpdu Monitored Unit Level EC 22.0KW Variable Power Configuration Horizontal - VP4UV2A1
In stock · Ships same business day$2,334.00 $1,600.99 Save $733.01 -
Vertiv
SKU: VP4UV0A2
Vertiv Rpdu Monitored Unit Level EC 22.0KW Variable Power Configuration Vertical ( - VP4UV0A2
In stock · Ships same business day$2,399.00 $1,627.99 Save $771.01 -
Vertiv
SKU: VP4UV0A3
Vertiv Rpdu Monitored Unit Level EC 22.0KW Variable Power Configuration Vertical ( - VP4UV0A3
In stock · Ships same business day$2,658.00 $1,822.99 Save $835.01 -
Vertiv
SKU: VP4N30AH
Vertiv Rpdu Monitored Unit Level EC 30A 120/208V 5.7KW Vertical (20) IEC C13 (4) - VP4N30AH
In stock · Ships same business day$1,618.00 $1,109.99 Save $508.01 -
Vertiv
SKU: VP4N30A7
Vertiv Rpdu Monitored Unit Level EC 30A 120/208V WYE 8.6KW Vertical (24) IEC C13 - VP4N30A7
In stock · Ships same business day$1,704.00 $1,168.99 Save $535.01 -
Vertiv
SKU: VP4N30A6
Vertiv Rpdu Monitored Unit Level EC 30A 120/208V WYE 8.6KW Vertical (36) IEC C13 - VP4N30A6
In stock · Ships same business day$1,606.00 $1,101.99 Save $504.01 -
Vertiv
SKU: VP4N30AR
Vertiv Rpdu Monitored Unit Level EC 30A 120/208V WYE 8.6KW Vertical (36) IEC C13 - VP4N30AR
In stock · Ships same business day$2,122.00 $1,455.99 Save $666.01 -
Vertiv
SKU: VP4N31A1
Vertiv Rpdu Monitored Unit Level EC 30A 208V 4.9KW Horizontal (10) Locking IEC C1 - VP4N31A1
In stock · Ships same business day$1,231.00 $844.99 Save $386.01
Rack Power Supplies
Rack-mount power supplies deliver regulated DC to access control panels, CCTV head-ends, and intrusion systems from a 19-inch rack or cabinet. They provide battery backup, output supervision, and centralized distribution for multi-door or multi-camera installations.
Plan Your Deployment
- Output voltage (12/24 VDC) and total amperage at continuous load
- Rack units (1U, 2U, 3U) and depth for the cabinet
- Battery backup sizing (amp-hours) for target hold-up time
- Output count and individually fused/supervised channels
- Fire alarm interface for controlled lock release on alarm
What to Look For
Size the supply for 125% of the calculated continuous load and confirm the battery bank meets the hold-up time required by local code (commonly 4 or 24 hours). Supervised outputs report shorted or open circuits back to the panel, which is required for UL 1076 and UL 294 installations. Rack integration keeps service access at the central gear location.
Common Deployment Scenarios
Rack power supplies are standard in enterprise IDF closets, data center security rooms, and multi-door openings where copper home-runs converge on a central location. They replace scattered wall-wart or transformer-based power in larger systems.