Vertiv
SKU: VP4N30A6
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The VP4N30AR is a unit-level monitored rack PDU from Vertiv's Geist line, rated at 30A / 8.6 kW on a 120/208V WYE input. Designed for 0U vertical mounting, it fits flush against the side rail of a standard rack without consuming rack unit space — the right choice when every U counts in a dense compute or network cabinet. Input power monitoring at ±1% accuracy gives you real consumption data at the unit level, not estimated draw, which matters when you're managing capacity across a multi-rack deployment. The NEMA L21-30P input plug matches the three-phase WYE feeds common in raised-floor data centers and server rooms built to ASHRAE A2/A3 thermal envelopes — the 60°C high-temperature grade rating accommodates hot-aisle containment installations where ambient temperatures run high.
The VP4N30AR is compatible with any rack infrastructure accepting a 0U vertical PDU and a NEMA L21-30P 30A circuit. Outlet mix — 36 IEC C13, 6 IEC C19, and 2 NEMA 5-20R — covers standard 1U/2U servers (C13), high-draw compute nodes and UPS bypass connections (C19), and legacy North American equipment (5-20R). Color-coded U-Lock receptacles prevent accidental disconnection on C13 and C19 ports. Dual Ethernet ports support daisy-chain deployment across multiple PDUs under a single IP address via IP aggregation, reducing switch port consumption in environments running monitored rack PDUs across dozens of cabinets. The hot-swappable monitoring module means the monitoring device can be replaced without dropping outlet power — useful in 24/7 environments where scheduled downtime for PDU maintenance is impractical. Environmental sensor port supports external temperature and humidity probes for in-cabinet ambient monitoring. TAA compliance qualifies the VP4N30AR for US federal procurement. Review the full Vertiv power distribution catalog for matching in-row and overhead PDU options. For UPS pairing and upstream power protection, see uninterruptible power supplies.
Input circuit must supply 30A on a NEMA L21-30P receptacle at 120/208V WYE — confirm panel capacity before deployment; at 8.6 kW continuous, derate the circuit to 24A usable per NEC 80% rule on a dedicated 30A breaker. Vertical 0U orientation requires side-mount brackets (verify rack compatibility before ordering). Dual Ethernet ports operate as a pass-through daisy chain; only one IP address is assigned per physical PDU — plan IP addressing accordingly when aggregating multiple units. Operating temperature ceiling of 60°C applies to the PDU itself; ensure the monitoring module's sensor port probe is positioned to measure representative in-cabinet ambient, not exhaust air directly from a server.