Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VP4N31A1 is a unit-level monitored, single-phase horizontal rack PDU rated at 30A and 208V (4.9kW), purpose-built for data center and server room deployments where you need outlet-level power visibility without paying for full switching capability. The 0U horizontal form factor fits flush in standard rack mount positions, keeping vertical rack space available for revenue-generating equipment. With ten locking IEC C13/C19 outlets on a NEMA L6-30P input cord (3 meters), this PDU targets dense 1U/2U server rows and network equipment enclosures running on 200–240V single-phase circuits — the bread-and-butter power configuration in co-location and enterprise machine rooms.
If you're managing a rack power distribution refresh or building out new compute rows, the VP4N31A1 delivers the monitoring visibility your facilities and IT teams need to track load balance, prevent circuit overloads, and feed DCIM or BMS platforms — all via standard protocols your existing infrastructure already speaks.
The VP4N31A1 integrates with Vertiv's broader power management ecosystem and connects to third-party DCIM platforms via SNMP v1/v2c/v3 and Modbus TCP. The supported protocol list — including NTP for time synchronization, Syslog for event forwarding, and SMTP for email alerting — maps directly to the integration requirements of platforms like Nlyte, Sunbird, or Schneider EcoStruxure IT. The 1x USB and 1x serial port (RS-232) provide console and firmware update access. For deployments standardizing on monitored rack PDUs across multiple cabinets, the consistent protocol support makes fleet-wide monitoring configuration repeatable.
If you're evaluating power infrastructure alongside network switches or compute gear for a new rack build, factor in the 30A circuit requirement — this PDU is not compatible with standard 20A branch circuits and requires a dedicated L6-30R receptacle or PDU tap box on your panel.
Q: What is the input plug type on the VP4N31A1?
A: The VP4N31A1 uses a NEMA L6-30P twist-lock plug on a 3-meter input cord, rated for 30A at 200–240V single-phase. It requires a dedicated L6-30R receptacle or compatible power source — not compatible with standard 5-15R or L5-30R outlets.
Q: Does the VP4N31A1 support SNMP v3?
A: Yes. The VP4N31A1 supports SNMP v1, v2c, and v3. SNMP v3 includes authentication and encryption options, meeting most enterprise and co-location security hardening requirements for network-connected power equipment.
Q: What type of outlets does the VP4N31A1 have, and are they locking?
A: The VP4N31A1 has 10 IEC outlets in a C13/C19 mix, all with locking connectors to prevent accidental disconnection. The C13 outlets accommodate standard server power cords; the C19 outlets handle higher-draw devices such as storage arrays and GPU nodes.
Q: Can the VP4N31A1 integrate with RADIUS or LDAP for centralized authentication?
A: Yes. The VP4N31A1 supports RADIUS, LDAP, and TACACS+ for centralized authentication and access control, allowing you to manage PDU credentials through your existing AAA infrastructure rather than maintaining local accounts on each unit.
Q: What is the monitoring capability of the VP4N31A1 — is it outlet-level or unit-level?
A: The VP4N31A1 provides unit-level monitoring, measuring current, voltage, and power at the PDU input. It does not provide per-outlet switching or per-outlet metering. For outlet-level switching or metering, consider a switched or metered-at-outlet variant in the Vertiv Geist rPDU family.
Q: Does the VP4N31A1 support Modbus TCP?
A: Yes. Modbus TCP is supported, enabling integration with building management systems (BMS), SCADA platforms, and DCIM tools that use Modbus as a data acquisition protocol alongside or instead of SNMP.

The VP4N31A1 sits squarely in the monitored-only tier — which is exactly right for deployments where you need load visibility and remote alerting but don't need per-outlet switching control. The 30A/208V single-phase input feeding 10 locking IEC outlets covers a typical compute row at 60–70% utilization with headroom, and the unit-level current/voltage/power monitoring gives NOC teams the data they need without the cost premium of a fully switched PDU.
Technical Highlights:
Deployment Considerations:
This PDU is a solid fit for enterprise co-location deployments standardizing on 208V/30A circuits where the primary requirement is NOC-visible load monitoring, AAA-integrated access control, and BMS/DCIM integration — without the per-outlet switching cost you'd pay for and never use on a stable compute row.