Vertiv
SKU: VP4N20A5
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VP4N21A2 is a single-phase, unit-level monitored rack PDU rated at 20A and 208V (3.3kW) with ten locking IEC C13 outlets — purpose-built for horizontal 0U rack deployment in data centers and server rooms where outlet-level visibility and remote power management matter. Feeding off a NEMA L6-20P plug and delivering current, voltage, and power monitoring over a full enterprise protocol stack, the VP4N21A2 gives operations teams the telemetry they need to avoid overloads and document capacity in real time. The 3-meter input cable provides enough reach to span most rack-to-PDU-distribution distances without patch extensions.
The VP4N21A2 connects to any rack power distribution management environment supporting SNMP, Modbus TCP, or HTTP/HTTPS-based interfaces. Its dual-stack IP support and full AAA protocol coverage (RADIUS, TACACS+, LDAP) make it straightforward to incorporate into enterprise data center fabrics already running structured Vertiv power infrastructure. DCIM platforms with native Modbus TCP drivers can poll this PDU directly for real-time capacity data. Pair with upstream UPS and power conditioning equipment on the same 20A 208V circuit to build a complete monitored power path from utility input to server inlet. For teams managing multiple racks, the SNMP v3 interface plugs into existing network management workflows without additional licensing overhead.
Q: What input plug does the VP4N21A2 use, and what circuit does it require?
A: The VP4N21A2 uses a NEMA L6-20P twist-lock plug and requires a 20A, 200–240V single-phase circuit (50/60 Hz). In North American data centers, this is typically a 208V 20A dedicated circuit from a PDU distribution panel or busway tap.
Q: Does the VP4N21A2 support SNMP v3?
A: Yes. The VP4N21A2 supports SNMP v1, v2c, and v3. SNMP v3 provides authentication and encryption, making it compatible with enterprise NMS environments that require secure polling without clear-text community strings.
Q: Can the VP4N21A2 integrate with RADIUS or TACACS+ for user authentication?
A: Yes. Both RADIUS and TACACS+ are supported network protocols on this PDU, allowing you to manage access credentials through your existing AAA infrastructure rather than maintaining local accounts on each device.
Q: What does 'unit-level monitored' mean for the VP4N21A2?
A: Unit-level monitoring means the PDU tracks and reports aggregate current, voltage, and power at the PDU input — not at each individual outlet. You can see total load on this PDU, but outlet-by-outlet switching or per-outlet metering requires a switched or outlet-monitored PDU model.
Q: Does the VP4N21A2 support Modbus TCP?
A: Yes. Modbus TCP is included in the supported protocol list, which allows direct integration with DCIM platforms and building management systems that use Modbus as their native communication protocol.
Q: How many rack units does the VP4N21A2 occupy?
A: The VP4N21A2 is a 0U horizontal PDU, meaning it mounts in a standard 1U rack space but its classification as 0U reflects that it is designed for the rear of the rack and does not consume vertical rack space intended for servers or active equipment.

The VP4N21A2 hits a specific deployment sweet spot: you want real-time power telemetry and enterprise AAA integration on a 208V 20A circuit, but you don't need per-outlet switching or individual outlet metering. The unit-level monitoring at 20A/3.3kW with SNMP v3 and Modbus TCP gives operations teams meaningful capacity data without paying for outlet-switched functionality most 1U server racks don't actually require.
Technical Highlights:
Deployment Considerations:
Best fit for colocation environments, enterprise server rooms, and edge deployments where a 208V 20A circuit feeds a mixed 1U/2U server population and the operations team needs SNMP-polled power data integrated into an existing NMS — without the cost or complexity of a fully switched PDU.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Vertiv products? Shop the full Vertiv catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price