Fire Alarm Modules

Sidebar
Selecting a sort option will reload the product list.

Showing Results for Fire Alarm Modules

  • DSC HSM2108 Hardwired Door Strike Monitor Module

    DSC

    SKU: HSM2108

    DSC HSM2108 Hardwired Door Strike Monitor Module

    Hardwired door strike monitor with real-time supervised status feedback

    • Hardwired door strike monitor module at 12VDC
    • DIN rail or panel cabinet mount for control panels
    • Monitors door strike state for access control logic
    $113.60 $51.99 Save $61.61
    The item has been added
    Free shipping over $499
    $113.60 $51.99 Save $61.61
    Add to quote
  • Potter CA2Z Class A Initiating Module (view 3)

    Potter

    SKU: CA2Z

    Potter CA2Z Class A Initiating Module

    Class A initiating module converts 4 Class B circuits for PFC panels

    • Converts four Class B initiating circuits to supervised Class A operation.
    • Built-in 5.1k EOL resistor eliminates external resistor packs and reduces wiring complexity.
    • 8-pin header mounts directly to PFC-4410RC and PFC-4410G3 panels using included hardware.
    $61.99
    The item has been added
    Free shipping over $499
    $61.99
    Add to quote
  • Potter CAM Class A Output Module

    Potter

    SKU: CAM

    Potter CAM Class A Output Module

    Relay-based Class A output module for door strike and accessory control

    • Relay-based Class A output drives door strikes and accessories at 12V or 24V DC.
    • Wiegand protocol support enables direct integration with standard credential readers.
    • Hardwired I/O architecture removes network dependency for critical door control functions.
    $81.75 $46.99 Save $34.76
    The item has been added
    Free shipping over $499
    $81.75 $46.99 Save $34.76
    Add to quote
  • Potter MRS Main Reserve Switch
    Add to Cart The item has been added

    Potter

    SKU: MRS

    Potter MRS Main Reserve Switch

    Key-operated main/reserve selector for fire suppression control systems

    • DPDT relay switches two signal pairs simultaneously, eliminating dead time during main/reserve changeover.
    • 1 A @ 40 VDC contact rating suits low-voltage fire alarm panel and solenoid valve control circuits.
    • Runs on 24 VDC at 10 mA, integrating directly into standard fire alarm panel power supplies.
    $117.99
    The item has been added
    Free shipping over $499
    $117.99
    Add to cart Add to quote
  • Potter PAD100-DIM Dual Input Module (view 2)
    Add to Cart The item has been added

    Potter

    SKU: PAD100-DIM

    Potter PAD100-DIM Dual Input Module

    Dual-input module expands Potter panel capacity with 2 RJ-45 reader ports

    • Two independent RJ-45 reader ports extend panel capacity without adding a second controller.
    • Supports Wiegand and serial protocols, enabling mixed legacy and modern reader deployments.
    • Compatible with proximity cards, smart cards, and PIN keypads from a single management point.
    $178.50 $113.99 Save $64.51
    The item has been added
    Free shipping over $499
    $178.50 $113.99 Save $64.51
    Add to cart Add to quote
  • Potter PAD100-IM Isolator Module (view 3)

    Potter

    SKU: PAD100-IM

    Potter PAD100-IM Isolator Module

    Power distribution isolator for multi-door access control networks

    • Isolates reader and strike power branches to contain faults and prevent cascade failures.
    • Operates across 32–120°F (0–49°C), supporting diverse indoor deployment environments.
    • UUKL Listed for Smoke Control; includes 5-year manufacturer warranty for project assurance.
    $119.00 $72.99 Save $46.01
    The item has been added
    Free shipping over $499
    $119.00 $72.99 Save $46.01
    Add to quote
  • Potter PAD100-LED Addressable LED Module
    Add to Cart The item has been added

    Potter

    SKU: PAD100-LED

    Potter PAD100-LED Addressable LED Module

    Addressable LED module for remote status feedback on single alarm line

    • Unique address assignment enables independent control of each module from the main panel.
    • Daisy-chain topology on one addressable line eliminates separate indicator wiring per zone.
    • UUKL listed for smoke control applications with a 5-year manufacturer warranty included.
    $66.30 $42.99 Save $23.31
    The item has been added
    Free shipping over $499
    $66.30 $42.99 Save $23.31
    Add to cart Add to quote
  • Potter PAD100-MIM Micro Input Module for security systems, front view

    Potter

    SKU: PAD100-MIM

    Potter PAD100-MIM Micro Input Module

    Micro input module for PAD100 systems—expand without a second controller

    • Expands PAD100 input capacity without adding a second full-size controller.
    • Fits a 2-1/2" deep single-gang box, making it viable for tight retrofit enclosures.
    • Communicates natively with PAD100 protocol—no middleware or extra programming needed.
    $90.55 $60.99 Save $29.56
    The item has been added
    Free shipping over $499
    $90.55 $60.99 Save $29.56
    Add to quote
  • Potter PAD100-RM Relay Expansion Module

    Potter

    SKU: PAD100-RM

    Potter PAD100-RM Relay Expansion Module

    Relay expansion module for Potter PAD series door control scaling

    • Expands Potter PAD series door capacity without replacing the existing controller.
    • Relay contacts rated 2A @30VDC and 0.5A @125VAC for strikes and mag-locks.
    • UUKL listed for smoke control with a 5-year manufacturer warranty included.
    $135.70 $87.99 Save $47.71
    The item has been added
    Free shipping over $499
    $135.70 $87.99 Save $47.71
    Add to quote
  • Potter PAD100-SIM Single Input Module
    Add to Cart The item has been added

    Potter

    SKU: PAD100-SIM

    Potter PAD100-SIM Single Input Module

    Single input module for Potter access control—expand without replacing controllers

    • Adds a dedicated input channel to exhausted Potter controllers without replacing hardware.
    • Supports Wiegand and clock-and-data reader protocols, avoiding single-vendor lock-in.
    • UUKL Listed for Smoke Control with a 5-year warranty included in the package.
    $110.70 $71.99 Save $38.71
    The item has been added
    Free shipping over $499
    $110.70 $71.99 Save $38.71
    Add to cart Add to quote
  • Potter PAD100-TRTI Two Relay Two Input Module (view 2)
    Add to Cart The item has been added

    Potter

    SKU: PAD100-TRTI

    Potter PAD100-TRTI Two Relay Two Input Module

    Two relay two input module expands Potter access control without panel swap

    • Adds two independent relay outputs for strikes or maglocks without intermediate relays.
    • Two discrete inputs monitor door position sensors, REX buttons, or dry-contact devices.
    • Terminal block wiring enables retrofit installs with no proprietary connectors or special tools.
    $433.25 $279.99 Save $153.26
    The item has been added
    Free shipping over $499
    $433.25 $279.99 Save $153.26
    Add to cart Add to quote
  • Potter PAD100-ZM Zone Expansion Module
    Add to Cart The item has been added

    Potter

    SKU: PAD100-ZM

    Potter PAD100-ZM Zone Expansion Module

    Zone expansion module for Potter systems—add I/O without replacing panels

    • Adds reader and strike I/O to existing Potter panels without hardware replacement.
    • Operates as a networked slave device, keeping credential policy centrally managed.
    • UUKL Listed for Smoke Control and backed by a 5-year manufacturer warranty.
    $173.70 $110.99 Save $62.71
    The item has been added
    Free shipping over $499
    $173.70 $110.99 Save $62.71
    Add to cart Add to quote
  • Potter RA-4410G3 wireless security control panel system

    Potter

    SKU: RA-4410G3

    Potter RA-4410G3

    Multi-credential reader with sub-second response for access control systems

    • Supports multiple credential formats, enabling retrofits without replacing existing cards.
    • Sub-second credential processing sustains high-throughput access in busy commercial doorways.
    • Encrypted and standard transmission support lets you match protocol to site security policy.
    $666.25 $340.99 Save $325.26
    The item has been added
    Free shipping over $499
    $666.25 $340.99 Save $325.26
    Add to quote
  • System Sensor COSMOD2W i4 Series 2-Wire Interface Module

    System Sensor

    SKU: COSMOD2W

    System Sensor COSMOD2W i4 Series 2-Wire Interface Module

    2-wire interface module for fire alarm system integration at 35VDC

    • Operates at 35VDC for direct integration with conventional fire alarm control panels.
    • 2-wire protocol support simplifies retrofit wiring into existing detection architectures.
    • Compact form factor mounts in standard electrical enclosures without dedicated power drops.
    $112.47 $74.99 Save $37.48
    The item has been added
    Free shipping over $499
    $112.47 $74.99 Save $37.48
    Add to quote
  • System Sensor COSMOD4W i4 Series 4-Wire Interface Module
    Add to Cart The item has been added

    System Sensor

    SKU: COSMOD4W

    System Sensor COSMOD4W i4 Series 4-Wire Interface Module

    i4 Series 4-wire interface module for addressable fire detection networks

    • Bridges 4-wire detection circuits into i4 Series addressable networks without rewiring.
    • Operates at 35VDC, enabling direct integration with i4 Series loop power supplies.
    • Supports i3 Series detectors and multi-panel distributed fire safety deployments.
    $109.78 $71.99 Save $37.79
    The item has been added
    Free shipping over $499
    $109.78 $71.99 Save $37.79
    Add to cart Add to quote
  • System Sensor D4P120 Duct Detector Power Board Component (view 2)

    System Sensor

    SKU: D4P120

    System Sensor D4P120 Duct Detector Power Board Component

    TCP/IP duct detector power board, 29VDC output for System Sensor assemblies

    • Supplies regulated 29VDC to photoelectric sensor heads in D4120 duct detector assemblies.
    • Operates across –4°F to 158°F, supporting installations in harsh mechanical environments.
    • ¾-inch conduit knockout and terminal-block wiring simplify 4-wire field connections.
    $251.77 $156.99 Save $94.78
    The item has been added
    Free shipping over $499
    $251.77 $156.99 Save $94.78
    Add to quote

Fire Alarm Modules

Addressable fire alarm input/output modules for SLC loop expansion. Monitor modules supervise conventional zones and contact inputs; relay modules control HVAC shutdown, door holders, and elevator recall; isolator modules protect SLC loops from short-circuit faults.

Plan Your Deployment

  • Select module type: monitor (input), relay (output), control, or isolator based on function
  • Confirm SLC protocol compatibility with installed fire alarm panel platform
  • Plan isolator module placement per NFPA 72 to limit fault impact on the loop
  • Specify relay contact rating for HVAC shutdown, door holder, and elevator recall loads
  • Evaluate dual-input monitor modules to reduce SLC address consumption

Fire Alarm Modules — Engineering-Grade Fire Detection for Commercial Deployments

This category covers 12 working models of fire alarm modules sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.

What to Look For

Addressable versus conventional architecture is the first decision. Conventional systems group detectors into zones; addressable systems identify the exact device that triggered. For buildings above 10,000 sq ft or with more than 20 detectors, addressable saves substantial diagnostic time and meets most modern code requirements. Conventional panels remain economical for small commercial buildings and retrofits where new wiring isn't feasible.

UL 864 listing is non-negotiable for the panel; UL 268 for smoke detectors, UL 521 for heat detectors. The AHJ will reject anything else. Beyond UL, look for FM Approval and CSFM (California) listings — many jurisdictions accept only those. Confirm panel-to-detector compatibility within the manufacturer's listed combinations; mixing brands across UL listings voids the panel's certification.

Notification appliance circuit (NAC) capacity, voltage drop, and battery backup sizing drive panel sizing more than detector count does. ADA-compliant strobes draw 75-175 mA each — a 50-strobe building exceeds many small NAC ratings. Calculate total NAC load with voltage-drop budget for the longest run, and size standby battery for 24 hours plus 5 minutes alarm per NFPA 72.

Central station communication, networked panel federation, and graphical workstations matter most in multi-building campuses. Single-building panels typically dial a central station via cellular and IP; multi-building campuses run proprietary peer-to-peer networks (Notifier NFN, Siemens FN-2127, Edwards SIGA) with master annunciation. Plan the integration topology before ordering panels — head-end choice affects which compatible peripherals you can deploy.

Key Specs in This Category

SpecAvailable Options
TypeModule, Class A Output Module, Switch, Controller, Isolator Module, Monitor, Micro Input Module, Relay expansion module

Top Brands in This Category

Frequently Asked Questions

Do I need an addressable or conventional fire alarm panel?

Addressable panels identify the specific detector in alarm; conventional panels identify only the zone. NFPA 72 and most local codes require addressable for buildings above certain occupancy or square-footage thresholds, but the practical break-even is around 20-30 detectors. Above that count, addressable saves diagnostic and maintenance time. Below it, conventional is often the budget-friendly choice.

What's the difference between photoelectric and ionization smoke detectors?

Photoelectric detectors respond fastest to smoldering fires (cigarettes, electrical wiring); ionization detectors respond fastest to flaming fires (paper, kitchen). Modern dual-sensor detectors include both technologies and meet UL 268 7th edition requirements. Most jurisdictions now require dual-sensor or photoelectric for new commercial installations. Ionization-only is being phased out due to nuisance-alarm performance in cooking and shower-steam scenarios.

How often must fire alarm systems be inspected?

NFPA 72 requires annual inspection and testing of the entire system, semiannual battery testing, and monthly visual inspection of the panel. Local AHJ requirements often mandate documentation and a service contract with a licensed contractor. The owner-of-record bears legal responsibility for inspections — missing an annual inspection exposes the owner to fines and insurance claim denial.

Do I need a duct smoke detector?

Yes if the HVAC system exceeds 2,000 CFM (commercial threshold) — code requires duct smoke detectors that shut down the HVAC to prevent smoke distribution during a fire. Confirm CFM rating against local code thresholds; many jurisdictions require duct detection on smaller systems serving multiple-occupancy buildings. Duct detectors must report to the building's fire alarm panel.

What battery backup is required for fire panels?

NFPA 72 requires 24 hours of standby operation plus 5 minutes in full alarm. Calculate panel current draw under both conditions, then specify a battery with adequate Ah capacity. Lead-acid batteries lose capacity in cold environments — derate by 20% for unconditioned spaces. Replace batteries every 4-5 years even if they test good; failure rates climb steeply after year 5.

Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.