Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

System Sensor COSMOD2W 2-Wire Interface Module

Overview

The System Sensor COSMOD2W is a 2-wire interface module for fire alarm system signal conditioning and equipment integration in commercial and industrial fire detection architectures. Operating at 35VDC, the COSMOD2W translates control signals between fire detection equipment and panel systems in retrofit and new-build installations where 2-wire protocol interfaces are required. Compact form factor supports standard electrical enclosure mounting and field deployment without requiring dedicated power drops.

Compatibility

The COSMOD2W integrates into System Sensor i4 Series fire alarm system architectures and control panels requiring 2-wire signal conditioning. Designed for retrofit applications where existing detection equipment must communicate with legacy or conventional analog fire alarm control systems. Consult the specific fire alarm control panel documentation to confirm protocol compatibility before installation.

Installation Notes

Operating voltage is 35VDC — verify your fire alarm control panel supply voltage before wiring. Module is rated for panel mounting in standard electrical enclosures; secure with appropriate fasteners for vibration environments. Connect 2-wire signal inputs and outputs following terminal markings on the module housing. Environmental operating limits and temperature range are standard for indoor commercial fire alarm equipment — avoid moisture-prone locations unless the enclosure is rated for the environment. No external power supply is required; the module draws power directly from the panel's 35VDC supply line.

Specifications
Product Type: Fire alarm interface module
Communication: 2-Wire Protocol
Voltage: 35VDC
Type: i4 Series 2-Wire Interface Module
Warranty: Manufacturer Warranty
Package Contents: current draw from attached detectors or EOL relay.; **Does not include reverse polarity current draw from attached detectors.; 100 Series™ Plug-In Smoke Detectors and Bases
Analytics: Smoke Detection
Mount Type: Wall; Ceiling
Mounting: Red Model No. White Model No. Description
weight: 0.57
Operating System: Y2 Used to monitor the open position of an 1 in. to 12 in. 10 A @ 125/250 VAC; —
product_type: Reader
Operating_System: Y2 Used to monitor the open position of an 1 in. to 12 in. 10 A @ 125/250 VAC; —
Compatible With: fire
Product_Type: 2-Wire Interface Module
Q&A
Reviews
Have Questions?

System Sensor COSMOD2W i4 Series 2-Wire Interface Module

$112.47
$76.99

RELATED PRODUCTS

Save $35.79
System Sensor COSMOD4W i4 Series 4-Wire Interface Module
Add to Cart The item has been added

System Sensor COSMOD4W

System Sensor COSMOD4W i4 Series 4-Wire Interface Module

i4 Series 4-wire interface module for addressable fire detection networks

  • Bridges 4-wire detection circuits into i4 Series addressable networks without rewiring.
  • Operates at 35VDC, enabling direct integration with i4 Series loop power supplies.
  • Supports i3 Series detectors and multi-panel distributed fire safety deployments.
Usually Ships in 2-3 Weeks Free shipping over $499
$109.78 $73.99 Save $35.79
The item has been added Add to quote
$109.78 $73.99 Save $35.79
Save $35.79 Add to cart Add to quote
Save $73.65
System Sensor COSMO-2W i4 Series 2-Wire CO/Smoke Detector with Sounder (view 3)
Add to Cart The item has been added

System Sensor COSMO-2W

System Sensor COSMO-2W i4 Series 2-Wire CO/Smoke Detector with Sounder

Dual smoke/CO detector on single 2-wire loop with integrated sounder

  • Photoelectric smoke and electrochemical CO sensing share one 2-wire loop address.
  • Integrated sounder eliminates external horn modules, reducing device count per zone.
  • Mounts to 3.5"/4" octagonal, single-gang, 4" square, or round ceiling boxes.
Usually Ships in 2-3 Weeks Free shipping over $499
$220.64 $146.99 Save $73.65
The item has been added Add to quote
$220.64 $146.99 Save $73.65
Save $73.65 Add to cart Add to quote
Save $23.41
System Sensor RRS-MOD i3 Series Reversing Relay Synchronization Module
Add to Cart The item has been added

System Sensor RRS-MOD

System Sensor RRS-MOD i3 Series Reversing Relay Synchronization Module

TCP/IP reversing relay module for i3 Series networked fire alarm systems

  • TCP/IP communication integrates directly into networked fire alarm architectures without added signal wiring.
  • 35VDC operating voltage aligns with standard fire alarm power distribution, eliminating auxiliary supplies.
  • Bidirectional relay switching enables distinct actuation logic for alarm and reset/evacuation scenarios.
Usually Ships in 2-3 Weeks Free shipping over $499
$79.40 $55.99 Save $23.41
The item has been added Add to quote
$79.40 $55.99 Save $23.41
Save $23.41 Add to cart Add to quote
Save $151.01
System Sensor D2 2-Wire Photoelectric Duct Smoke Detector (view 2)
Add to Cart The item has been added

System Sensor D2

System Sensor D2 2-Wire Photoelectric Duct Smoke Detector

Photoelectric duct detector, 2-wire conventional, 29VDC for HVAC systems

  • Photoelectric sensing reliably detects smoldering fires in HVAC ductwork.
  • 2-wire circuit cuts conduit runs—power and signaling share one wire pair.
  • 29VDC operation integrates with legacy and modern panels without added modules.
Usually Ships in 2-3 Weeks Free shipping over $499
$303.00 $151.99 Save $151.01
The item has been added Add to quote
$303.00 $151.99 Save $151.01
Save $151.01 Add to cart Add to quote
Save $0.92
System Sensor PR-1 Single Relay Module (view 2)
Add to Cart The item has been added

System Sensor PR-1

System Sensor PR-1 Single Relay Module

Single relay module for fire alarm system expansion across multi-voltage setups

  • Single relay output expands auxiliary control channels for locks, strobes, or dampers.
  • Multi-voltage input eliminates power conditioning hardware in mixed-voltage installations.
  • Relay contacts integrate third-party access control and signaling devices via standard switching.
Usually Ships in 2-3 Weeks Free shipping over $499
$30.91 $29.99 Save $0.92
The item has been added Add to quote
$30.91 $29.99 Save $0.92
Save $0.92 Add to cart Add to quote

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources