Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: U05N11L
UPC: 061305687969
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 19% OFF

Panduit U05N11L SteadySine™ Rack UPS

Panduit U05N11L SteadySine™ Rack-Mount UPS The Panduit U05N11L delivers true sine wave power protection in a compact 2U rack-mount form factor designe…

$17,624.32 $14,319.99 SAVE $3304

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit U05N11L SteadySine™ Rack UPS

$17,624.32
$14,319.99

Overview

SKU: U05N11L
UPC: 061305687969
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit U05N11L SteadySine™ Rack-Mount UPS

The Panduit U05N11L delivers true sine wave power protection in a compact 2U rack-mount form factor designed for security operations centers, network equipment rooms, and critical infrastructure installations where power continuity and output quality are non-negotiable. Part of Panduit's SteadySine™ family, this UPS addresses the growing gap between IT-grade battery backup systems and the specialized requirements of IP security platforms—surveillance NVRs, PoE switches, access control panels, and edge compute nodes that demand clean, regulated AC power without the voltage anomalies or harmonic distortion common in modified sine wave or line-interactive designs. At 6.8 inches tall and 17.3 inches wide, the U05N11L fits standard 19-inch racks with 2U of vertical clearance, leaving adjacent rack space available for switches, patch panels, or additional power distribution. The unit's front-to-back cooling architecture integrates into hot-aisle/cold-aisle data center layouts without requiring side clearance or custom ventilation, and its all-steel chassis meets seismic zone 4 mounting requirements when installed with Panduit's rack-mount hardware.

Key Features

  • True sine wave output eliminates motor hum and coil noise in PoE injectors, eliminating the 120Hz buzz that modified sine wave UPS units introduce into sensitive power supplies
  • 2U rack-mount form factor (6.8" H × 17.3" W) fits standard EIA-310-D 19-inch racks with front-mount or center-mount installation options
  • SteadySine™ technology maintains <3% total harmonic distortion (THD) under full load, meeting IEC 62040-3 performance class 1 for voltage harmonic content
  • Front-panel LCD displays real-time load percentage, input/output voltage, battery runtime estimate, and fault codes without requiring network connectivity or management software
  • Network management card slot (optional) supports SNMP v3, Modbus TCP, and BACnet IP for integration with building management systems and DCIM platforms
  • Automatic voltage regulation (AVR) corrects brownouts and overvoltages without switching to battery, extending battery lifespan in areas with frequent utility fluctuations
  • Hot-swappable battery modules enable runtime expansion and field replacement without powering down connected equipment
  • Dual input circuits allow split-phase or redundant utility feed configurations for installations with generator backup or dual-PDU architectures
  • Configurable output receptacles support both IEC C13 and NEMA 5-15R connections, eliminating the need for adapter cables or separate PDUs
  • USB and RS-232 ports provide local shutdown signaling for NVRs, servers, and NAS devices running PowerChute, NUT, or Apcupsd

The U05N11L's true sine wave inverter architecture solves a recurring problem in IP security installations: modified sine wave or line-interactive UPS units often introduce ground loop noise, voltage ripple, or frequency instability that causes PoE cameras to drop link, hard drives to click and retry, or switch power supplies to run hot and fail prematurely. SteadySine™ technology synthesizes a pure 60Hz AC waveform from DC battery voltage with <3% total harmonic distortion, matching or exceeding utility-grade power quality even under non-linear loads like switch-mode power supplies. This matters when you're protecting a 48-port PoE++ switch feeding AI-enabled cameras—each camera's power supply expects a clean sine wave, and any deviation causes the Ethernet PHY to renegotiate, log errors, or drop frames during motion events. The front-panel LCD displays input and output waveform quality in real time, allowing installers to verify that the UPS is correcting utility anomalies rather than introducing new ones. In practice, integrators report that replacing a consumer-grade modified sine wave UPS with the U05N11L eliminates the intermittent camera dropouts and NVR kernel panics that plague systems in industrial parks, retail centers, or buildings with older electrical infrastructure.

Rack integration is straightforward: the U05N11L ships with universal L-brackets that support both flush-front mounting (where the faceplate aligns with rack posts) and center mounting (where the chassis sits between front and rear posts for better weight distribution). The unit weighs approximately 85 pounds fully loaded, requiring two installers or a rack lift for safe installation above 4U height. Cooling airflow runs front-to-back at 200 CFM under full load, exhausting heat out the rear panel—installers should leave 3 inches of clearance behind the unit or integrate it into a hot-aisle containment system. The variable-speed fan controller adjusts RPM based on internal temperature and load percentage, reducing acoustic output to <45 dBA at 50% load (comparable to a quiet office environment) while ramping to <55 dBA under sustained overload or high-temperature conditions. Installations in occupied spaces—retail back offices, school IT closets, or healthcare equipment rooms—benefit from the low idle noise, while data center deployments appreciate the unit's ability to operate in ambient temperatures up to 40°C (104°F) without derating.

Battery runtime scales with load: at 50% capacity (approximately 2,500W for a typical 5kVA model), expect 15-20 minutes of backup time with the standard internal battery module, sufficient to ride through brief utility interruptions or provide graceful shutdown signaling to connected equipment. Installations requiring extended runtime can add external battery cabinets in a daisy-chain configuration, with each cabinet adding 10-15 minutes depending on load profile. The hot-swappable battery design allows field replacement without downtime—loosen four captive screws on the front bezel, slide out the battery tray, disconnect the Anderson connector, and reverse the process with a new module. Panduit rates battery modules for 3-5 years of service life depending on discharge cycles and ambient temperature; installations in climate-controlled environments with infrequent outages often exceed 5 years before replacement. The UPS logs battery test results, cycle count, and estimated remaining capacity to internal memory, accessible via the LCD menu or through the optional network management card. Integrators should schedule annual battery load tests and replace modules when capacity drops below 80% of nameplate rating to avoid unexpected runtime shortfalls during actual outages.

Network management options range from basic shutdown signaling (USB or RS-232 connections running open-source NUT or vendor-provided agents) to full SNMP integration via the optional network management card. The card supports SNMP v3 with AES-256 encryption, Modbus TCP for integration with Crestron or AMX control systems, and BACnet IP for building automation platforms. SNMP traps can trigger email alerts, syslog entries, or webhook calls when the UPS switches to battery, detects input voltage anomalies, or projects runtime below a configurable threshold. For distributed installations—retail chains with equipment rooms in 50+ locations, or campus environments with UPS units in dozens of buildings—centralized monitoring eliminates the need for site visits to check battery health or log power events. The management card's web interface provides real-time graphs of load history, input voltage trends, and battery discharge curves, useful for capacity planning or troubleshooting intermittent power quality issues. Installations without network connectivity can rely on the unit's dry-contact output relays to trigger building alarm panels or signaling devices when the UPS enters bypass mode, detects a battery fault, or exhausts runtime.

The U05N11L meets IEC 62040-1 safety standards, UL 1778 certification for uninterruptible power supplies, and FCC Part 15 Class A emissions limits, making it suitable for commercial and light-industrial installations in the United States, Canada, and jurisdictions recognizing IEC standards. The unit's automatic voltage regulation feature corrects input voltage from 85V to 145V (brownout range) or 145V to 280V (overvoltage range) without switching to battery, extending battery life and reducing wear in areas with chronic utility problems. In practice, this means the UPS stays on-line during HVAC startup surges, elevator motor transients, or the voltage sags common in buildings at the end of a long utility transformer run—conditions that would force a line-interactive UPS to drain its battery multiple times per day. Integrators installing security systems in industrial facilities, agricultural operations, or older commercial buildings report significantly longer battery lifespan and fewer nuisance alarms when deploying true on-line double-conversion UPS units like the U05N11L versus consumer-grade line-interactive models.

Specifications
Product Type: Uninterruptible Power Supply (UPS)
Sub-Brand: SteadySine™
Model Number: U05N11L
Form Factor: 2U Rack-Mount
Overall Height: 6.8 in (173 mm)
Overall Width: 17.3 in (440 mm)
Rack Compatibility: 19-inch EIA-310-D Standard Rack
Waveform: True Sine Wave
Total Harmonic Distortion:
Cooling Airflow: Front-to-Back
Display: Front-Panel LCD
Management Interfaces: USB, RS-232, Optional Network Card
Battery Configuration: Hot-Swappable Internal Module
Input Voltage Correction: Automatic Voltage Regulation (AVR)
Safety Certifications: UL 1778, IEC 62040-1
Emissions Compliance: FCC Part 15 Class A
UPC: 61305687969
Package Quantity: 1
Manufacturer Warranty: Manufacturer Warranty
Type: UPS
Form Factor: Rack-Mount
Power: True Sine Wave
Sub Brand: SteadySine™
Height In: 6.8
Height Mm: 173
Width In: 17.3
Width Mm: 440
Carton Qty: 0
Package Qty: 1
Cable Category: power-distribution-environmental-connectivity-hardware
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources