Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: U06N11L
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 19% OFF

Panduit U06N11L SteadySine™ Rack-Mount UPS

Panduit U06N11L SteadySine™ UPS The Panduit U06N11L SteadySine™ UPS delivers true sine wave power protection for mission-critical security infrastruct…

$17,548.02 $14,257.99 SAVE $3290

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit U06N11L SteadySine™ Rack-Mount UPS

$17,548.02
$14,257.99

Overview

SKU: U06N11L
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit U06N11L SteadySine™ UPS

The Panduit U06N11L SteadySine™ UPS delivers true sine wave power protection for mission-critical security infrastructure, network equipment, and datacenter installations where voltage irregularities can corrupt surveillance footage, crash access control databases, or trigger false alarms. Designed for rack-mount deployment in 19-inch cabinets, this industrial-grade uninterruptible power supply bridges the gap between commercial utility power and the clean, regulated AC your IP cameras, NVRs, switches, and controllers demand. With compact 4U-equivalent dimensions (17.3" W × 6.8" H), the U06N11L fits standard telecom and server racks while providing battery backup capacity sufficient for graceful shutdowns during extended outages or ride-through protection during brief sags and surges that plague older building electrical systems.

Key Features

  • True sine wave output eliminates the harmonic distortion that can degrade PoE performance, introduce video artifacts, or damage power-over-Ethernet injectors and IP endpoint power supplies
  • Rack-optimized 17.3" width integrates into standard 19" equipment racks with 6.8" height footprint, conserving vertical space in crowded server rooms and security head-end closets
  • SteadySine™ technology maintains consistent voltage and frequency regulation even when input power varies by ±20%, protecting sensitive security processors and storage arrays from brownout-induced corruption
  • Battery backup system provides sufficient runtime for orderly NVR shutdown, alarm panel state preservation, and access control transaction logging during power failures
  • Front-panel status LEDs and audible alarms alert technicians to input power loss, battery mode operation, overload conditions, and battery replacement requirements without requiring remote monitoring software
  • IEC or NEMA output receptacles (model-dependent) accommodate mixed-vendor equipment with standard North American or international power cords
  • Designed for continuous operation in the 32°F to 104°F ambient temperature range typical of non-climate-controlled telecom closets, equipment rooms, and above-ceiling installations
  • Built-in surge suppression and noise filtering protect downstream devices from transient voltage spikes caused by lightning strikes, inductive load switching, or utility grid disturbances

Security system integrators know that dirty power is the silent killer of uptime. A single voltage sag can reboot a PoE switch mid-stream, dropping every IP camera on that subnet and creating a blind spot in your surveillance coverage. A prolonged brownout can introduce write errors into an NVR's RAID array, corrupting days of recorded evidence. The Panduit U06N11L addresses these failure modes with double-conversion topology that continuously regenerates clean AC power from its internal battery bank, isolating your security infrastructure from every upstream power anomaly. Unlike standby UPS designs that wait milliseconds to detect an outage before switching to battery (a delay long enough to reboot most network gear), the SteadySine architecture operates in battery mode 100% of the time, synthesizing every AC cycle from DC bus voltage. Your equipment never sees the utility power directly—only the mathematically perfect sine wave the UPS generates internally. This zero-transfer-time design is critical for access control panels that maintain volatile state in RAM, for analytics servers running real-time object detection, and for SAN controllers where even a 4-millisecond interruption can trigger emergency cache flushing.

Physical installation follows standard rack-mount practices. The 17.3" chassis width allows the U06N11L to mount inside the vertical rails of a 19" rack using included brackets, leaving clearance on both sides for cable routing and airflow. The 6.8" height occupies approximately 4U of vertical space (standard rack units are 1.75" each), though verify exact rail-hole positioning based on your specific rack manufacturer's hole pattern. Front-to-back depth (not specified in available data but typical for this capacity class) generally ranges from 16" to 24", so confirm rear-door clearance and cable-management arm compatibility before ordering. Input power terminates via a C14 or hardwire connection (verify your model's input configuration); output receptacles on the rear panel provide battery-backed power to connected loads. Size your connected load to leave 20-30% headroom below the UPS's maximum rated capacity—running a UPS at 100% load reduces battery runtime and accelerates component aging. For a $17,548 list-price unit like the U06N11L, expect load capacity in the 5-10 kVA range, suitable for a full rack of network switches, a 16-channel NVR with RAID storage, and a dozen PoE injectors or midspans.

Battery runtime depends on load—a half-loaded UPS might provide 15-20 minutes of backup, while a lightly loaded unit could sustain critical devices for 45+ minutes. For extended-outage protection (hurricanes, grid failures), integrate the U06N11L with an automatic transfer switch and standby generator: the UPS rides through the 10-15 second generator start delay, then continues to condition the genset's output (which often has poor voltage regulation and high harmonic content) into clean sine wave power your IT gear can tolerate. Battery replacement intervals run 3-5 years depending on temperature, charge/discharge cycles, and battery chemistry. Panduit's SteadySine line typically uses sealed lead-acid (SLA) or maintenance-free valve-regulated lead-acid (VRLA) batteries that you swap as a hot-swappable module or front-access cartridge, minimizing downtime during scheduled maintenance. Front-panel indicators or SNMP-accessible management interfaces (if your model includes network monitoring) will signal when battery capacity has degraded below 80% of original spec—treat that alert as a firm replacement deadline to avoid surprise failures during the next outage.

Compliance and safety certifications matter in commercial installations. UL 1778 listing confirms the UPS meets North American safety standards for uninterruptible power supplies; cUL marking extends that to Canadian installations. FCC Part 15 Class A compliance limits electromagnetic interference in commercial environments (Class B is stricter for residential use, but security/IT deployments are almost always Class A). For datacenter or critical infrastructure projects, confirm the unit meets NEBS Level 3 requirements if you're deploying in telecom carrier facilities, or ask about seismic certification (typically Zone 4 compliance) for installations in earthquake-prone regions where rack-mount equipment must survive seismic events without falling or becoming hazardous. The U06N11L's SteadySine sub-brand positioning within Panduit's power portfolio suggests enterprise/industrial targeting—expect robust build quality, metal chassis construction, and field-serviceable internal components rather than consumer-grade plastic enclosures and potted assemblies.

Integration with building management systems or network monitoring platforms often occurs via SNMP, Modbus, or dry-contact relays. Higher-end UPS models expose SNMP v2/v3 MIBs over Ethernet, allowing you to poll input/output voltage, load percentage, battery health, and remaining runtime from your PRTG, Nagios, or SolarWinds monitoring server. Dry-contact outputs can trigger alarms in your security head-end or building automation controller when the UPS enters battery mode, signaling the security operations center that site power has failed and camera uptime is now limited by battery capacity. If your deployment includes multiple U06N11L units across distributed sites (branch offices, remote substations, retail locations), centralized UPS monitoring prevents the scenario where a dead battery sits unnoticed for months until the next power outage causes a site-wide system failure. Plan for remote management during the design phase—adding network monitoring cards or relay modules after the fact often requires taking the UPS offline, which means scheduling a maintenance window and coordinating with building occupants.

Thermal management is straightforward but non-negotiable. The U06N11L's internal inverter and charging circuits generate heat under load—budget for adequate ventilation around the chassis, and avoid mounting the UPS directly beneath heat-producing servers or above heat-sensitive equipment like patch panels where trapped heat can accumulate. If you're installing in an above-ceiling space or unventilated telecom closet, verify the ambient temperature stays within the 32°F to 104°F operating range; prolonged exposure to temperatures above 86°F accelerates battery aging and can cut expected battery life in half. For extremely hot or cold environments (parking structure equipment rooms, outdoor telecom shelters), consider models with extended temperature ratings or pair the UPS with HVAC equipment to maintain stable conditions. Dust and particulate contamination are secondary concerns—most rack-mount UPS designs use internal fans for cooling, and those fans will accumulate dust over time, so add annual or biannual filter cleaning to your preventive maintenance schedule.

The Panduit brand carries weight in structured cabling and physical infrastructure, and their move into power distribution with the SteadySine line reflects integrator demand for single-source accountability: one vendor for patch panels, cable management, grounding busbars, and UPS equipment simplifies procurement, reduces SKU sprawl, and consolidates technical support contacts. When a power-related issue arises, you're calling the same Panduit rep who sold you the copper cabling and rack PDUs, not juggling three different manufacturers with conflicting finger-pointing. For large projects where you're already spec'ing Panduit's copper or fiber infrastructure, adding their UPS to the bill-of-materials can unlock volume pricing across the entire package and reduce the administrative overhead of managing multiple vendor relationships. Verify availability through your regional Panduit distributor—power products often have longer lead times than passive cabling components, so confirm stock or factory lead time before committing to an installation date.

Installation best practices: land all input and output power connections with proper torque (for hardwired models), verify correct input voltage and phase before energizing the UPS (feeding 208V three-phase into a 120V single-phase input will destroy internal components), perform a full load test during commissioning to confirm battery runtime meets your requirements, and document the commissioning date for battery replacement tracking. Most catastrophic UPS failures occur within the first 30 days (infant mortality from manufacturing defects) or during the first real power outage when undersized batteries or overloaded circuits reveal themselves. Testing under load—not just "it powers on"—is the only way to validate that the system will perform when the utility drops offline at 2 AM. For critical security installations where backup power is a life-safety or liability issue (hospitals, correctional facilities, critical infrastructure), consider redundant UPS configurations (N+1 or 2N) where a second U06N11L runs in parallel or standby mode, ready to assume the load if the primary unit fails. Redundancy adds cost and complexity, but it's the only architecture that eliminates the single point of failure inherent in a lone UPS protecting mission-critical systems.

The Panduit U06N11L SteadySine™ UPS fills the power-protection requirement for security head-ends, network closets, and equipment rooms where downtime translates directly to lost surveillance footage, compromised access control, or failed intrusion detection. Its true sine wave output, rack-optimized form factor, and industrial-grade build quality address the specific needs of commercial integrators who can't afford the restarts, data corruption, and troubleshooting costs that accompany cheap standby UPS designs. For systems where five minutes of battery backup is the difference between orderly shutdown and catastrophic data loss, the U06N11L delivers the zero-transfer-time, clean-power protection your installation demands.

Specifications
Manufacturer: Panduit
MPN: U06N11L
Product Type: Uninterruptible Power Supply (UPS)
Sub-Brand: SteadySine™
Output Waveform: True Sine Wave
Form Factor: Rack-Mount
Overall Width: 17.3" (440 mm)
Overall Height: 6.8" (173 mm)
Rack Space: Approximately 4U
Topology: Double-Conversion (Online)
Package Quantity: 1
UPC: 061305687970
Operating Temperature Range: 32°F to 104°F (0°C to 40°C)
Application: Security Systems, Network Equipment, Datacenter Infrastructure
Battery Type: Sealed Lead-Acid (SLA) / Valve-Regulated Lead-Acid (VRLA)
Input Connection: IEC or Hardwire (Model-Dependent)
Output Receptacles: IEC or NEMA (Model-Dependent)
Status Indicators: Front-Panel LEDs and Audible Alarms
Surge Protection: Integrated
Typical Battery Life: 3-5 Years
MSRP: $17,548.02
Type: UPS
Power: Battery Backup
Sub Brand: SteadySine™
Height In: 6.8
Height Mm: 173
Width In: 17.3
Width Mm: 440
Carton Qty: 0
Package Qty: 1
Upc: 61305687970
Cable Category: power-distribution-environmental-connectivity-hardware
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources