UPS & Power Management
Showing Results for UPS & Power Management
-
APC by Schneider Electric
SKU: SMX2KR2UNCX145
APC Smart-ups X Line Interactive 2000VA Rack/tower Convertible 2U 100V-127V - SMX2KR2UNCX145
In stock · Ships same business day$3,460.00 $2,302.99 Save $1,157.01 -
APC by Schneider Electric
SKU: SMX2200RMLV2U
APC Smart-ups X Line Interactive 2200VA Rack/tower Convertible 2U 100V-127V - SMX2200RMLV2U
In stock · Ships same business day$3,290.00 $2,190.99 Save $1,099.01 -
APC by Schneider Electric
SKU: SMX2200RMLVUS
APC Smart-ups X Line Interactive 2200VA Rack/tower Convertible 2U 100V-127V - SMX2200RMLVUS
In stock · Ships same business day$3,565.00 $2,371.99 Save $1,193.01 -
APC by Schneider Electric
SKU: SMX2200RMHV2U
APC Smart-ups X Line Interactive 2200VA Rack/tower Convertible 2U 208V-230V - SMX2200RMHV2U
In stock · Ships same business day$4,065.00 $2,705.99 Save $1,359.01 -
APC by Schneider Electric
SKU: SMX3000RMLVUS
APC Smart-ups X Line Interactive 3KVA Rack/tower Convertible 2U 100V-127V 3 - SMX3000RMLVUS
In stock · Ships same business day$4,335.00 $2,885.99 Save $1,449.01 -
APC by Schneider Electric
SKU: SMX750I
APC Smart-ups X Line Interactive 750VA Rack/tower Convertible 2U 230V 8X C1 - SMX750I
In stock · Ships same business day$1,340.00 $901.99 Save $438.01 -
APC by Schneider Electric
SKU: SMX120BP
APC Smart-ups X-series External Battery Pack Rack/tower 120V 1200VAH Rackmount - SMX120BP
In stock · Ships same business day$1,550.00 $732.99 Save $817.01 -
APC by Schneider Electric
SKU: SUA3000RMXLI3U
APC Smart-ups XL 3000VA RM 3U 230V - SUA3000RMXLI3U
In stock · Ships same business day$2,665.00 $1,798.99 Save $866.01 -
APC by Schneider Electric
SKU: SUA48RMXLBP3U
APC Smart-ups XL 48V RM 3U Battery Pack - Rack-mountable - Lead-acid Battery - B - SUA48RMXLBP3U
In stock · Ships same business day$2,055.00 $1,394.99 Save $660.01 -
APC by Schneider Electric
SKU: SUA039
APC Smart-ups XL Battery Pack Extension Cable for SUA48 Series Battery Packs - SUA039
In stock · Ships same business day$155.00 $154.99 Save $0.01 -
APC by Schneider Electric
SKU: SUA48XLBP
APC Smart-ups XL Battery Pack Tower/rack Convertible 48V Rackmount with KIT 5U - SUA48XLBP
In stock · Ships same business day$1,660.00 $1,131.99 Save $528.01 -
APC by Schneider Electric
SKU: SUM48RMXLBP2U
APC Smart-ups XL Modular 48V Extended RUN Battery Pack - SUM48RMXLBP2U
In stock · Ships same business day$2,035.00 $1,373.99 Save $661.01 -
APC by Schneider Electric
SKU: XU1K3LLXXRCC
APC Smartups Industrial 1300VA / 1300W 120VAC In/out RM Conformal Coated - XU1K3LLXXRCC
In stock · Ships same business day$3,539.18 $2,370.99 Save $1,168.19 -
APC by Schneider Electric
SKU: XU2K0LLXXRCC
APC Smartups Industrial 2000VA / 1800W 120VAC In/out RM Conformal Coated - XU2K0LLXXRCC
In stock · Ships same business day$7,965.00 $5,300.99 Save $2,664.01 -
APC by Schneider Electric
SKU: AP9625
APC Smartups/smartups RT 2 Post Rail Kits - AP9625
In stock · Ships same business day$412.00 $275.99 Save $136.01 -
APC by Schneider Electric
SKU: SRYL10K20RMXLT
APC SRYL10K20RMXLT Smart-ups Modular Ultra On-line 10KW 9U Rackmount Scalable
In stock · Ships same business day$45,960.00 $29,741.99 Save $16,218.01
UPS & Power Management
Uninterruptible power supplies and rack-mount power distribution for network and surveillance infrastructure. Online and line-interactive UPS models with SNMP management protect against outages and power quality issues.
Plan Your Deployment
- Calculate total VA/watt load from all connected networking and recording equipment
- Specify required battery runtime for graceful shutdown or ride-through
- Evaluate online vs. line-interactive topology for power quality needs
- Confirm rack-mount form factor and outlet count for your cabinet
UPS & Power Management — Engineering-Grade UPS & Power Management for Commercial Deployments
This category covers 4 working models of ups & power management sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.
What to Look For
UPS topology dictates power quality during normal operation and transfer behavior during failure. Standby (offline) units switch to battery on AC failure — cheapest, with brief transfer time acceptable for cameras and switches. Line-interactive units regulate voltage and absorb sags without going to battery, extending battery life. Double-conversion online UPS deliver clean, constantly-regenerated AC — required for sensitive analytical equipment and ideal for critical NVRs.
Runtime is a function of load (watts) and battery capacity (Wh). A 1000VA UPS at 500W load runs 5-8 minutes on internal batteries — enough for graceful shutdown but not extended operation. Extended battery packs add hours. Calculate actual runtime requirement based on average utility outage duration in your area and the device's recovery behavior on power restoration.
Form factor and outlet count drive rack-vs-tower choice and circuit-breaker sizing. Tower UPSs serve standalone NVRs or desktop workstations. 1U-4U rack UPSs serve data closets and rack-mounted equipment. Look at the input plug type (NEMA 5-15, L5-30, L6-30) and confirm the building circuit supports the UPS rating; over-large UPSs on under-sized circuits trip breakers during charging.
Network management cards (APC AP9640, Eaton X-Slot) provide SNMP monitoring, email alerts, and integration with VMS or facility management software. For critical sites, this is essential — silent UPS failure leaves you blind until the next outage exposes it. Schedule annual self-tests through the management interface and replace batteries every 3-5 years as a preventive measure.
Key Specs in This Category
| Spec | Available Options |
|---|---|
| IP Rating | IP20 |
| Connectivity | Wired |
| Power | AC/DC, PoE |
| Type | Power Supply |
Top Brands in This Category
Frequently Asked Questions
What size UPS do I need for an 8-camera NVR?
For an 8-camera NVR drawing about 100-150W and a small PoE switch at 200W, plan for a 1000-1500VA UPS to support 15-30 minutes of runtime. That covers most utility outages and gives ample time for graceful shutdown if power doesn't return. For sites with frequent or extended outages, scale to 2000VA+ with an extended battery pack.
How long does a UPS battery last?
Sealed lead-acid (SLA) UPS batteries typically last 3-5 years. Lithium-ion UPS batteries (newer, more expensive) last 8-10 years. Heat is the primary aging factor — UPSs in unconditioned closets fail batteries faster. Schedule replacement at year 3 for SLA and year 7 for lithium, regardless of self-test results; runtime degrades silently and slowly before complete failure.
Should I use a UPS or a generator for backup power?
UPSs cover seconds-to-minutes outages and bridge to generator startup. Generators cover hours-to-days outages but take 10-30 seconds to come online. For sites that need uninterrupted operation through extended outages, both are required: UPS bridges the generator startup gap and conditions generator power, generator covers the long tail. Standalone UPS without generator works for most commercial sites where occasional brief outages are acceptable.
Can one UPS power my entire camera system?
For small sites (8-16 cameras, single NVR, one switch) — yes, a single UPS works. For larger sites, distribute UPS protection across multiple smaller units rather than one large UPS. Reasons: failure isolation (one UPS battery failure doesn't take down everything), shorter cable runs from UPS to load (avoids voltage drop), and runtime calculation simplicity per zone.
What's the difference between line-interactive and online UPS?
Line-interactive UPSs run on utility power normally and switch to battery on failure. They include voltage regulation (AVR) that absorbs sags and surges without battery use. Online (double-conversion) UPSs continuously regenerate AC from battery-rectified DC — perfect output regardless of input quality. Online UPSs cost 2-3x more and are appropriate for highly sensitive loads (servers, lab equipment) or sites with very poor utility power.
Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.