Overview

SKU: APDU10450SW
UPC: 731304439110
Condition: New
Write a Review 33% OFF

APC Netshelter Rack PDU Advanced Switched 34.6KW 3PH 415V 60A 560P6 42 OU - APDU10450SW

APC by Schneider Electric APDU10450SW Advanced Switched 3-Phase Rack PDUOverviewThe APDU10450SW is a high-density, switched 3-phase rack PDU rated for…

$7,525.00 $5,008.99 SAVE $2516
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC Netshelter Rack PDU Advanced Switched 34.6KW 3PH 415V 60A 560P6 42 OU - APDU10450SW

$7,525.00
$5,008.99

Overview

SKU: APDU10450SW
UPC: 731304439110
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric APDU10450SW Advanced Switched 3-Phase Rack PDU

Overview

The APDU10450SW is a high-density, switched 3-phase rack PDU rated for 34.6kW at 415V/60A — engineered for data centers, network operations centers, and enterprise server rooms where remote outlet control and real-time power visibility are non-negotiable. It delivers up to 48 individually switchable AC outlets across a mix of IEC C13, C15, C19, and C21 receptacle types, so you can manage equipment of varying draw from a single vertically mounted unit. The IEC 60309 560P6 input plug means it connects directly to the 3-phase branch circuits common in European and international data center builds without field-wiring adapters.

The LCD display gives local technicians immediate access to power readings without opening a remote session, while daisy-chain capability lets you link multiple PDUs to a single network port — keeping switch port consumption in check as your cabinet density grows.

Key Features

  • 34.6kW / 60A Capacity: At 200–240V nominal input with a 60A maximum current draw, the APDU10450SW supports fully loaded high-density cabinets running GPU servers, blade chassis, or storage arrays. That headroom matters when a single rack can pull 20–30kW in modern AI/compute deployments.
  • 48 Switched AC Outlets: Individual outlet switching means you can remotely cycle a hung server, reboot a misbehaving switch, or gracefully sequence power-on order — without dispatching a technician to the data hall. At 48 outlets per PDU, one unit can serve an entire densely populated 42U cabinet.
  • Mixed Outlet Types (C13, C15, C19, C21): The four IEC coupler types accommodate standard 1U/2U servers (C13/C15), high-draw devices like UPS bypass switches and PDU distribution panels (C19), and C21 outlets rated for higher temperatures — eliminating the need for in-line adapters that introduce connection-point failure risk.
  • IEC 60309 560P6 Input Plug: The 560P6 (5-pin, 60A, 3-phase) is a keyed, twist-lock connector used throughout European and international data centers and colocation facilities. It connects directly to standard 3-phase branch circuit outlets without a field-modified pigtail.
  • LCD Local Display: The integrated LCD provides on-cabinet current, voltage, and power readings. During maintenance windows — when remote access may be restricted — local metering lets technicians verify load before switching circuits without guessing.
  • Daisy Chain Support: Linking multiple APDU10450SW units through a single network management connection keeps IP address allocation and switch port counts lean. In a multi-PDU-per-cabinet design, this directly reduces both network infrastructure spend and management complexity.
  • Vertical 0U Mounting: The vertical zero-U form factor mounts in the side channel of standard 600mm or 800mm wide racks, preserving all 42U of usable rack space for revenue-generating equipment. No rack units sacrificed to power distribution.
  • 50–60 Hz Input Frequency: Dual-frequency compatibility means this unit deploys in both 50 Hz (European/Asian grid) and 60 Hz (North American grid) facilities — useful for organizations with globally distributed data centers standardizing on a single PDU SKU.
  • Black Finish: Standard data center black integrates cleanly into mixed-vendor cabinet environments without requiring color-coordinated cable management.

Integration and Compatibility

The APDU10450SW operates at 200–240V nominal input and 240V nominal output, aligning with international 3-phase branch circuit standards. The 60A maximum input current per phase sets the upstream breaker sizing requirement — plan for a dedicated 60A 3-phase circuit with appropriate feeder conductor sizing per local electrical code. Daisy chain functionality reduces the per-PDU network port requirement, which is particularly valuable in high-density deployments where network switch ports in the row are limited. The APDU10450SW is suited for integration with APC's power management ecosystem and enterprise DCIM platforms that support SNMP-based PDU polling. For larger data center buildouts, evaluate pairing with compatible managed network switches to support out-of-band management connectivity to the PDU network port. When planning cabinet power, also review your UPS infrastructure to confirm upstream runtime and bypass capacity matches the PDU's full 34.6kW load envelope. Buyers specifying this unit for international colo deployments should confirm local authority having jurisdiction (AHJ) requirements for 560P6 termination and 3-phase branch circuit protection.

Frequently Asked Questions

Q: What input plug does the APDU10450SW use?

A: The APDU10450SW uses an IEC 60309 560P6 plug — a 5-pin, 60A, 3-phase twist-lock connector standard in European and international data center and colocation facilities.

Q: How many outlets does the APDU10450SW provide, and what types?

A: It provides 48 AC outlets across four IEC coupler types: C13, C15, C19, and C21 — accommodating standard servers, high-draw devices, and high-temperature-rated loads on a single PDU.

Q: Can I manage multiple APDU10450SW units from a single network connection?

A: Yes. The APDU10450SW supports daisy chaining, allowing multiple units to share a single network management port — reducing the number of switch ports and IP addresses required per cabinet.

Q: What is the maximum power capacity of the APDU10450SW?

A: The APDU10450SW is rated for 34,600 VA (34.6kW) at 415V, 3-phase, 60A maximum input current per phase.

Q: Does the APDU10450SW have a local display?

A: Yes. An integrated LCD display provides local power metering — useful when remote access is unavailable or restricted during maintenance windows.

Q: Is the APDU10450SW a metered or switched PDU?

A: It is a switched PDU, meaning each of the 48 outlets can be individually powered on or off remotely — enabling remote server reboots, load sequencing, and circuit isolation without a physical site visit.

James Everett
James Everett

When I look at the APDU10450SW, the spec that stands out immediately is the 48-outlet count combined with switched control at 34.6kW — that is a serious density-and-control combination. Most enterprise deployments I see run into one of two problems: not enough receptacles per cabinet, or not enough remote control granularity. This unit solves both simultaneously, which is why it belongs in high-density compute and storage rows rather than general IT closets.

Technical Highlights:

  • 60A / 34.6kW Capacity: At 60A per phase on a 3-phase feed, this PDU can sustain a fully loaded GPU-dense or blade-heavy cabinet without tripping branch breakers under transient load spikes — the 34.6kW ceiling gives genuine headroom for modern AI/HPC rack profiles.
  • 48 Switched Outlets: Individual remote switching on all 48 outlets means helpdesk staff can execute a hard reboot on a hung node without involving data center hands — meaningful in large colocation deployments where an on-site visit costs real money and time.
  • Mixed C13/C15/C19/C21 Receptacle Types: The four coupler types on a single PDU eliminate the adapter chains that introduce connection-point failure risk in high-uptime environments — every device plugs native.

Deployment Considerations:

  • The IEC 60309 560P6 input plug is standard in European and international colo facilities — verify your branch circuit termination matches before ordering; retrofitting a US NEMA feed to this plug in the field is a licensed-electrician job, not a quick swap.
  • At 60A input per phase, upstream breaker and feeder conductor sizing must be confirmed against local electrical code before installation — do not assume an existing 32A or 40A 3-phase circuit can feed this unit at rated load.

The APDU10450SW is the right specification for international colocation cabinets running high-density compute workloads — specifically rows where remote outlet cycling, mixed IEC load types, and 34kW+ cabinet envelopes all need to be managed from a single vertically mounted unit without burning switch ports on per-PDU network connections.

Specifications
PDU types: Switched
Type: Single-phase
Rack capacity: 0U
Mounting: Vertical
Product colour: Black
Display: LCD
On/off switch: No
AC outlets quantity: 48 AC outlet(s)
Power plug: IEC 60309
AC outlet types: C13 coupler, C15 coupler, C19 coupler, C21 coupler
Daisy chain: Yes
Nominal input voltage: 200 - 240 V
AC input frequency: 50 - 60 Hz
Maximum current: 60 A
Nominal output voltage: 240 V
Output voltage: 240 V
Load capacity: 34600 VA
Maximum input current per phase: 60 A
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources