APC by Schneider Electric
SKU: APDU11350SM
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APDU10450SW is a high-density, switched 3-phase rack PDU rated for 34.6kW at 415V/60A — engineered for data centers, network operations centers, and enterprise server rooms where remote outlet control and real-time power visibility are non-negotiable. It delivers up to 48 individually switchable AC outlets across a mix of IEC C13, C15, C19, and C21 receptacle types, so you can manage equipment of varying draw from a single vertically mounted unit. The IEC 60309 560P6 input plug means it connects directly to the 3-phase branch circuits common in European and international data center builds without field-wiring adapters.
The LCD display gives local technicians immediate access to power readings without opening a remote session, while daisy-chain capability lets you link multiple PDUs to a single network port — keeping switch port consumption in check as your cabinet density grows.
The APDU10450SW operates at 200–240V nominal input and 240V nominal output, aligning with international 3-phase branch circuit standards. The 60A maximum input current per phase sets the upstream breaker sizing requirement — plan for a dedicated 60A 3-phase circuit with appropriate feeder conductor sizing per local electrical code. Daisy chain functionality reduces the per-PDU network port requirement, which is particularly valuable in high-density deployments where network switch ports in the row are limited. The APDU10450SW is suited for integration with APC's power management ecosystem and enterprise DCIM platforms that support SNMP-based PDU polling. For larger data center buildouts, evaluate pairing with compatible managed network switches to support out-of-band management connectivity to the PDU network port. When planning cabinet power, also review your UPS infrastructure to confirm upstream runtime and bypass capacity matches the PDU's full 34.6kW load envelope. Buyers specifying this unit for international colo deployments should confirm local authority having jurisdiction (AHJ) requirements for 560P6 termination and 3-phase branch circuit protection.
Q: What input plug does the APDU10450SW use?
A: The APDU10450SW uses an IEC 60309 560P6 plug — a 5-pin, 60A, 3-phase twist-lock connector standard in European and international data center and colocation facilities.
Q: How many outlets does the APDU10450SW provide, and what types?
A: It provides 48 AC outlets across four IEC coupler types: C13, C15, C19, and C21 — accommodating standard servers, high-draw devices, and high-temperature-rated loads on a single PDU.
Q: Can I manage multiple APDU10450SW units from a single network connection?
A: Yes. The APDU10450SW supports daisy chaining, allowing multiple units to share a single network management port — reducing the number of switch ports and IP addresses required per cabinet.
Q: What is the maximum power capacity of the APDU10450SW?
A: The APDU10450SW is rated for 34,600 VA (34.6kW) at 415V, 3-phase, 60A maximum input current per phase.
Q: Does the APDU10450SW have a local display?
A: Yes. An integrated LCD display provides local power metering — useful when remote access is unavailable or restricted during maintenance windows.
Q: Is the APDU10450SW a metered or switched PDU?
A: It is a switched PDU, meaning each of the 48 outlets can be individually powered on or off remotely — enabling remote server reboots, load sequencing, and circuit isolation without a physical site visit.

When I look at the APDU10450SW, the spec that stands out immediately is the 48-outlet count combined with switched control at 34.6kW — that is a serious density-and-control combination. Most enterprise deployments I see run into one of two problems: not enough receptacles per cabinet, or not enough remote control granularity. This unit solves both simultaneously, which is why it belongs in high-density compute and storage rows rather than general IT closets.
Technical Highlights:
Deployment Considerations:
The APDU10450SW is the right specification for international colocation cabinets running high-density compute workloads — specifically rows where remote outlet cycling, mixed IEC load types, and 34kW+ cabinet envelopes all need to be managed from a single vertically mounted unit without burning switch ports on per-PDU network connections.