APC by Schneider Electric
SKU: APDU10452SW
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APDU11452SW is APC's high-density, switched 3-phase rack PDU targeting data centers, colocation environments, and large-scale surveillance or IT infrastructure deployments where individual outlet-level power control and precision metering are non-negotiable. Running on 208V 3-phase at up to 60A and delivering 17,300 VA of load capacity, this unit supports the kind of dense compute and storage racks that would overwhelm a single-phase PDU or a basic metered model. If you're provisioning power for a multi-rack security operations center, a server room, or a high-density NVR/storage array environment, the APDU11452SW is sized for the job. Explore the full APC by Schneider Electric power management catalog for complementary UPS and power distribution options.
The APDU11452SW integrates with APC's EcoStruxure IT and Data Center Expert (DCE) platforms via SNMP, enabling centralized monitoring and automated alerting alongside UPS, environmental sensors, and other networked infrastructure. The NPS architecture allows the unit to share network access with up to 31 peer PDUs — useful when IP management overhead is a constraint in large deployments. For UPS and power distribution planning, pairing this PDU downstream of an appropriately sized 3-phase UPS (sized to match the 17.3kW draw at target utilization) is the standard architecture for protected, switched power at this capacity tier.
Q: What input plug does the APDU11452SW use?
A: The APDU11452SW uses an IEC 60309 60A 3-phase + protective earth (3P+PE) input plug on a 10 ft. (3 m) cord. This is a commercial/industrial connector standard — confirm your facility's power panel provides a matching 60A 3-phase receptacle before installation.
Q: How many outlets does the APDU11452SW provide, and what types?
A: The unit provides 42 output connections supporting IEC C13, C15, C19, and C21 receptacle types. This mixed outlet configuration accommodates standard servers (C13), hot-environment equipment (C15), high-draw devices (C19), and specialty hardware (C21) within a single PDU.
Q: What is the metering accuracy on the APDU11452SW?
A: The APDU11452SW provides ±1% metering accuracy — tighter than the ±2% specification common on entry-level managed PDUs. This matters for capacity planning when you need to accurately determine how close you are to a circuit's 80% continuous utilization threshold.
Q: How does Network Port Sharing work on the APDU11452SW?
A: The APDU11452SW includes one 10/100/1000 Ethernet port plus two NPS link ports. Using APC's NPS daisy-chain architecture, up to 32 PDUs can share a single network IP address. Each PDU remains individually addressable for monitoring and control, but only one network connection and one IP are required for the entire chain.
Q: What is the maximum load capacity of the APDU11452SW?
A: The APDU11452SW supports a maximum load of 17,300 VA (17.3kW) at 208V 3-phase, 60A input. Per standard electrical practice, design your connected load to no more than 80% of this figure — approximately 13,840 VA — for continuous safe operation.
Q: What is the operating temperature range for the APDU11452SW?
A: The APDU11452SW is rated for operating temperatures up to 60°C (140°F), making it suitable for hot-aisle deployments and enclosed cabinet environments where ambient temperatures may be elevated.

The APDU11452SW is the right PDU for any 3-phase 208V rack deployment where outlet-level remote switching is a hard requirement — not just a nice-to-have. The 17,300 VA / 60A input capacity positions this unit squarely for high-density racks: think multi-NVR storage arrays, hyperconverged infrastructure nodes, or GPU-based video analytics appliances where a single chassis can pull 3–5kW at load.
Technical Highlights:
Deployment Considerations:
For a high-density security operations center running 20+ NVRs and analytics servers in a purpose-built 3-phase power room, the APDU11452SW delivers the switching control and measurement precision that metered-only PDUs cannot — and the NPS architecture keeps IP management sane as the deployment scales.