APC by Schneider Electric
SKU: APDU11451SW
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APDU10451SW is a 14.4kW, 3-phase, 208V Advanced Switched rack PDU from APC by Schneider Electric built for high-density data center and server room environments where per-outlet remote switching is a hard operational requirement — not a nice-to-have. At 50A input via a CS8365C plug and 14,400 VA total load capacity, this unit is sized for fully loaded 42U cabinets running dense compute, storage, or network infrastructure. The 71.89-inch (182.6 cm) form factor fits standard 0U vertical mounting channels inside a NetShelter or comparable deep rack enclosure, keeping PDU bulk out of horizontal U-space. If you're managing high-density switching or server infrastructure where unplanned downtime is expensive, the remote switching capability on this unit is what separates it from a basic metered PDU.
The APDU10451SW is designed for integration within NetShelter rack systems and compatible 0U-channel enclosures from other manufacturers. The Advanced Switched PDU line provides network-accessible outlet control — verify network management card compatibility and firmware revision requirements for your APC EcoStruxure IT or Data Center Expert management infrastructure before deployment. For environments already running APC infrastructure management, this PDU integrates into the same management plane as other Advanced series units. Pair this with an appropriately rated UPS upstream — a 14.4kW load requires a UPS sized well above that figure (account for efficiency losses and N+1 headroom). The 50/60 Hz dual-frequency support means a single SKU can be stocked across North American and international facilities without maintaining separate part numbers for each region.
Q: What input plug does the APDU10451SW use?
A: The APDU10451SW uses a CS8365C locking plug — a 4-wire (3P+G), 50A, 3-phase connector standard in North American data center power distribution. Your facility panel or in-row PDU must have a matching CS8365R receptacle.
Q: What is the total power capacity of the APDU10451SW?
A: The APDU10451SW is rated at 14,400 VA (14.4kW) at 208V, 3-phase, 50A input. Plan your per-phase load distribution across A, B, and C legs to stay within breaker limits.
Q: Will the APDU10451SW work in a 50 Hz facility outside North America?
A: Yes — the APDU10451SW supports both 50 Hz and 60 Hz input frequency, making it compatible with North American 60 Hz facilities and international installations running 50 Hz power grids, provided the 208V 3-phase input voltage matches your distribution infrastructure.
Q: Does the APDU10451SW fit in a standard 42U rack?
A: The unit measures 71.89 inches (182.6 cm) and is designed for 0U vertical mounting in standard 42U rack enclosures. Verify the internal vertical PDU channel dimensions of your specific cabinet — racks with installed cable management arms may have reduced clearance.
Q: How heavy is the APDU10451SW and can one person install it?
A: The unit weighs 24.7 lb (11.2 kg). While the weight is manageable for one person, the 71-inch length makes two-person installation strongly advisable to avoid damage during racking in confined hot-aisle/cold-aisle layouts.
Q: What is the cord length on the APDU10451SW?
A: The input power cord is 5.9 ft (1.8 m). Measure the distance from your PDU vertical mount position to the facility power tap before installation — tight or non-standard cabinet configurations may require repositioning the tap point.

The APDU10451SW sits at the intersection of capacity and control — 14,400 VA at 208V 3-phase is genuinely high-density territory, and the Advanced Switched designation means you're getting per-outlet remote power cycling rather than just monitoring. For any environment where a hung server or locked-up network appliance requires a physical site visit to reboot, that switching capability directly translates to reduced MTTR and lower operational cost per incident.
Technical Highlights:
Deployment Considerations:
The APDU10451SW is the right spec for a greenfield high-density data center row where 208V 3-phase distribution is already provisioned and the operations team needs remote outlet control to avoid truck-roll costs on routine server reboots — co-location facilities and enterprise server rooms with geographically distributed IT staff are the primary deployment target.