Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric APDU11450SW Advanced Switched 3-Phase Rack PDU

Overview

The APC by Schneider Electric APDU11450SW is a high-density, advanced switched rack PDU engineered for 3-phase power distribution in demanding data center and enterprise rack environments. Rated at 34.6KW at 415V with a 60A input on a 560P6 plug, this unit delivers granular per-outlet switching and monitoring across 21 output connectors — giving facilities and IT teams the control they need to manage power loads, sequence equipment startup, and respond to remote reboot requests without dispatching staff to the floor. For environments running network video recorders, edge compute nodes, or high-density IP camera infrastructure, consolidated switched PDU management translates directly into reduced downtime and faster incident response.

Key Features

  • 34.6KW / 415V / 60A 3-Phase Input: Handles serious rack power loads — enough headroom for fully populated high-density compute or storage racks without requiring multiple PDUs per rack. The 560P6 plug mates with standard 3-phase facility circuits common in Tier III/IV data centers.
  • Advanced Switched Per-Outlet Control: Each outlet can be switched on, off, or rebooted independently via the network interface. This matters in production environments where a hung NVR or managed switch needs a controlled power cycle without touching other rack residents.
  • 21 Output Connectors (C13/C15/C19/C21 Mix): The mixed outlet format accommodates both standard IEC C14 devices and higher-current C20 equipment on the same PDU — useful in mixed-density racks that combine 1U servers, storage arrays, and power-hungry GPU nodes.
  • 240V Output Voltage: Downstream devices receive 240V, compatible with international and dual-voltage enterprise hardware — a practical consideration in globally standardized rack deployments.
  • 0U Vertical Form Factor (71.9" H × 3" W × 2.2" D): Mounts vertically inside the rack cabinet without consuming rack unit space. The 2.2-inch depth keeps it flush against the side rail, preserving airflow paths and cable management lanes critical in high-density thermal environments.
  • NetShelter Series Integration: Designed within the APC NetShelter ecosystem, this PDU pairs cleanly with NetShelter SX and SY enclosures, simplifying procurement and support for shops already standardized on APC by Schneider Electric infrastructure.
  • Remote Management Capable: The "Advanced Switched" designation signals built-in network management — enabling outlet-level scheduling, load monitoring, and environmental alerting through APC's management interface. This is the feature that separates it from metered-only or basic switched models in the rack PDU category.

Integration & Compatibility

The APDU11450SW is suited for integration into data center infrastructure management (DCIM) platforms and pairs with APC's EcoStruxure IT software for centralized power monitoring. Its 3-phase design requires a compatible 60A 415V facility circuit and 560P6 receptacle — verify with your facilities team before ordering. For multi-rack deployments, consider pairing with a UPS upstream to provide runtime and protection against input power events. Refer to your rack power planning guide for load balancing across phases before commissioning.

Frequently Asked Questions

Q: What input plug type does the APDU11450SW use?

A: The APDU11450SW uses a 560P6 plug, designed for 3-phase 60A 415V facility circuits standard in enterprise data center environments.

Q: How many outlets does the APDU11450SW provide?

A: It provides 21 output connectors in a mixed C13/C15/C19/C21 configuration, accommodating a range of IEC-standard enterprise hardware.

Q: Does the APDU11450SW take up rack unit space?

A: No — at 71.9 inches tall, 3 inches wide, and 2.2 inches deep, it mounts vertically inside the rack cabinet in a 0U configuration, preserving rack unit space for active equipment.

Q: What is the output voltage of the APDU11450SW?

A: The output voltage is 240V, suitable for dual-voltage and international enterprise hardware commonly deployed in mixed data center environments.

Q: Can individual outlets be controlled remotely on the APDU11450SW?

A: Yes. As an Advanced Switched PDU, the APDU11450SW supports per-outlet remote switching — including individual power cycling — via its network management interface.

Karl Wilson
Karl Wilson

The APDU11450SW is one of the heavier hitters in APC's switched PDU lineup — a 34.6KW, 60A, 3-phase unit that makes sense when you're powering a full high-density rack and need outlet-level control over every device in it. I reach for this model when a customer is running mixed compute and storage in a colocation or enterprise machine room and needs the ability to remotely cycle specific devices without affecting adjacent rack residents.

Technical Highlights:

  • 34.6KW at 415V / 60A: That's enough load capacity for a densely populated rack — think dual-socket servers, NVMe storage shelves, and network gear simultaneously — without splitting the load across two PDUs and two circuit drops.
  • 21 Mixed IEC Outlets (C13/C15/C19/C21): The outlet mix handles both standard and high-current loads in the same chassis. You're not forced to homogenize your hardware selection around a single plug type, which matters in mixed-vendor environments.
  • 0U Vertical Mounting (71.9" × 3" × 2.2"): At 2.2 inches of depth, this sits nearly flush against the rail. In hot-aisle/cold-aisle containment setups, that depth discipline matters — every inch of PDU protrusion is airflow you're fighting.

Deployment Considerations:

  • Confirm your facility has a 560P6 60A 3-phase receptacle before finalizing the order — retrofitting a circuit for this input spec is a facilities project, not a day-of task.
  • The 240V output is correct for dual-voltage enterprise hardware but will not serve single-phase 120V North American devices — plan your outlet allocation accordingly if the rack has mixed-voltage requirements.

This PDU is the right call for a Tier III or Tier IV data center rack running compute-intensive workloads — video analytics servers, GPU inference nodes, or high-channel NVR infrastructure — where remote outlet control and 3-phase load distribution are non-negotiable operational requirements.

Specifications
Series: NetShelter Rack
Model: APDU11450SW
Type: PDUs & Line Conditioners
Output Voltage: 240 V
Output Connector(S: 21 C13/C15/C19/C21 21C13/C15
Dimensions: Width: 71.9 InchDepth: 2.2 InchHeight: 3 Inch
Sold By: IT Devices Online
Save: 9%
Q&A
Reviews
Have Questions?

APC Netshelter Rack PDU Advanced Switched 34.6KW 3PH 415V 60A 560P6 42 OU - APDU11450SW

$7,705.00
$5,219.99

RELATED PRODUCTS

Save $2,516.01
APC Netshelter Rack PDU Advanced Switched 34.6KW 3PH 415V 60A 560P6 42 OU - APDU
Add to Cart The item has been added

APC by Schneider Electric APDU10450SW

APC Netshelter Rack PDU Advanced Switched 34.6KW 3PH 415V 60A 560P6 42 OU - APDU10450SW

High-density, switched 3-phase rack PDU rated for 34.6kW at 415V/60A — engineered for data centers, network operations centers, and enterprise server

    Usually Ships in 2-3 Weeks Free shipping over $499
    $7,525.00 $5,008.99 Save $2,516.01
    The item has been added Add to quote
    $7,525.00 $5,008.99 Save $2,516.01
    Save $2,516.01 Add to cart Add to quote
    Save $1,893.01
    APC Netshelter Rack PDU Advanced Metered 34.6KW 3PH 415V 60A 560P6 42 OUT - APDU
    Add to Cart The item has been added

    APC by Schneider Electric APDU11450ME

    APC Netshelter Rack PDU Advanced Metered 34.6KW 3PH 415V 60A 560P6 42 OUT - APDU11450ME

    High-density, 3-phase advanced metered rack PDU engineered for data centers and enterprise server rooms where granular power visibility and

      In stock · Ships same business day Free shipping over $499
      $5,870.00 $3,976.99 Save $1,893.01
      The item has been added Add to quote
      $5,870.00 $3,976.99 Save $1,893.01
      Save $1,893.01 Add to cart Add to quote
      Save $3,106.01
      APC Netshelter Rack PDU Advanced Switched Metered Outlet 34.6KW 3PH 415V 60 - AP
      Add to Cart The item has been added

      APC by Schneider Electric APDU11450SM

      APC Netshelter Rack PDU Advanced Switched Metered Outlet 34.6KW 3PH 415V 60 - APDU11450SM

      PC's high-density, three-phase advanced switched metered outlet PDU built for enterprise data centers and large network equipment rooms where 34.6kW

        Usually Ships in 2-3 Weeks Free shipping over $499
        $9,290.00 $6,183.99 Save $3,106.01
        The item has been added Add to quote
        $9,290.00 $6,183.99 Save $3,106.01
        Save $3,106.01 Add to cart Add to quote
        Save $1,391.01
        APC Netshelter Rack PDU Advanced Switched 11.5KW 3PH 415V 20A 520P6 42 OU - APDU
        Add to Cart The item has been added

        APC by Schneider Electric APDU11250SW

        APC Netshelter Rack PDU Advanced Switched 11.5KW 3PH 415V 20A 520P6 42 OU - APDU11250SW

        High-density, 3-phase switched rack power distribution unit engineered for data centers and enterprise server rooms that demand per-outlet power

          Usually Ships in 2-3 Weeks Free shipping over $499
          $4,155.00 $2,763.99 Save $1,391.01
          The item has been added Add to quote
          $4,155.00 $2,763.99 Save $1,391.01
          Save $1,391.01 Add to cart Add to quote
          Save $1,317.01
          APC Netshelter Rack PDU Advanced Switched 11.5KW 3PH 415V 20A 520P6 42 OU - APDU
          Add to Cart The item has been added

          APC by Schneider Electric APDU10250SW

          APC Netshelter Rack PDU Advanced Switched 11.5KW 3PH 415V 20A 520P6 42 OU - APDU10250SW

          N 11.5KW, 3-phase, 415V switched rack PDU built for high-density data center and server room deployments where per-outlet power control is not

            Usually Ships in 2-3 Weeks Free shipping over $499
            $4,055.00 $2,737.99 Save $1,317.01
            The item has been added Add to quote
            $4,055.00 $2,737.99 Save $1,317.01
            Save $1,317.01 Add to cart Add to quote

            System Design, Deployment & Technical Support

            Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

            Fixed scope • Fixed price

            System Design Assistance

            • Get help validating product compatibility
            • Coverage requirements
            • Storage planning and deployment architecture before you buy.
            Request Design Help

            Deployment & Configuration Support

            • Access fixed-scope support for rollout planning
            • User setup guidance
            • Migration and system standardization across single-site or multi-site deployments
            View Support Services

            Guides, Tools & Calculators

            • PoE requirements
            • Storage retention
            • Camera selection and deployment methodology
            Open Technical Resources