Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: CJSUDCAPBU-X
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 45% OFF

Panduit CJSUDCAPBU-X Cat 6A Shielded TG Wire Cap - Blue

Panduit CJSUDCAPBU-X 45° Angled Wire Cap for Cat 6A Shielded TG Jack The Panduit CJSUDCAPBU-X is a 45° angled wire cap engineered specifically for Cat…

$100.37 $54.99 SAVE $45

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit CJSUDCAPBU-X Cat 6A Shielded TG Wire Cap - Blue

$100.37
$54.99

Overview

SKU: CJSUDCAPBU-X
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit CJSUDCAPBU-X 45° Angled Wire Cap for Cat 6A Shielded TG Jack

The Panduit CJSUDCAPBU-X is a 45° angled wire cap engineered specifically for Cat 6A shielded TG jack installations where horizontal cable routing and EMI protection continuity are critical. Part of the Pan-Net® modular jack system, this blue wire cap provides both mechanical strain relief and visual identification compliance with TIA-606-B color standards. The angled design routes cable bundles parallel to the mounting surface—essential in high-density patch panels, zone distribution boxes, and surface-mount applications where vertical cable stubs would create clearance conflicts or compromise bend-radius limits. Each 10-piece package supports installations ranging from single-rack deployments to mid-size floor buildouts, while the 100-piece carton quantity addresses datacenter-scale projects requiring consistent shielded termination aesthetics and performance across hundreds of ports.

Key Features

  • 45° angled wire path optimized for horizontal cable routing in patch panels and surface-mount jacks
  • Maintains 360° shield continuity at jack termination point, preserving Cat 6A shielded channel integrity for EMI/RFI rejection
  • Blue housing for TIA-606-B Cat 6/6A identification compliance in multi-category installations
  • Injection-molded strain relief clamps cable jacket without crushing conductor pairs or compromising pair geometry
  • Pan-Net® system component engineered for mechanical and electrical compatibility with Panduit Cat 6A shielded TG jacks
  • 10-piece package quantity supports typical rack or zone deployments; 100-piece carton available for large-scale projects

Shielded twisted pair installations require unbroken shield continuity from patch panel to wall plate to maintain the EMI rejection performance that justifies the cost premium over UTP. The CJSUDCAPBU-X wire cap completes the shield path by providing a conductive interface between the cable's foil shield and the TG jack's die-cast shield housing. Unlike aftermarket or universal caps that may introduce impedance discontinuities or shield gaps, this Panduit-engineered component is dimensioned to maintain the 100-ohm impedance target across the termination point while providing the mechanical clamping force required for reliable shield contact under thermal cycling and vibration. The 45° angle is not merely cosmetic—it reduces the effective bend radius where cable exits the jack, which is critical in shallow wall boxes or back-to-back patch panel installations where a 90° stub would force cable into a radius tighter than the 4× cable diameter minimum specified in TIA-568.2-D. In horizontal applications such as under-desk zone boxes or raceway-mounted jacks, the angled cap routes the cable parallel to the mounting surface, eliminating the need for secondary bend-radius management and reducing the depth of the finished assembly by approximately 1.2 inches compared to straight-exit caps.

Typical deployment scenarios include datacenter top-of-rack patching where 48-port panels require consistent cable routing to overhead cable tray, healthcare nurse-call integration where shielded Cat 6A carries both data and low-voltage control signals in high-EMI environments, and industrial automation networks where VFD noise and motor controllers demand shielded channels for reliable PLC and HMI communication. The blue color serves dual purposes: compliance with TIA-606-B Annex A color-coding (blue designates horizontal Cat 6/6A cabling in most enterprise standards), and visual differentiation from legacy Cat 5e ports during mixed-generation retrofits. The 10-piece package aligns with single-rack deployments (a 42U rack with dual 24-port panels) or small office installations, while contractors running multi-floor datacenter builds typically order the 100-piece carton to maintain consistent stock across crews and ensure color/batch consistency. The cap installs tool-free after cable termination—slide over the cable jacket, seat the jack into the panel or wall plate, then snap the cap onto the jack body until the locking tabs engage. Removal requires depressing the side tabs; the cap can be reused if the jack is reseated or the cable is re-terminated, though best practice is to discard and replace after any termination rework to ensure the strain-relief boot hasn't fatigued.

As a Pan-Net® system component, the CJSUDCAPBU-X is validated for mechanical fit and electrical performance with Panduit's CJS6X88TG** family of Cat 6A shielded TG jacks. While the cap may physically fit competitive jacks using the TG (reduced-size) form factor, Panduit does not guarantee shield continuity or channel performance unless the complete termination uses Panduit jacks, caps, patch cords, and tested cable. Installations requiring third-party lab certification (UL, ETL) or compliance verification for military, healthcare, or financial industry standards should maintain single-vendor termination hardware to simplify the certification path and eliminate finger-pointing during acceptance testing. The shielded TG jack + angled cap combination is specifically called out in Panduit's application guides for 10GBASE-T over copper and Power over Ethernet (PoE++) deployments where heat dissipation and shield grounding are both performance-critical.

Specifications
Product Type: Wire Cap / Strain Relief Boot
Manufacturer: Panduit
MPN: CJSUDCAPBU-X
Sub-Brand: Pan-Net®
Cable Category: Cat 6A Shielded
Jack Compatibility: Panduit Cat 6A Shielded TG Jacks
Angle: 45° Angled
Color: Blue
Shielding: Shielded (maintains shield continuity)
TIA-606-B Compliance: Yes (Blue = Cat 6/6A horizontal cabling)
Material: Injection-molded plastic with conductive shield contact
Package Quantity: 10 pieces
Carton Quantity: 100 pieces
Installation Method: Tool-free snap-on
UPC: 61305657853
Application: Horizontal cable routing in patch panels, wall plates, zone distribution boxes
Standards Compliance: TIA-568.2-D, TIA-606-B
Type: Wire Cap
Connectivity: Cat 6A
Sub Brand: Pan-Net®
Carton Qty: 100
Package Qty: 10
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources