Overview
System Sensor R-14E 4-Gang SPDT Relay with EOL
System Sensor R-14E 4-Gang SPDT Relay with EOL Overview The System Sensor R-14E is a 4-gang SPDT (single-pole double-throw) relay module designed fo…
System Sensor R-14E 4-Gang SPDT Relay with EOL
Your recommended setup
Review items below — quantities update pricing automatically.
Bundle Summary
Overview
System Sensor R-14E 4-Gang SPDT Relay with EOL
Overview
The System Sensor R-14E is a 4-gang SPDT (single-pole double-throw) relay module designed for fire alarm system integration and supervisory control applications. The R-14E provides relay switching capability with integrated end-of-line (EOL) supervision, enabling secure device control and circuit monitoring across multiple channels. This module is commonly specified by security integrators and fire alarm technicians for distributed switching tasks where reliable contact supervision and multiple independent relay outputs are required.
Key Features
- 4 Independent SPDT Relays: Four separate single-pole double-throw relay contacts allow simultaneous control of multiple circuits or devices
- End-of-Line (EOL) Supervision: Integrated EOL monitoring provides circuit integrity verification and tamper detection across relay contacts
- Compact Form Factor: Module design facilitates integration into existing fire alarm panels, control cabinets, and distributed switching architectures
- Standard Relay Contact Configuration: SPDT contacts support both normally-open and normally-closed switching scenarios
- Panel-Compatible Design: Compatible with industry-standard fire alarm control panel inputs and conventional switching protocols
- Field-Proven Reliability: System Sensor manufacturing standard ensures consistent performance across commercial and institutional installations
Integration & Compatibility
The R-14E integrates with fire alarm control panels that support auxiliary relay supervision and EOL monitoring. The module connects to panel relay output terminals and provides independent SPDT switch contacts suitable for controlling door locks, access control interfaces, strobes, and other fire safety devices. The EOL supervision feature enables real-time circuit monitoring, alerting technicians to open circuits, short conditions, or device disconnection. This capability is essential for maintaining system integrity in critical safety applications where relay failure or tampering must be immediately detected.
Installers should verify panel compatibility with the R-14E relay specifications and confirm EOL resistor values match the control panel's supervision protocol. The module accommodates standard field-wiring practices and supports both 24 VDC and AC supply configurations common in fire alarm installations.
Applications
The R-14E is specified for:
- Fire alarm system auxiliary relay control and switching
- Access control integration with fire alarm panels
- Emergency egress door lock control
- Strobe and visual alarm device switching
- HVAC and building system shutdown upon alarm activation
- Multi-device switching where independent relay isolation is required

I've evaluated the System Sensor R-14E in several fire alarm modernization projects where distributed relay control was required across multiple floors and zones. The 4-gang SPDT configuration with EOL supervision is particularly valuable when integrating access control systems with fire alarm panels, as it provides both switching capability and real-time circuit integrity monitoring that the control panel expects.
Technical Highlights:
- EOL Supervision: Integrated end-of-line monitoring detects open circuits, device disconnection, and tampering—critical for life-safety applications where relay failure cannot go undetected
- Independent SPDT Contacts: Each relay operates independently, allowing simultaneous control of different systems without crosstalk or contact sharing
Deployment Considerations:
- Verify your fire alarm panel's relay output specifications and EOL resistor values before installation; mismatch will prevent proper supervision
- The R-14E should be mounted near the control panel or within cabinet space to minimize long runs of unsupervised wiring
- Test EOL circuit supervision after commissioning to confirm the panel registers proper relay status and detects simulated faults
The R-14E delivers straightforward 4-channel relay switching with the safety-critical EOL oversight that modern fire alarm integrations demand. It's a proven choice for connecting access control, door locks, and emergency systems where loss of relay function poses a life-safety risk.
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology