Vertiv Rpdu Monitored Unit Level 100A 277/480V WYE 66.4KW Horizontal (15) Anderso - VP4NC2A0

Vertiv VP4NC2A0 Monitored Horizontal Rack PDUOverviewThe VP4NC2A0 is a unit-level monitored rack PDU rated for 100A at 277/480V WYE (66.4kW), designed…

$4,780.00 $3,277.99 SAVE $1502
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Vertiv Rpdu Monitored Unit Level 100A 277/480V WYE 66.4KW Horizontal (15) Anderso - VP4NC2A0

$4,780.00
$3,277.99

Overview

SKU: VP4NC2A0
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv VP4NC2A0 Monitored Horizontal Rack PDU

Overview

The VP4NC2A0 is a unit-level monitored rack PDU rated for 100A at 277/480V WYE (66.4kW), designed for high-density data center rows and colocation cabinets where three-phase 480V WYE power distribution is the standard infrastructure. At 1U horizontal form factor (3.4 in H × 17.1 in W × 12 in D), it mounts cleanly in standard 19-inch rack horizontal positions without consuming vertical space reserved for active compute. Unit-level monitoring means you get per-PDU current and power visibility without the cost of outlet-level metering — the right tradeoff for environments where row-level capacity planning matters more than per-port granularity. The 15 Saf-D-Grid Series 400 output positions provide a safety-locking connection that prevents accidental disconnection under load — a meaningful operational detail when racking high-draw servers in live environments.

Compatibility

Designed for data center cabinets and enclosures wired for three-phase 277/480V WYE service — commonly found in purpose-built colo facilities and enterprise machine rooms with dedicated electrical infrastructure. Output is 277V, suitable for equipment with IEC or Saf-D-Grid Series 400 compatible power inputs. Pairs with Vertiv VR, VRA, and SmartCabinet rack enclosures that support horizontal PDU mounting rails. Confirm your facility's input breaker and whip connector are rated for 100A three-phase WYE before installation; the VP4NC2A0 does not include input cable or whip.

Installation Notes

Mounts horizontally in a standard 1U rack position. Unit weight is 31 lbs — factor this into rack load calculations, particularly in fully populated high-density configurations. Output connections use Saf-D-Grid Series 400 locking connectors; verify load equipment ships with or supports compatible Saf-D-Grid plugs. Input feed requires a 100A three-phase 277/480V WYE source with appropriate overcurrent protection upstream.

Specifications
Weight: 31 lbs
Height: 3.4 in
Width: 17.1 in
Depth: 12 in
Capacity: 100A
Input Voltage Range: 277/480V
Output Voltage Range: 277V
Output Options: 15 Saf-D-Grid Series 400
Location: Horizontal
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources