Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv VP4NC0A0 Monitored Unit-Level Vertical PDU

Overview

The VP4NC0A0 is a unit-level monitored vertical rack PDU rated at 100A, designed for high-density 3-phase data center deployments running 277/480V WYE power distribution. At 66.4kW capacity, it handles the power demands of modern AI-compute racks, high-density blade server bays, and dense GPU clusters that standard 208V PDUs cannot serve. The 72-inch vertical form factor installs along the rear or side of the rack without consuming a single rack unit, preserving all usable 1U slots for compute. Unit-level monitoring means you get per-PDU current and power data — enough visibility to track load balancing across the cabinet without the added cost of outlet-level instrumentation.

Compatibility

The VP4NC0A0 is engineered for facilities delivering 277/480V WYE 3-phase power — common in purpose-built enterprise and colocation data centers wired to NEC Article 647 or equivalent. The 30 outlets use the Saf-D-Grid Series 400 connector standard, which requires Saf-D-Grid–compatible server power supplies or whip adapters; standard IEC C13/C19 equipment does not plug in directly. Confirm your IT load uses Saf-D-Grid receptacle compatibility or provision the appropriate adapter whips before ordering. Pairs with Vertiv's Geist-branded monitoring infrastructure and is compatible with Vertiv's TRELLIS and Environet Alert DCIM platforms for facility-level power visibility.

Installation Notes

At 31 lbs and 72 inches in depth, the VP4NC0A0 requires two-person installation for safe vertical mounting. Input feed is a 100A 277/480V WYE branch circuit — verify your floor PDU or busway tap is rated accordingly before commissioning. Output voltage is 277V line-to-neutral; this is not a step-down transformer unit. Confirm downstream equipment is rated for 277V input. Vertical mounting orientation is fixed — this unit is not rated for horizontal deployment.

Specifications
Weight: 31 lbs
Height: 3 in
Width: 3 in
Depth: 72 in
Capacity: 100A
Input Voltage Range: 277/480V
Output Voltage Range: 277V
Output Options: 30 Saf-D-Grid Series 400
Location: Vertical
Q&A
Reviews
Have Questions?

Vertiv Rpdu Monitored Unit Level 100A 277/480V WYE 66.4KW Vertical (30) Anderson - VP4NC0A0

$5,260.00
$3,606.99

RELATED PRODUCTS

Save $1,513.01
Vertiv Rpdu Monitored Unit Level 100A 277/480V WYE 66.4KW Vertical (18) Anderson
Add to Cart The item has been added

Vertiv VP4NC0A1

Vertiv Rpdu Monitored Unit Level 100A 277/480V WYE 66.4KW Vertical (18) Anderson - VP4NC0A1

Unit-level monitored, vertical rack PDU rated at 100A and 277/480V WYE (66.4kW) — purpose-built for high-density data center rows where per-outlet

    Usually Ships in 2-3 Weeks Free shipping over $499
    $4,816.00 $3,302.99 Save $1,513.01
    The item has been added Add to quote
    $4,816.00 $3,302.99 Save $1,513.01
    Save $1,513.01 Add to cart Add to quote
    Save $1,275.01
    Vertiv Rpdu Monitored Unit Level 80A 277/480V WYE 66.4KW Vertical (30) Anderson
    Add to Cart The item has been added

    Vertiv VP4NA0A3

    Vertiv Rpdu Monitored Unit Level 80A 277/480V WYE 66.4KW Vertical (30) Anderson 2 - VP4NA0A3

    Vertically mounted, unit-level monitored rack PDU rated for 80A at 277/480V WYE (3-phase), delivering up to 66.4kW of power distribution across 30

      Usually Ships in 2-3 Weeks Free shipping over $499
      $4,060.00 $2,784.99 Save $1,275.01
      The item has been added Add to quote
      $4,060.00 $2,784.99 Save $1,275.01
      Save $1,275.01 Add to cart Add to quote
      Save $1,199.01
      Vertiv Rpdu Monitored Unit Level 80A 277/480V WYE 66.4KW Vertical (18) Anderson
      Add to Cart The item has been added

      Vertiv VP4NA0A4

      Vertiv Rpdu Monitored Unit Level 80A 277/480V WYE 66.4KW Vertical (18) Anderson 2 - VP4NA0A4

      Vertical, unit-level monitored power distribution unit rated for 80A at 277/480V WYE, delivering up to 66.4kW of monitored capacity in a single

        Usually Ships in 2-3 Weeks Free shipping over $499
        $3,816.00 $2,616.99 Save $1,199.01
        The item has been added Add to quote
        $3,816.00 $2,616.99 Save $1,199.01
        Save $1,199.01 Add to cart Add to quote
        Save $1,502.01
        Vertiv Rpdu Monitored Unit Level 100A 277/480V WYE 66.4KW Horizontal (15) Anders
        Add to Cart The item has been added

        Vertiv VP4NC2A0

        Vertiv Rpdu Monitored Unit Level 100A 277/480V WYE 66.4KW Horizontal (15) Anderso - VP4NC2A0

        Unit-level monitored rack PDU rated for 100A at 277/480V WYE (66.4kW), designed for high-density data center rows and colocation cabinets where

          Usually Ships in 2-3 Weeks Free shipping over $499
          $4,780.00 $3,277.99 Save $1,502.01
          The item has been added Add to quote
          $4,780.00 $3,277.99 Save $1,502.01
          Save $1,502.01 Add to cart Add to quote

          System Design, Deployment & Technical Support

          Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

          Fixed scope • Fixed price

          System Design Assistance

          • Get help validating product compatibility
          • Coverage requirements
          • Storage planning and deployment architecture before you buy.
          Request Design Help

          Deployment & Configuration Support

          • Access fixed-scope support for rollout planning
          • User setup guidance
          • Migration and system standardization across single-site or multi-site deployments
          View Support Services

          Guides, Tools & Calculators

          • PoE requirements
          • Storage retention
          • Camera selection and deployment methodology
          Open Technical Resources