Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv VP4NA0A4 Monitored Unit-Level Vertical PDU

Overview

The VP4NA0A4 is a vertical, unit-level monitored power distribution unit rated for 80A at 277/480V WYE, delivering up to 66.4kW of monitored capacity in a single rack-mount form factor. At 72 inches deep with a 2.5 x 3 inch cross-section, it installs vertically in standard data center cabinets where horizontal PDU real estate is limited or where high-density three-phase power distribution is required. Unit-level monitoring means you get per-PDU current and load visibility — useful in high-density compute rows where aggregate cabinet load management matters.

Compatibility

The VP4NA0A4 is designed for deployment in data center power distribution environments requiring 277/480V WYE three-phase input — typical in North American facilities running 480V infrastructure from a step-down transformer. The 18 Vertiv Saf-D-Grid Series 400 outlets are finger-safe, tool-free locking connectors suited for high-density server and network equipment installations. Saf-D-Grid Series 400 receptacles require compatible Saf-D-Grid plugs on connected equipment or power cords — verify cord sets are ordered separately with the correct Series 400 plug configuration before deployment. This unit is not compatible with standard NEMA receptacle loads without an appropriate adapter or cord set.

Installation Notes

Vertical orientation requires a standard two-post or four-post open-frame rack or enclosed server cabinet with sufficient vertical clearance for the 72-inch length. At 20 lbs, two-person installation is advisable. Input feed is 80A at 277/480V WYE — confirm your facility's branch circuit breaker and whip are sized and rated accordingly before commissioning. The 277V output voltage at each Saf-D-Grid outlet is phase-to-neutral; connected loads must be rated for 277V AC input. No NEMA-twist or IEC outlets are present — cord set compatibility planning is a prerequisite, not an afterthought.

Specifications
Weight: 20 lbs
Height: 3 in
Width: 2.5 in
Depth: 72 in
Capacity: 80A
Input Voltage Range: 277/480V
Output Voltage Range: 277V
Output Options: 18 Saf-D-Grid Series 400
Location: Vertical
Q&A
Reviews
Have Questions?

Vertiv Rpdu Monitored Unit Level 80A 277/480V WYE 66.4KW Vertical (18) Anderson 2 - VP4NA0A4

$3,816.00
$2,616.99

RELATED PRODUCTS

Save $1,275.01
Vertiv Rpdu Monitored Unit Level 80A 277/480V WYE 66.4KW Vertical (30) Anderson
Add to Cart The item has been added

Vertiv VP4NA0A3

Vertiv Rpdu Monitored Unit Level 80A 277/480V WYE 66.4KW Vertical (30) Anderson 2 - VP4NA0A3

Vertically mounted, unit-level monitored rack PDU rated for 80A at 277/480V WYE (3-phase), delivering up to 66.4kW of power distribution across 30

    Usually Ships in 2-3 Weeks Free shipping over $499
    $4,060.00 $2,784.99 Save $1,275.01
    The item has been added Add to quote
    $4,060.00 $2,784.99 Save $1,275.01
    Save $1,275.01 Add to cart Add to quote
    Save $1,513.01
    Vertiv Rpdu Monitored Unit Level 100A 277/480V WYE 66.4KW Vertical (18) Anderson
    Add to Cart The item has been added

    Vertiv VP4NC0A1

    Vertiv Rpdu Monitored Unit Level 100A 277/480V WYE 66.4KW Vertical (18) Anderson - VP4NC0A1

    Unit-level monitored, vertical rack PDU rated at 100A and 277/480V WYE (66.4kW) — purpose-built for high-density data center rows where per-outlet

      Usually Ships in 2-3 Weeks Free shipping over $499
      $4,816.00 $3,302.99 Save $1,513.01
      The item has been added Add to quote
      $4,816.00 $3,302.99 Save $1,513.01
      Save $1,513.01 Add to cart Add to quote
      Save $1,030.01
      Vertiv Rpdu Monitored Unit Level 80A 277/480V WYE 66.4KW Horizontal (15) Anderso
      Add to Cart The item has been added

      Vertiv VP4NA2A0

      Vertiv Rpdu Monitored Unit Level 80A 277/480V WYE 66.4KW Horizontal (15) Anderson - VP4NA2A0

      Unit-level monitored rack power distribution unit designed for high-density, three-phase datacenter deployments running 277/480V WYE infrastructure

        Usually Ships in 2-3 Weeks Free shipping over $499
        $3,280.00 $2,249.99 Save $1,030.01
        The item has been added Add to quote
        $3,280.00 $2,249.99 Save $1,030.01
        Save $1,030.01 Add to cart Add to quote
        Save $1,653.01
        Vertiv Rpdu Monitored Unit Level 100A 277/480V WYE 66.4KW Vertical (30) Anderson
        Add to Cart The item has been added

        Vertiv VP4NC0A0

        Vertiv Rpdu Monitored Unit Level 100A 277/480V WYE 66.4KW Vertical (30) Anderson - VP4NC0A0

        Unit-level monitored vertical rack PDU rated at 100A, designed for high-density 3-phase data center deployments running 277/480V WYE power

          Usually Ships in 2-3 Weeks Free shipping over $499
          $5,260.00 $3,606.99 Save $1,653.01
          The item has been added Add to quote
          $5,260.00 $3,606.99 Save $1,653.01
          Save $1,653.01 Add to cart Add to quote

          System Design, Deployment & Technical Support

          Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

          Fixed scope • Fixed price

          System Design Assistance

          • Get help validating product compatibility
          • Coverage requirements
          • Storage planning and deployment architecture before you buy.
          Request Design Help

          Deployment & Configuration Support

          • Access fixed-scope support for rollout planning
          • User setup guidance
          • Migration and system standardization across single-site or multi-site deployments
          View Support Services

          Guides, Tools & Calculators

          • PoE requirements
          • Storage retention
          • Camera selection and deployment methodology
          Open Technical Resources