Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The VP4NA2A0 is a unit-level monitored rack power distribution unit designed for high-density, three-phase datacenter deployments running 277/480V WYE infrastructure. At 80A input capacity and 66.4kW total load, this unit targets high-draw compute rows — GPU clusters, hyperscale blade chassis, or dense AI-compute racks where standard 208V PDUs simply can't deliver the per-rack wattage needed. The horizontal 1U form factor (3.4" H × 17.1" W × 12" D) drops cleanly into a standard 19" 1U bay, keeping U-space consumption predictable when multiple PDUs are deployed per row.
Designed for Vertiv's Saf-D-Grid Series 400 power ecosystem — the 15 Saf-D-Grid Series 400 outlets are keyed connectors specific to that family, so standard NEMA or IEC C19/C13 cords will not connect directly. Confirm that downstream load equipment is cabled with Saf-D-Grid Series 400 whips before ordering. Input feeds from a 277/480V WYE three-phase source; this unit will not operate on a 208V delta or single-phase feed. Verify your facility's PDU branch circuit is rated for 80A at 277/480V WYE before installation. Compatible with Vertiv's Avocent and Liebert infrastructure management platforms for unit-level monitored data visibility.
Horizontal rackmount orientation only — the VP4NA2A0 is not rated for vertical or toolless drop-in configurations outside a standard 19" rack bay. At 20 lbs, two-person installation is advisable during slide-in. The 12" depth fits standard 4-post racks without rear-clearance issues; verify cable management arm clearance before final seating. Input termination requires a qualified electrician: 277/480V WYE branch circuits operate at lethal voltage levels. Output voltage is 277V per outlet — confirm all attached equipment supports 277V input before energizing.