APC by Schneider Electric Rack PDU 2G Switched Zerou 30A 120/208V (16) 5-20R (7) - AP8970NRGX874

APC by Schneider Electric AP8970NRGX874 Switched Zero-U Rack PDUOverviewThe APC by Schneider Electric AP8970NRGX874 is a 2G Switched Zero-U rack power…

$2,690.00 $1,794.99 SAVE $895
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Rack PDU 2G Switched Zerou 30A 120/208V (16) 5-20R (7) - AP8970NRGX874

$2,690.00
$1,794.99

Overview

SKU: AP8970NRGX874
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric AP8970NRGX874 Switched Zero-U Rack PDU

Overview

The APC by Schneider Electric AP8970NRGX874 is a 2G Switched Zero-U rack power distribution unit rated at 30A with support for 120/208V dual-voltage environments. It provides (16) 5-20R receptacles plus (7) additional outlets, giving data center and network closet operators per-outlet switched control without consuming a rack unit of vertical space — the Zero-U form factor mounts in the side channel or rear of standard 19-inch enclosures, preserving all usable rack space for active equipment.

Switched PDUs at this amperage tier are the right choice when you need remote outlet cycling — useful for recovering locked-up devices, staggering startup loads after a power event, or enforcing scheduled power policies on specific equipment without rolling a technician to the rack. The 2G (second-generation) platform in the APC by Schneider Electric lineup includes the network management interface upgrades that allow integration with APC's EcoStruxure IT and third-party DCIM tools via SNMP and Modbus.

Key Features

  • Zero-U Form Factor: Installs in the side or rear channel of a standard rack enclosure, consuming no equipment rack units — every U stays available for servers, switches, or storage.
  • 30A / 120/208V Input: Handles the dual-voltage branch circuits common in modern data centers and IDF closets, making it compatible with both single-phase 120V and two-leg 208V distribution without a step-down transformer.
  • 16x 5-20R Receptacles: The NEMA 5-20R outlet type accepts standard 5-15P and 5-20P plugs — covers most 1U servers, network appliances, and 1U UPS units without needing plug adapters.
  • Per-Outlet Switching: Individual outlet control lets you cycle a single frozen device remotely without interrupting power to adjacent equipment — reduces truck rolls and mean time to recovery on locked network gear.
  • 2G Network Management: The second-generation management card supports SNMP v1/v2c/v3, secure web interface, and environmental monitoring expansion, integrating into network management and DCIM platforms without additional hardware.
  • Outlet-Level Metering: Per-outlet current monitoring lets you track actual load per device — useful for capacity planning, identifying overloaded circuits before they trip, and auditing power costs per tenant in colocation environments.

Integration and Compatibility

The AP8970NRGX874 integrates with APC EcoStruxure IT Gateway and Data Center Expert for centralized monitoring. SNMP MIBs are available for third-party NMS platforms including SolarWinds, PRTG, and Nagios. The unit accepts APC AP9320 environmental monitoring probes (temperature/humidity) when paired with the network management interface. Verify input plug type and branch circuit capacity — a 30A PDU requires a 30A branch circuit with the correct input connector; confirm your PDU input cord matches your PDL/PDU panel configuration before ordering.

Frequently Asked Questions

Q: What input plug does the AP8970NRGX874 use?

A: The AP8970NRGX874 is a 30A unit rated for 120/208V environments. Verify the specific input cord and plug configuration from the APC product page or contact pre-sales engineering before ordering — input connector type varies by regional configuration on this SKU.

Q: Can I control individual outlets remotely on the AP8970NRGX874?

A: Yes. As a Switched PDU, the AP8970NRGX874 supports per-outlet on/off/reboot control via the onboard network management interface, accessible through a web browser, SNMP, or command-line interface over the network.

Q: Does the AP8970NRGX874 fit in a standard 19-inch rack?

A: The AP8970NRGX874 uses a Zero-U form factor, meaning it mounts vertically in the side or rear channel of a rack enclosure rather than occupying horizontal rack units. It is designed for standard 19-inch rack enclosures but does not consume any U-space.

Q: What network protocols does the AP8970NRGX874 support?

A: The 2G management platform supports SNMP v1/v2c/v3, secure HTTPS web interface, and Modbus TCP — compatible with most enterprise NMS and DCIM platforms. Integration with APC EcoStruxure IT is native.

Q: Is the AP8970NRGX874 compatible with APC environmental sensors?

A: The 2G network management interface on this PDU series supports APC environmental monitoring accessories for temperature and humidity tracking. Confirm sensor compatibility with the specific management card version installed.

Marty Allison
Marty Allison

The AP8970NRGX874 is the configuration I reach for when a rack has mixed 120V and 208V gear and the team needs outlet-level control without sacrificing a single rack unit to the PDU — the Zero-U side-mount keeps every U available for revenue-generating equipment. The 30A branch circuit rating gives you enough headroom for a dense 1U server population without running multiple lower-amperage circuits to the same cabinet.

Technical Highlights:

  • Zero-U Mounting: No rack units consumed — in tight edge and IDF deployments where every U costs real money, this is the spec that determines whether a PDU is viable or not.
  • 16x NEMA 5-20R Outlets: Accepts both 5-15P and 5-20P plugs without adapters — covers virtually every 1U server, managed switch, and network appliance shipping today without a plug conversion kit.
  • Per-Outlet Switched Control: Remote outlet cycling over SNMP or web interface means a locked-up device gets power-cycled from the NOC, not from a site visit — in multi-site deployments this is where switched PDUs pay for themselves in the first month.

Deployment Considerations:

  • Confirm branch circuit capacity and input cord plug type before installation — a 30A PDU requires a correctly rated 30A circuit with the matching input receptacle at the panel; mismatches here delay commissioning.
  • The 2G management card requires a dedicated Ethernet drop to the PDU; plan for this in your rack cable management layout, as side-mounted Zero-U units route the management cable differently than 1U horizontal PDUs.

This unit is well-matched to data center infrastructure deployments and edge network closets where cabinet density is high, per-device remote power control is operationally required, and branch circuits are provisioned at 30A — particularly colocation environments where per-outlet metering supports tenant-level power billing.

Specifications
Mfr: AP8870
Unspsc: 39121011
Item: 0823718-
Cnet Cat Code: 10061401
Manufacturer: 77Z30AA
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources