APC by Schneider Electric
SKU: AP8958
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APC by Schneider Electric AP8959NA3 is a 2nd-generation switched rack PDU built for data center managers and IT architects who need per-outlet remote power control across mixed C13/C19 device populations. Running at 208V on a 20A circuit, it delivers 24 individually switchable outlets — (21) IEC 320 C13 and (3) IEC 320 C19 — making it a practical fit for rows of 1U servers alongside higher-draw storage arrays or network appliances that require C19 feeds.
The NEMA L6-20P input plug and 9.84-foot (3-meter) cord provide enough drop distance from a raised-floor L6-20 receptacle to reach the PDU's vertical or horizontal mount position in the cabinet without cable management strain. If you manage rack power distribution across multiple cabinets, the 2G switching generation supports per-outlet sequenced power cycling — an important distinction from basic metered-only units that require a physical touch or a full-PDU reboot to recover a locked device.
The AP8959NA3 connects to network management infrastructure via APC's embedded Network Management Card interface, enabling integration with SNMP-based monitoring platforms, APC EcoStruxure IT, and third-party DCIM tools. The switched 2G platform supports per-outlet current metering alongside switching, so power usage data flows alongside control commands — useful for capacity planning in environments tracked by a power management system.
For facilities running an APC UPS upstream, the L6-20P input aligns directly with most APC and third-party 208V UPS output receptacles. The 100–240VAC input tolerance also means this PDU functions behind a step-up/step-down transformer for international standardization. Review your rack cabinet zero-U mounting channel compatibility before ordering — vertical PDU mounting hardware requirements vary by cabinet manufacturer and rail depth.
Q: What is the actual usable load capacity of the AP8959NA3?
A: The AP8959NA3 is rated for 20A maximum input, but APC derate the continuous load to 16A — the NEC 80% continuous load rule. At 208V, that gives you a usable budget of approximately 3,328W across all 24 outlets combined.
Q: What input plug does the AP8959NA3 use?
A: It uses a NEMA L6-20P twist-lock plug on a 9.84-foot (3-meter) cord, designed for 208V branch circuits standard in North American data centers.
Q: Can the AP8959NA3 be used in a 230V facility?
A: Yes. The acceptable input voltage range is 100–240VAC, so it will operate on 230V circuits. Confirm the local plug/receptacle type matches the L6-20P or use an appropriate adapter.
Q: What is the difference between C13 and C19 outlets on the AP8959NA3?
A: C13 outlets handle devices up to roughly 10A (standard servers, switches, 1U appliances). The three C19 outlets are rated for higher-draw equipment — blade chassis PSUs, high-density storage, and infrastructure devices that ship with C20 power cords. The AP8959NA3 provides (21) C13 and (3) C19.
Q: Does the AP8959NA3 support per-outlet power monitoring?
A: The switched 2G platform includes per-outlet metering alongside switching control, enabling both remote on/off/reboot and current draw visibility per outlet through the network management interface.
Q: What are the operating temperature limits for the AP8959NA3?
A: Operating range is -5°C to 45°C (23°F to 113°F) at 5–95% relative humidity (non-condensing). Storage range extends to -25°C to 65°C.

The spec that matters most day-to-day on the AP8959NA3 is the 16A regulatory derated limit against the 20A breaker — that 4A headroom is the gap between a stable cabinet and a nuisance trip at 3 AM. I've seen integrators load these to nameplate and wonder why the breaker trips; the 16A continuous ceiling is the number to design to, not 20A.
Technical Highlights:
Deployment Considerations:
The AP8959NA3 is the right fit for a colocation cage or enterprise server row where remote power cycling is a weekly operational need, the outlet mix is genuinely split between 1U servers (C13) and higher-draw storage or blade chassis (C19), and the facility runs 208V on L6-20 branch circuits — which covers the majority of purpose-built North American data center deployments.