APC by Schneider Electric Rack PDU 2G Switched Zerou 17.2KW (60A 5PIN) 208V (42) C13 - AP8967X668

APC by Schneider Electric AP8967X668 Switched Zero-U 17.2KW Rack PDUOverviewThe APC by Schneider Electric AP8967X668 is a 2nd-generation Switched Zero…

$3,860.00 $2,509.99 SAVE $1350
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Rack PDU 2G Switched Zerou 17.2KW (60A 5PIN) 208V (42) C13 - AP8967X668

$3,860.00
$2,509.99

Overview

SKU: AP8967X668
UPC: 731304330912
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric AP8967X668 Switched Zero-U 17.2KW Rack PDU

Overview

The APC by Schneider Electric AP8967X668 is a 2nd-generation Switched Zero-U rack power distribution unit rated for 17.2KW at 208V with a 60A 5-pin input — built for high-density data center rows, network closets, and security operations centers where per-outlet switching and load visibility matter. Zero-U form factor means it mounts vertically in the rear rail channel of a standard rack, consuming none of your 1U/2U device slots. If you're running 20+ servers or a dense NVR/switch stack and need remote outlet cycling without a hands-on visit, this is the unit to evaluate. Explore the full APC by Schneider Electric power management line for matching transfer switches and UPS units.

Key Features

  • 17.2KW / 208V / 60A Input: Handles the full power budget of a densely loaded 42U rack — a single PDU can carry dual-corded servers, PoE switches, and NVR storage simultaneously without tripping branch circuits. The 5-pin 60A plug is the standard locking connector for 208V branch circuits in North American data centers, so no custom cabling is required.
  • 42 C13 Outlets (Switched): Each of the 42 IEC C13 receptacles can be individually switched on or off from the management interface. That means you can hard-cycle a hung server, stagger boot sequencing to avoid inrush current spikes, or lock out specific outlets without touching the rack — directly relevant if your rack is in a remote IDF or co-location cage.
  • Switched 2G (2nd Generation) Architecture: The 2G platform supports per-outlet current metering alongside switching, giving you visibility into which device is drawing what load in real time. Catching a failing PSU drawing 20% over spec before it trips the breaker is the kind of early warning that justifies managed PDUs over basic strips in any production environment.
  • Zero-U Vertical Mounting: No rack unit consumption. The PDU mounts in the vertical channel on the rear of a standard EIA-310 rack. For rack infrastructure planning, this keeps all 42U available for active equipment — an important consideration when space is already allocated.
  • 50.71 lb Build Weight: At just over 50 lbs, this is a two-person installation. Factor that into your rack loading calculation — most standard server racks are rated 1,000–1,500 lbs, but the PDU's own mass plus cable weight adds up in fully loaded rows. Review your power distribution planning guide before finalizing rack layout.

Integration & Compatibility

The AP8967X668 is designed for standard EIA-310 compliant racks and integrates with APC's EcoStruxure IT and Data Center Expert (DCE) platforms for centralized monitoring and alerting. The Switched 2G feature set supports SNMP, HTTPS, and SSH for integration with third-party DCIM tools and NMS platforms. IEC C13 outlets are compatible with the C14 power connectors used on the vast majority of 1U and 2U servers, switches, and storage devices. For equipment requiring C19 outlets (high-draw servers, blade chassis), review higher-amperage outlet configurations in the rack PDU category before ordering — this unit is C13 only per available evidence. Pair with an APC UPS on the same 208V branch for full runtime protection.

Frequently Asked Questions

Q: What input plug type does the AP8967X668 use?

A: The AP8967X668 uses a 60A 5-pin locking plug designed for 208V branch circuits. This is the standard North American 3-phase or high-leg delta 208V connector found in data center and commercial electrical panels.

Q: How many outlets does the AP8967X668 have, and what type are they?

A: The unit provides 42 IEC C13 switched outlets. Each outlet can be individually controlled via the management interface for remote cycling or load shedding.

Q: Does the AP8967X668 take up rack unit space?

A: No. The AP8967X668 is a Zero-U design — it mounts vertically in the rear channel of a standard EIA-310 rack, preserving all horizontal rack units for active equipment.

Q: What is the total power capacity of the AP8967X668?

A: The AP8967X668 is rated at 17.2KW at 208V with a 60A input — suitable for high-density rack deployments in data centers and security operations environments.

Q: How much does the AP8967X668 weigh?

A: The unit weighs 50.71 lbs. Plan for a two-person installation and verify your rack's load rating before mounting.

Eden Phillips
Eden Phillips

The AP8967X668 is the unit I reach for when a client is running a fully loaded 42U rack at 208V and needs outlet-level control without sending a tech on-site. That 17.2KW / 60A input headroom is the key number — it's enough to handle dual-corded servers plus PoE switches and NVR storage in a single PDU run, and the Switched 2G per-outlet metering means you're not flying blind on load distribution.

Technical Highlights:

  • 17.2KW at 208V: Covers the full power budget of a dense 42U row — no need to split load across two PDUs in most standard deployments, which simplifies cabling and branch circuit planning.
  • 42 Switched C13 Outlets: Individual outlet switching lets you hard-cycle a hung device remotely or enforce a staggered boot sequence — critical in unmanned remote IDF or co-lo environments where a truck roll costs $300+.
  • Zero-U Vertical Form Factor: Every rack unit stays available for revenue-generating equipment. In a co-location billing model where you pay per U, this distinction is real money.

Deployment Considerations:

  • At 50.71 lbs, treat this as a two-person lift — confirm your rack's vertical rail load rating before install, especially in older or third-party enclosures not rated to APC's own cabinet spec.
  • The 42 outlets are all C13 — if your load includes any C19-draw devices (blade enclosures, high-draw storage), you'll need a supplemental PDU or a different model with mixed C13/C19 outlet configuration.

The AP8967X668 is the right fit for a security operations center or co-location row running 208V where remote outlet management and load metering replace what would otherwise be scheduled on-site maintenance visits.

Specifications
Blt Item: B2MZ990
Manufacturer: APC
Mfg. Part: AP8967X668
Weight: 50.71 lbs
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources