UPS & Power Management
Showing Results for UPS & Power Management
-
Panduit
SKU: ULC024
Panduit ULC024 24V LFP Battery Card for 1 kVA UPS
$1,115.12 $920.99 Save $194.13 -
Panduit
SKU: ULC372
Panduit ULC372 72V LFP Battery Card for 3kVA UPS
$3,441.94 $2,810.99 Save $630.95 -
Panduit
SKU: UMB20K
Panduit UMB20K 3-Phase UPS Maintenance Bypass Switch
$2,358.05 $2,137.99 Save $220.06 -
-
-
-
Panduit
SKU: UVP024
Panduit UVP024 External Battery Pack for SteadySine UPS
$759.11 $629.99 Save $129.12 -
SDC
SKU: RB12V7
SDC RB12V7 12VDC Rechargeable Battery Backup
12VDC, 8A rechargeable battery backup for access control during power loss
- 12VDC/8A output sustains door strikes, readers, and keypads during mains outages.
- OSDP compatibility integrates cleanly with modern access control panels—no firmware workarounds.
- 13.56 MHz NFC support enables multi-factor auth without extra protocol converters.
$76.00 $44.99 Save $31.01 -
Speco Technologies
SKU: SXU24V
Speco Technologies SXU24V Rugged Outdoor UPS Backup KIT- 24VDC
24VDC outdoor UPS backup kit for security systems in extreme climates
- Operates from -40°F to 140°F, sustaining power in extreme outdoor climates.
- 24.3A typical output at 24VDC supports cameras, access panels, and intercoms.
- Complete kit configuration reduces field assembly time and wiring errors on install.
$4,248.90 $2,309.99 Save $1,938.91 -
Speco Technologies
SKU: SXU24VKIT
Speco Technologies SXU24VKIT Outdoor UPS Backup- Integrated Route
24V outdoor UPS with integrated router/switch for remote camera sites
- Integrated router/switch eliminates separate network appliances at remote camera sites.
- 24V backup output supports legacy analog, PoE switches, and 24VAC security equipment.
- Outdoor-rated enclosure protects electronics from rain and dust; 3-year warranty included.
$4,013.20 $3,873.99 Save $139.21 -
CyberPower
SKU: RB1270B
THE RB1270B UPS Replacement Battery Cartridge Restores Life TO Cyberpower UPS SY
In stock · Ships same business day$50.00 $49.99 Save $0.01 -
Ubiquiti
SKU: UPS-2U-US
Ubiquiti UPS-2U-US Mounting Hardware
2U rackmount UPS with 1,000W capacity and 8-min runtime at half load
- Delivers 1,000W/1.44kVA with 8-min half-load runtime to bridge short outages.
- Ethernet management port enables remote monitoring and NUT-compatible shutdown.
- UL 1778-certified, NDAA-compliant build suits regulated enterprise deployments.
$301.99 -
Ubiquiti
SKU: UPS-TOWER-US
Ubiquiti UPS-TOWER-US UniFi managed 1kVA uninterruptible power
1kVA tower UPS with managed Ethernet for UniFi network protection
- Line-interactive 600W/1kVA output sustains UniFi gear through brief outages and voltage sags.
- Built-in 100/10 Mbps Ethernet port enables remote monitoring and control via UniFi software.
- Five NEMA 5-15R outlets (2 battery-backed, 3 surge-only) cover mixed load protection needs.
$172.99 -
Valcom
SKU: VBB-1424
Valcom VBB-1424 Battery Backup Box with Batteries
AC power backup box keeps Valcom audio systems running during outages
- Battery backup with included batteries for Valcom audio systems
- Preserves system functionality during commercial AC power outage
- 31.6 lb battery box made in the United States
$478.00 $259.99 Save $218.01 -
Valcom
SKU: VP-6124-UPS
Valcom VP-6124-UPS Battery Back-Up Adapter
Battery backup for VP-6124 systems during AC power loss
- Battery backup adapter for Valcom voice systems during AC outage
- Uninterrupted paging during commercial power failures
- 3.9 lb battery backup adapter made in the United States
$359.00 $194.99 Save $164.01 -
CyberPower
SKU: 1UBRKT
Vertical Stand for 1U CyberPower UPS OR Series Steel Bracket
$16.25 $15.99 Save $0.26
UPS & Power Management
Uninterruptible power supplies and rack-mount power distribution for network and surveillance infrastructure. Online and line-interactive UPS models with SNMP management protect against outages and power quality issues.
Plan Your Deployment
- Calculate total VA/watt load from all connected networking and recording equipment
- Specify required battery runtime for graceful shutdown or ride-through
- Evaluate online vs. line-interactive topology for power quality needs
- Confirm rack-mount form factor and outlet count for your cabinet
UPS & Power Management — Engineering-Grade UPS & Power Management for Commercial Deployments
This category covers 4 working models of ups & power management sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.
What to Look For
UPS topology dictates power quality during normal operation and transfer behavior during failure. Standby (offline) units switch to battery on AC failure — cheapest, with brief transfer time acceptable for cameras and switches. Line-interactive units regulate voltage and absorb sags without going to battery, extending battery life. Double-conversion online UPS deliver clean, constantly-regenerated AC — required for sensitive analytical equipment and ideal for critical NVRs.
Runtime is a function of load (watts) and battery capacity (Wh). A 1000VA UPS at 500W load runs 5-8 minutes on internal batteries — enough for graceful shutdown but not extended operation. Extended battery packs add hours. Calculate actual runtime requirement based on average utility outage duration in your area and the device's recovery behavior on power restoration.
Form factor and outlet count drive rack-vs-tower choice and circuit-breaker sizing. Tower UPSs serve standalone NVRs or desktop workstations. 1U-4U rack UPSs serve data closets and rack-mounted equipment. Look at the input plug type (NEMA 5-15, L5-30, L6-30) and confirm the building circuit supports the UPS rating; over-large UPSs on under-sized circuits trip breakers during charging.
Network management cards (APC AP9640, Eaton X-Slot) provide SNMP monitoring, email alerts, and integration with VMS or facility management software. For critical sites, this is essential — silent UPS failure leaves you blind until the next outage exposes it. Schedule annual self-tests through the management interface and replace batteries every 3-5 years as a preventive measure.
Key Specs in This Category
| Spec | Available Options |
|---|---|
| IP Rating | IP20 |
| Connectivity | Wired |
| Power | AC/DC, PoE |
| Type | Power Supply |
Top Brands in This Category
Frequently Asked Questions
What size UPS do I need for an 8-camera NVR?
For an 8-camera NVR drawing about 100-150W and a small PoE switch at 200W, plan for a 1000-1500VA UPS to support 15-30 minutes of runtime. That covers most utility outages and gives ample time for graceful shutdown if power doesn't return. For sites with frequent or extended outages, scale to 2000VA+ with an extended battery pack.
How long does a UPS battery last?
Sealed lead-acid (SLA) UPS batteries typically last 3-5 years. Lithium-ion UPS batteries (newer, more expensive) last 8-10 years. Heat is the primary aging factor — UPSs in unconditioned closets fail batteries faster. Schedule replacement at year 3 for SLA and year 7 for lithium, regardless of self-test results; runtime degrades silently and slowly before complete failure.
Should I use a UPS or a generator for backup power?
UPSs cover seconds-to-minutes outages and bridge to generator startup. Generators cover hours-to-days outages but take 10-30 seconds to come online. For sites that need uninterrupted operation through extended outages, both are required: UPS bridges the generator startup gap and conditions generator power, generator covers the long tail. Standalone UPS without generator works for most commercial sites where occasional brief outages are acceptable.
Can one UPS power my entire camera system?
For small sites (8-16 cameras, single NVR, one switch) — yes, a single UPS works. For larger sites, distribute UPS protection across multiple smaller units rather than one large UPS. Reasons: failure isolation (one UPS battery failure doesn't take down everything), shorter cable runs from UPS to load (avoids voltage drop), and runtime calculation simplicity per zone.
What's the difference between line-interactive and online UPS?
Line-interactive UPSs run on utility power normally and switch to battery on failure. They include voltage regulation (AVR) that absorbs sags and surges without battery use. Online (double-conversion) UPSs continuously regenerate AC from battery-rectified DC — perfect output regardless of input quality. Online UPSs cost 2-3x more and are appropriate for highly sensitive loads (servers, lab equipment) or sites with very poor utility power.
Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.