Rack Power Supplies
Showing Results for Rack Power Supplies
-
Vertiv
SKU: VP7N20A2
Vertiv Rpdu Switched Outlet Level Monitoring EC 20A 120/208V WYE 5.7KW Vertical ( - VP7N20A2
In stock · Ships same business day$2,880.00 $1,974.99 Save $905.01 -
Vertiv
SKU: VP7N21A0
Vertiv Rpdu Switched Outlet Level Monitoring EC 20A 120V 1.9KW Horizontal (12) NE - VP7N21A0
In stock · Ships same business day$2,046.00 $1,402.99 Save $643.01 -
Vertiv
SKU: VP7N21A1
Vertiv Rpdu Switched Outlet Level Monitoring EC 20A 120V 1.9KW Horizontal (12) NE - VP7N21A1
In stock · Ships same business day$2,062.00 $1,413.99 Save $648.01 -
Vertiv
SKU: VP7N20A3
Vertiv Rpdu Switched Outlet Level Monitoring EC 20A 120V 1.9KW Vertical (24) NEMA - VP7N20A3
In stock · Ships same business day$2,499.00 $1,713.99 Save $785.01 -
Vertiv
SKU: VP7N21A2
Vertiv Rpdu Switched Outlet Level Monitoring EC 20A 240/415V WYE 11.5KW Horizontal - VP7N21A2
In stock · Ships same business day$2,428.00 $1,664.99 Save $763.01 -
Vertiv
SKU: VP7UV0A0
Vertiv Rpdu Switched Outlet Level Monitoring EC 22.0KW Variable Power Configuration - VP7UV0A0
In stock · Ships same business day$4,495.00 $3,082.99 Save $1,412.01 -
Vertiv
SKU: VP7UV0A2
Vertiv Rpdu Switched Outlet Level Monitoring EC 22.0KW Variable Power Configuration - VP7UV0A2
In stock · Ships same business day$5,462.00 $3,745.99 Save $1,716.01 -
Vertiv
SKU: VP7N31A2
Vertiv Rpdu Switched Outlet Level Monitoring EC 30A 120/208V WYE 8.6KW Horizontal - VP7N31A2
In stock · Ships same business day$2,473.00 $1,695.99 Save $777.01 -
Vertiv
SKU: VP7N32A2
Vertiv Rpdu Switched Outlet Level Monitoring EC 30A 120/208V WYE 8.6KW Horizontal - VP7N32A2
In stock · Ships same business day$3,652.00 $2,504.99 Save $1,147.01 -
Vertiv
SKU: VP7N30AQ
Vertiv Rpdu Switched Outlet Level Monitoring EC 30A 120/208V WYE 8.6KW Vertical ( - VP7N30AQ
In stock · Ships same business day$4,160.00 $2,852.99 Save $1,307.01 -
Vertiv
SKU: VP7N31A0
Vertiv Rpdu Switched Outlet Level Monitoring EC 30A 120V 2.8KW Horizontal (12) NE - VP7N31A0
In stock · Ships same business day$2,209.00 $1,514.99 Save $694.01 -
Vertiv
SKU: VP7N30A5
Vertiv Rpdu Switched Outlet Level Monitoring EC 30A 120V 2.8KW Vertical (24) NEMA - VP7N30A5
In stock · Ships same business day$2,735.00 $1,875.99 Save $859.01 -
Vertiv
SKU: VP7N31A1
Vertiv Rpdu Switched Outlet Level Monitoring EC 30A 208V 4.9KW Horizontal (12) CO - VP7N31A1
In stock · Ships same business day$2,283.00 $1,565.99 Save $717.01 -
Vertiv
SKU: VP7N32A0
Vertiv Rpdu Switched Outlet Level Monitoring EC 30A 208V 4.9KW Horizontal (24) CO - VP7N32A0
In stock · Ships same business day$3,432.00 $2,353.99 Save $1,078.01 -
Vertiv
SKU: VP7N30A7
Vertiv Rpdu Switched Outlet Level Monitoring EC 30A 208V 4.9KW Vertical (18) Lock - VP7N30A7
In stock · Ships same business day$2,757.00 $1,890.99 Save $866.01 -
Vertiv
SKU: VP7N30AU
Vertiv Rpdu Switched Outlet Level Monitoring EC 30A 208V 4.9KW Vertical (20) Lock - VP7N30AU
In stock · Ships same business day$3,333.00 $2,285.99 Save $1,047.01
Rack Power Supplies
Rack-mount power supplies deliver regulated DC to access control panels, CCTV head-ends, and intrusion systems from a 19-inch rack or cabinet. They provide battery backup, output supervision, and centralized distribution for multi-door or multi-camera installations.
Plan Your Deployment
- Output voltage (12/24 VDC) and total amperage at continuous load
- Rack units (1U, 2U, 3U) and depth for the cabinet
- Battery backup sizing (amp-hours) for target hold-up time
- Output count and individually fused/supervised channels
- Fire alarm interface for controlled lock release on alarm
What to Look For
Size the supply for 125% of the calculated continuous load and confirm the battery bank meets the hold-up time required by local code (commonly 4 or 24 hours). Supervised outputs report shorted or open circuits back to the panel, which is required for UL 1076 and UL 294 installations. Rack integration keeps service access at the central gear location.
Common Deployment Scenarios
Rack power supplies are standard in enterprise IDF closets, data center security rooms, and multi-door openings where copper home-runs converge on a central location. They replace scattered wall-wart or transformer-based power in larger systems.