Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VP7N20A3 is a 0U vertical switched PDU designed for high-density rack environments where outlet-level power control and real-time monitoring are non-negotiable. With 24 NEMA 5-20R outlets, a 20A/120V input on a NEMA 5-20P plug, and per-outlet switching capability, this unit gives data center and IT teams granular remote power management — eliminating the need for physical access to cycle a hung server or isolate a misbehaving load. Pair it with rack power distribution units from the broader Vertiv power management catalog for a cohesive infrastructure stack.
The VP7N20A3 supports SNMP v1, v2c, and v3 — making it compatible with virtually every DCIM platform, NMS, or infrastructure monitoring tool in commercial use today, including Vertiv's own management software. The Modbus TCP support extends compatibility to building management and facilities automation systems that wouldn't typically speak SNMP. RADIUS and TACACS+ authentication integration fits naturally into enterprise network access control frameworks already governing switches and routers. IPv6 support future-proofs the deployment for environments transitioning away from IPv4-only management planes. For teams running a UPS and power infrastructure stack, pairing this PDU with compatible monitoring software gives a unified power chain view from utility input through outlet delivery. Review the Vertiv PDU selection guide to confirm this unit's 20A/120V single-phase rating aligns with your panel and branch circuit design before ordering.
Q: How many outlets does the VP7N20A3 have, and what outlet type?
A: The VP7N20A3 has 24 NEMA 5-20R outlets, each individually switched and monitored. The input plug is NEMA 5-20P at 20A/120V.
Q: Can multiple VP7N20A3 units be managed under a single IP address?
A: Yes. The dual RJ-45 Ethernet ports support daisy-chaining, allowing multiple units to share a single IP address — reducing switch port usage and simplifying management in multi-PDU rack deployments.
Q: What network protocols does the VP7N20A3 support for integration with DCIM or NMS platforms?
A: The VP7N20A3 supports SNMP v1/v2c/v3, HTTP, HTTPS, SSH, IPv4, IPv6, DHCP, NTP, SMTP, Syslog, LDAP, RADIUS, TACACS+, RSTP, and Modbus TCP — covering integration with DCIM software, enterprise NMS tools, SIEM platforms, and building management systems.
Q: Does the VP7N20A3 monitor at the individual outlet level or only at the circuit level?
A: Outlet-level monitoring. The unit tracks current, voltage, power, and temperature per outlet — not just aggregate circuit readings — allowing precise load analysis and anomaly detection per connected device.
Q: What rack form factor does the VP7N20A3 use, and how much rack space does it consume?
A: The VP7N20A3 is a 0U vertical PDU that mounts in the rear vertical channel of a standard rack enclosure, consuming zero rack units of usable equipment space. The power cord is 3 meters (approximately 9.8 ft).
Q: Is the VP7N20A3 single-phase or three-phase?
A: Single-phase. The unit accepts 100–120V nominal input via a NEMA 5-20P plug at 20A, delivering a maximum of 1.9kW across its 24 outlets.

The VP7N20A3 is the unit I reach for when a colocation or enterprise data center team needs outlet-level switched control without giving up a single rack unit of usable space. The 0U vertical form factor is the right call for high-density deployments where every 1U counts, and the 20A/120V single-phase input at 1.9kW fits cleanly on a standard 20A branch circuit — no panel engineering surprises.
Technical Highlights:
Deployment Considerations:
This unit fits best in North American colocation, enterprise IT, or edge compute deployments where outlet-level remote power cycling, per-outlet energy metering, and directory-integrated authentication are required — and where rack real estate is at a premium. It's not the right choice for 208V three-phase high-density compute rows; for those environments, look at Vertiv's three-phase switched PDU family.