Panduit F92RPU2U2ONM004 4m OS2 LC Uniboot APC Patch Cord

Panduit F92RPU2U2ONM004 Opti-Core OS2 Single-Mode LC Uniboot APC Fiber Patch Cord The Panduit F92RPU2U2ONM004 is a 4-meter (13.1 ft) OS2 single-mode f…

$72.82 $47.99 SAVE $25

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit F92RPU2U2ONM004 4m OS2 LC Uniboot APC Patch Cord

$72.82
$47.99

Overview

SKU: F92RPU2U2ONM004
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit F92RPU2U2ONM004 Opti-Core OS2 Single-Mode LC Uniboot APC Fiber Patch Cord

The Panduit F92RPU2U2ONM004 is a 4-meter (13.1 ft) OS2 single-mode fiber optic patch cord engineered for high-density datacenter and enterprise network deployments where insertion loss budgets, polarity flexibility, and space efficiency are critical. Built on Panduit's Opti-Core platform, this duplex patch cord features LC Uniboot APC connectors on both ends, consolidating the traditional two-cable duplex design into a single compact cable body with an integrated pull-tab polarity reversal mechanism. The yellow OFNP plenum-rated jacket meets UL 910 flammability requirements for in-ceiling and vertical riser installations, while the 9/125µm OS2 fiber delivers <0.35 dB/km attenuation across 1310 nm and 1550 nm wavelengths—suitable for 10GBASE-LR, 40GBASE-LR4, 100GBASE-LR4, and emerging 400G optics over distances up to 10 km. Installers gain factory-terminated reliability, optimized insertion loss performance (<0.2 dB typical per Panduit spec), and field-reversible polarity without re-termination or adapter swaps.

Key Features

  • LC Duplex Uniboot APC Connectors: Single compact boot housing both transmit and receive fibers; integrated pull-tab mechanism allows polarity reversal in under 10 seconds without tools or connector disassembly
  • OS2 Single-Mode Fiber (9/125µm): Supports 10G/40G/100G/400G Ethernet optics over datacenter-scale distances; <0.35 dB/km attenuation at 1310 nm and 1550 nm per ITU-T G.652.D
  • Angled Physical Contact (APC) Polish: 8° endface angle reduces back reflection to <-60 dB, preventing signal degradation in high-speed coherent optics and analog RF-over-fiber applications
  • Optimized Insertion Loss: Factory testing ensures <0.2 dB typical insertion loss per connection, preserving link budget headroom for complex datacenter topologies with multiple patch points
  • Plenum-Rated OFNP Jacket: UL 910-compliant low-smoke construction for code-compliant installation in air-handling spaces, vertical risers, and horizontal cable trays without conduit
  • 4-Meter Length: Ideal for rack-to-rack interconnects within a row, cross-connects between distribution and equipment racks, or connections from wall-mounted enclosures to active gear in telecommunications rooms
  • High-Density Space Savings: Uniboot design reduces cable pathway congestion by 50% compared to traditional duplex LC cords; yellow color-coding aligns with TIA-598-D single-mode identification standards
  • Factory Pre-Terminated: Precision automated polishing and testing eliminate field termination variables; each cord ships with protective dust caps and insertion loss/return loss test documentation
  • RoHS and Global Standards Compliance: Meets ISO/IEC 11801, TIA/EIA-568-C.3, TIA-604-3 (FOCIS-3), TIA-604-10 (FOCIS-10), and EU Directive 2002/95/EC for lead-free construction

The uniboot LC connector design addresses the most persistent challenge in high-density fiber deployments: managing hundreds or thousands of duplex connections in confined equipment rack spaces. Traditional duplex LC patch cords use two separate 1.25 mm ferrules side-by-side in a clip-together boot, requiring 12.7 mm of horizontal panel space per connection and creating a tangled mass of cable pairs when scaled across 48-port or 96-port cassettes. Panduit's Opti-Core uniboot consolidates both ferrules into a single molded housing measuring just 6.9 mm wide—cutting panel footprint in half and allowing integrators to deploy twice the port density in the same rack unit. The integrated pull-tab polarity reversal mechanism is critical for correcting A-to-B versus B-to-A fiber mapping errors discovered during commissioning; rather than swapping patch cords or re-terminating, technicians pull the marked tab to slide the internal ferrule holder 180 degrees, instantly reversing transmit and receive paths. This field adaptability is especially valuable in spine-leaf datacenter architectures where structured cabling polarity schemes (Method A, B, or C per TIA-568-C.0) must align with transceiver port assignments on 40GBASE-SR4 or 100GBASE-SR4 parallel optics breakout scenarios. The APC endface polish—recognizable by the green-colored connector boots in traditional implementations, though Panduit uses a pull-boot design here—provides <-60 dB return loss versus <-50 dB for ultra-physical-contact (UPC) polish. That additional 10 dB of back-reflection suppression is non-negotiable for coherent DWDM optics, 100G PAM4 signaling, and any application where reflected light creates intersymbol interference or saturates receiver photodiodes. APC is also the mandated connector type for PON (passive optical network) deployments and fiber-to-the-antenna (FTTA) distributed antenna systems in commercial buildings.

Deployment context for this 4-meter length typically falls into three scenarios: intra-rack connections in deep cabinets (1200 mm depth) where rear-mounted fiber enclosures feed front-mounted switches; cross-rack connections within the same row, spanning one or two intermediate racks; and telecommunications room horizontal cross-connects linking wall-mounted fiber distribution panels to equipment racks positioned 3–4 meters away. The OS2 fiber type classification (per ISO/IEC 11801) guarantees <0.4 dB/km attenuation at 1310 nm and <0.3 dB/km at 1550 nm, with a cable cutoff wavelength <1260 nm to ensure true single-mode propagation across the full O-band, C-band, and L-band spectrum. This makes the F92RPU2U2ONM004 suitable for 10GBASE-LR (10 km), 40GBASE-LR4 (10 km), 100GBASE-LR4 (10 km), 100GBASE-ER4 (40 km with SMF-28 Ultra), and 400GBASE-DR4 (500 m) optics per IEEE 802.3 standards. For integrators designing multi-building campus networks or metro-area dark-fiber links, OS2 fiber provides the bandwidth-distance product needed to support future 800G and 1.6T optics without re-cabling. The plenum OFNP jacket rating is UL-certified for installation in environmental air spaces per NEC Article 770.113(B)—this includes drop ceilings used for return air, vertical shafts between floors, and horizontal cable trays in raised-floor datacenters. The low-smoke, low-flame-spread construction prevents toxic gas release during fire events, a critical life-safety requirement in occupied commercial buildings. Installers should note that plenum-rated cable typically costs 20–30% more than riser (OFNR) or general-purpose (OFN) equivalents due to the fluoropolymer jacket materials, but it eliminates the need for metallic conduit in 90% of building pathways, reducing labor and material costs for long horizontal runs.

Panduit's factory termination process uses automated fusion-polishing stations with real-time interferometric endface inspection, ensuring each connector meets <0.2 dB insertion loss and >50 dB return loss (>60 dB for APC) before the cord leaves the production line. This level of quality control is impossible to replicate in field terminations, where variables like cleave angle, epoxy cure time, hand-polishing pressure, and contamination introduce 0.3–0.8 dB of variability per connection. For a typical datacenter spine-leaf architecture with three patch cord connections per end-to-end link (server NIC → ToR switch → spine switch), the cumulative insertion loss difference between factory and field terminations can exceed 1.5 dB—enough to push 100GBASE-LR4 links beyond the IEEE 802.3ba power budget and trigger bit-error-rate degradation. The F92RPU2U2ONM004 ships with protective dust caps on both connectors and includes a serialized test report documenting insertion loss and return loss measurements at 1310 nm and 1550 nm, providing as-built documentation for customer acceptance testing and future troubleshooting. Integrators should store the test reports with project closeout documentation and verify that insertion loss values align with link budget calculations before commissioning high-speed optics. The 4-meter length, yellow jacket color (TIA-598-D compliant for OS2 single-mode), and LC connector form factor make this patch cord a direct fit for structured cabling systems designed around TIA-568-C.3 guidelines, Panduit's own Opti-Core cassette modules, and any vendor's LC-based fiber distribution hardware. The uniboot design, APC polish, and plenum rating position the F92RPU2U2ONM004 as the performance choice for high-density, high-speed enterprise and datacenter networks where installation efficiency, polarity flexibility, and long-term optical reliability are non-negotiable requirements.

Specifications
Product Type: Fiber Optic Patch Cord
Brand: Panduit
MPN: F92RPU2U2ONM004
Sub-Brand: Opti-Core
Fiber Type: OS2 Single-Mode (9/125µm)
Number of Fibers: 2 (Duplex)
Connector 1 Type: LC Duplex Uniboot APC
Connector 2 Type: LC Duplex Uniboot APC
Overall Length: 4 m (13.12 ft)
Cable Jacket Color: Yellow
Flammability Rating: Plenum (OFNP) - UL 910
Insertion Loss: Optimized (
Return Loss: >60 dB (APC)
Fiber Diameter: 9µm core / 125µm cladding
Standards Compliance: ISO/IEC 11801, TIA/EIA-568-C.3, TIA-604-3 (FOCIS-3), TIA-604-10 (FOCIS-10), RoHS Directive 2002/95/EC
Package Quantity: 1 patch cord
Carton Quantity: 10 patch cords
UPC: 61305681063
Application: Datacenter interconnects, enterprise cross-connects, telecommunications room patching, high-speed Ethernet (10G/40G/100G/400G)
Type: Fiber Optic Patch Cord
Connectivity: LC Duplex Uniboot APC
Durability: Plenum Rated (OFNP)
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources