Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit CUCGF03DPB1 Net-Contain Universal Aisle Containment Ceiling Grid Section

Overview

The Panduit CUCGF03DPB1 is a 900 mm (3-foot) ceiling grid section for the Net-Contain™ Universal Aisle Containment system — the ceiling-level component that, combined with suspended ceiling tiles, provides fire suppression continuity and thermal separation in data center hot/cold aisle deployments. At 37.91 inches wide and just 0.34 inches tall when installed, it integrates flush with standard ceiling plenum infrastructure without adding structural load or disrupting overhead cable management. If you're planning or extending a data center thermal management project, this section fits directly into the Net-Contain modular framework for controlled airflow containment.

The black PVC/vinyl construction keeps the profile lightweight and corrosion-resistant — a practical call for environments where metal components near cooling equipment can accumulate condensation over time. RoHS compliance ensures the materials meet hazardous substance restrictions, relevant for facilities with environmental procurement mandates or LEED certification requirements.

Key Features

  • 900 mm (3-foot) Modular Length: The 900 mm span lets you configure containment runs in standard rack-unit increments without field cutting. Most data center aisles are planned in 3-foot bay multiples, so this section drops in without custom fitment — saving commissioning time on initial deployment and during subsequent aisle expansions.
  • 37.91-Inch Working Width (963 mm): Covers the overhead span of a standard hot or cold aisle between cabinet rows. At nearly 38 inches, this accommodates typical 600 mm and 800 mm rack footprint aisle configurations, giving you full ceiling coverage without gaps that would defeat containment pressure differentials.
  • 0.34-Inch Profile Height: At just 8.6 mm tall, this section doesn't encroach on the plenum space above it. In tight ceiling environments — raised floor data centers with limited overhead clearance — low-profile components prevent interference with cable trays, sprinkler heads, and CRAC unit return paths.
  • PVC/Vinyl Construction: Lightweight and dimensionally stable under typical data center temperature cycling (18–27°C operating ranges). Unlike metal grid sections, PVC doesn't transmit thermal energy conductively into the plenum, which keeps the thermal boundary where it belongs — at the air gap, not the ceiling panel material.
  • RoHS-Compliant Materials: Meets Restriction of Hazardous Substances requirements. For facilities managed under EU WEEE directives, green procurement policies, or enterprise sustainability mandates, RoHS compliance is a line-item procurement check — this component clears it.
  • Net-Contain™ Universal Aisle Containment System: This section is a component of Panduit's modular universal aisle containment product family. The system is designed for hot-aisle and cold-aisle containment with compatibility across mixed-vendor cabinet environments — useful when your data floor isn't a single-vendor uniform deployment. Pair it with compatible aisle containment panels and end-of-row doors for a complete thermal envelope.
  • Package Quantity: 1 Section Per Unit: Ordered individually, so you can stage procurement to match your exact aisle run length without carrying excess inventory. For phased build-outs where aisles are added one bay at a time, this prevents over-purchasing on containment materials.

Integration and Compatibility

The CUCGF03DPB1 is a component-level part within the Panduit Net-Contain™ Universal Aisle Containment ecosystem. It is designed to work alongside ceiling-mounted grid hardware, suspended tile sections, end-of-row containment doors, and vertical panel systems from the same product family. Verify your overall aisle containment system configuration against Panduit's current Net-Contain compatibility matrix before ordering — aisle width, cabinet height, and ceiling clearance all affect which grid sections and tile types are appropriate for a given row. For integration with fire suppression systems, the ceiling grid design is specifically noted as working with suspended ceilings to support fire suppression functionality in the data center environment. Review fire code requirements with your facilities and MEP engineers before finalizing containment design, particularly in jurisdictions with strict plenum fire ratings. Browse the full Panduit aisle containment catalog to identify compatible tiles, end panels, and mounting hardware for a complete system build. If you're evaluating PoE switch infrastructure or network cabinet and enclosure configurations alongside this containment component, thermal management planning benefits from coordinating rack density targets early.

Frequently Asked Questions

Q: What is the CUCGF03DPB1 used for in a data center?

A: The CUCGF03DPB1 is a ceiling grid section for the Panduit Net-Contain™ Universal Aisle Containment system. It installs at the ceiling level above hot or cold aisles, working with suspended ceiling tiles to create a thermal separation barrier that improves CRAC unit efficiency by preventing hot and cold air mixing.

Q: What are the dimensions of the CUCGF03DPB1?

A: The section spans 900 mm (approximately 35.4 inches) in length, 963 mm (37.91 inches) in width, and is 8.6 mm (0.34 inches) tall. It is packaged as a single unit per order.

Q: What material is the CUCGF03DPB1 made from?

A: It is constructed from PVC/vinyl. This material is lightweight, dimensionally stable, and non-conductive, making it appropriate for data center plenum environments. It is also RoHS-compliant.

Q: Is the CUCGF03DPB1 compatible with fire suppression systems?

A: According to Panduit's product documentation, the Net-Contain ceiling grid section is designed to work with suspended ceilings for fire suppression in the data center. Consult your MEP engineer and local fire code authority to confirm compliance for your specific installation.

Q: Does the CUCGF03DPB1 ship as a single piece or in bulk?

A: It ships as a single section per unit (Package Quantity: 1). Order the quantity matching your aisle run length.

Q: What standards does the CUCGF03DPB1 meet?

A: The CUCGF03DPB1 is RoHS-compliant, meeting the European Union's Restriction of Hazardous Substances directive requirements.

Eden Phillips
Eden Phillips

The CUCGF03DPB1 is a detail that's easy to underspec until you're commissioning and realize your ceiling-level containment is the gap in the thermal envelope. At 37.91 inches wide and 900 mm long, this section is sized for standard aisle spans between typical 600–800 mm deep rack rows — but width and fire suppression coordination are the two things worth verifying before you commit quantities to a purchase order.

Technical Highlights:

  • 900 mm Modular Length: Aligns with standard data center bay planning in 3-foot increments. Compute your aisle run in feet, divide by 3, that's your unit count — no field cutting or custom fabrication.
  • 8.6 mm Profile Height: Low enough to avoid interference with most overhead cable tray systems and sprinkler clearance zones. If your ceiling clearance above racks is already marginal (sub-100 mm), this is the right choice over thicker panel formats.
  • PVC/Vinyl Material: Non-conductive and corrosion-resistant — practically maintenance-free in the condensation-prone zones near cooling unit return paths. RoHS compliance covers your environmental procurement checkbox without any additional documentation chase.

Deployment Considerations:

  • This section is a component part, not a standalone containment system — verify full Net-Contain™ compatibility (end-of-row doors, vertical panels, tile sections) against your specific aisle width and cabinet height before finalizing your BOM. Missing one component type leaves an air bypass that defeats the thermal investment.
  • The product documentation references compatibility with suspended ceilings for fire suppression — coordinate with your MEP engineer early. Some jurisdictions require specific plenum ratings or fire damper placements that affect how containment ceiling components are installed.

Best fit for phased data center builds where hot-aisle containment is being added to an existing mixed-vendor floor: the modular 900 mm format lets you stage procurement bay by bay rather than committing to a full-aisle material order upfront.

Specifications
Sub Brand: Net-Contain™
Color: Schwarz
Material: PVC/Vinyl
Height In: 0.34
Height Mm: 8.6
Width In: 37.91
Width Mm: 963
Product Type: Dachabschnitt
Carton Qty: 0
Package Qty: 1
Standards: RoHS-kompatibel
Upc: 61305656935
Cable Category: cabinets-thermal-management-racks-enclosures
Q&A
Reviews
Have Questions?

Panduit Net-contain Univ Aisle Containme EA

$724.03
$431.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources