Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: H000X044H2M
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 0% OFF

Panduit H000X044H2M 0.48" Heat Shrink Label

Panduit H000X044H2M PXE™ Heat Shrink Label The Panduit H000X044H2M delivers printable, heat-activated wire and cable identification for structured cab…

$429.19 $428.99 SAVE $0

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit H000X044H2M 0.48" Heat Shrink Label

$429.19
$428.99

Overview

SKU: H000X044H2M
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit H000X044H2M PXE™ Heat Shrink Label

The Panduit H000X044H2M delivers printable, heat-activated wire and cable identification for structured cabling, electrical panel builds, and field terminations where permanent labeling withstands temperature cycling and UV exposure. Designed for Panduit's MP100, MP200, and MP300 thermal-transfer printers, this 0.48-inch (12.3 mm) yellow polyolefin label shrinks to conform tightly around conductors, connectors, and terminal blocks—eliminating adhesive peel common in wrap-around tape labels. Integrators spec this for data-center patch fields, access-control door loops, and fire-alarm circuits requiring NEC 760 / UL 969 compliant permanent marking that survives pull tension and cleaning solvents.

Key Features

  • Thermal-Transfer Printable Polyolefin — accepts alphanumeric text, barcodes, and symbols from MP-series printers; no smudging or fading under handling
  • 0.48" (12.3 mm) Label Width — fits 14–10 AWG conductors, Cat6A patch cords, and small cable bundles in tight equipment racks
  • Heat-Activated Shrink — applies with standard heat gun; conforms to irregular shapes and locks in place without adhesive residue
  • High-Visibility Yellow — meets ANSI/TIA-606-C color-coding for auxiliary circuits, grounding conductors, or caution-label applications
  • RoHS Compliant — lead-free material meets EU and California environmental mandates for municipal and federal job-site specs
  • 5-Label Roll, 120-Roll Case Pack — reduces per-label cost on large projects; compatible with Panduit label dispensers for field carts

Polyolefin heat-shrink labels outperform vinyl and PVC alternatives in three critical areas: temperature range (-67°F to +275°F continuous), chemical resistance (isopropyl alcohol, diesel fuel, hydraulic fluid), and dielectric strength. The H000X044H2M's 12.3 mm pre-shrink width accommodates direct printing of 6-point type with 300-dpi clarity, then shrinks 2:1 to grip cables as small as 3 mm diameter. Unlike adhesive-backed labels that curl in hot plenums or cold outdoor J-boxes, heat-shrink labels fuse into a single layer with no edge lift. This makes them the standard for UL-listed fire-alarm panels (NFPA 72 circuit IDs), Power-over-Ethernet injector banks (voltage/polarity marking), and fiber-to-the-desk deployments where MAC moves require fast visual tracing without peeling old labels.

Field techs pair these labels with Panduit's MP300 portable printer to generate on-site IDs during after-hours cutovers—print a building/floor/room code, slide the label over a terminated RJ45 patch cord, and apply 3 seconds of heat-gun airflow for a permanent, pull-proof mark. The yellow colorway supports ANSI/TIA auxiliary-circuit identification (think card-reader Wiegand pairs, door-strike power leads, PIR sensor loops) and meets OSHA 1910.145 caution-label contrast requirements when paired with black text. Compliance-driven buyers in healthcare (HIPAA-audited server rooms), finance (SOX IT general controls), and critical infrastructure (NERC CIP labeling mandates) rely on Panduit's printable heat-shrink for audit-ready cable plants where handwritten tags and peel-and-stick labels fail inspection.

This SKU ships as a 5-label roll in a 120-roll case (600 labels total), balancing per-label economy with manageable inventory for regional integrators stocking multiple label widths and colors. The H000X044H2M cross-references competitor SKUs 18056, H000X044H2C, H100X044H2C, and MC-250-342-YL, simplifying bid-spec substitutions when project engineers call out legacy part numbers. Panduit backs the PXE label family with a manufacturer warranty and maintains UL recognition under file E60957 for plenum and riser applications—critical when AHJs red-tag installs with non-listed identification materials.

Specifications
Manufacturer: Panduit
MPN: H000X044H2M
Product Type: Heat Shrink Label
Sub-Brand: PXE™
Material: Polyolefin
Color: Yellow
Overall Width: 0.48 in (12.3 mm)
Compatible Printers: MP100, MP200, MP300
Package Quantity: 5 labels per roll
Carton Quantity: 120 rolls per carton
Total Labels per Carton: 600
Standards & Compliance: RoHS compliant
UPC: 61305678702
Cross-Reference SKUs: 18056, H000X044H2C, H100X044H2C, MC-250-342-YL
Type: Heat Shrink Label
Sub Brand: PXE™
Width In: 0.48
Width Mm: 12.3
Carton Qty: 120
Package Qty: 5
Standards: RoHS compliant
Cable Category: signs-labels-identification
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources