Server Racks & Cabinets
Sub categories
Showing Results for Server Racks & Cabinets
-
Middle Atlantic
SKU: VTF3
Middle Atlantic 3 Space (5 1/4in. ) VTF3 Vent Panel Fine Perforation Pattern
In stock · Ships same business day$45.00 $24.99 Save $20.01 -
Middle Atlantic
SKU: VTF2-CP12
Middle Atlantic 12 Piece 2 Space VTF2 Vent Panel Contractor Pack Panels in Plain Poly - VTF2-CP12
In stock · Ships same business day$392.00 $209.99 Save $182.01 -
Middle Atlantic
SKU: VTF2
Middle Atlantic 2 Space (3 1/2in. ) VTF2 Vented Panel Fine Perforation Pattern
In stock · Ships same business day$38.00 $20.99 Save $17.01 -
Middle Atlantic
SKU: VTF1-CP12
Middle Atlantic 12 Piece VTF1 Vent Panel 1 Space Contractor Pack Panels in Plain Poly - VTF1-CP12
In stock · Ships same business day$312.00 $166.99 Save $145.01 -
Middle Atlantic
SKU: VTF1
Middle Atlantic 1 Space (1 3/4IN. ) Vented Panel Fine Perforation Pattern - VTF1
In stock · Ships same business day$31.00 $16.99 Save $14.01 -
Middle Atlantic
SKU: VTB-3
Middle Atlantic 3SP Light Blocking Vent - VTB-3
In stock · Ships same business day$89.00 $47.99 Save $41.01 -
Middle Atlantic
SKU: VTB-2
Middle Atlantic 2SP Light Blocking Vent - VTB-2
In stock · Ships same business day$70.00 $36.99 Save $33.01 -
Middle Atlantic
SKU: VTB-1
Middle Atlantic 1SP Light Blocking Vent - VTB-1
In stock · Ships same business day$47.00 $24.99 Save $22.01 -
Middle Atlantic
SKU: VT4
Middle Atlantic 4SP Perforated Vent Panel - VT4
In stock · Ships same business day$48.00 $25.99 Save $22.01 -
Middle Atlantic
SKU: VT3
Middle Atlantic 3 Space (5.25IN. ) Slotted Vent Perforated - VT3
In stock · Ships same business day$45.00 $23.99 Save $21.01 -
Middle Atlantic
SKU: VT1-CP12
Middle Atlantic 12 Piece VT1 Contractor Pack Vent Panel - VT1-CP12
In stock · Ships same business day$312.00 $165.99 Save $146.01 -
Middle Atlantic
SKU: VSDR-8
Middle Atlantic 8SP Vented Splt Security - VSDR-8
In stock · Ships same business day$283.00 $151.99 Save $131.01 -
Middle Atlantic
SKU: VRK-44-42HLRD
Middle Atlantic 44 Space 42IN. Deep Videorack Horizontal LRD - VRK-44-42HLRD
In stock · Ships same business day$3,709.00 $1,952.99 Save $1,756.01 -
Middle Atlantic
SKU: VRK-44-36HLRD
Middle Atlantic 44SP/36D Video Rack LRD - VRK-44-36HLRD
In stock · Ships same business day$3,642.00 $1,908.99 Save $1,733.01 -
Middle Atlantic
SKU: VPM-6
Middle Atlantic 6 Space Vertical Panel Mount - VPM-6
In stock · Ships same business day$229.00 $117.99 Save $111.01 -
Middle Atlantic
SKU: VMRK-54LRD
Middle Atlantic 54SP/31D Multibay RK LRD - VMRK-54LRD
In stock · Ships same business day$4,737.00 $2,524.99 Save $2,212.01
Server racks and cabinets are the structural foundation of any datacenter, MDF, IDF, or surveillance head-end. The right enclosure determines weight rating, airflow path, cable density, and how cleanly equipment is serviceable five years from now. Whether you're consolidating NVRs into a security closet, building an AV rack for a stadium control room, or standing up a 42U colocation cabinet, the chassis decision sets the ceiling for everything that mounts inside it.
Brands and product lines we stock
Middle Atlantic dominates the AV and security integrator space — MRK and BGR enclosed series for finished spaces, ERK open frames for service-side accessibility, and the SNE outdoor series for harsh environments. APC NetShelter SX and AR3100 cabinets are the datacenter workhorses with vendor-neutral cable management, perforated front and rear doors, and split-rear-door options for high-density deployments. Vertiv server racks cover seismic Zone 4, raised-floor, and hot-aisle/cold-aisle containment requirements.
What to consider when buying
- Static and dynamic weight load — fully loaded NVR + UPS + battery stack can exceed 2,500 lbs. Match the rated capacity, not the marketing number.
- U-height and usable depth — measure from front rail to rear rail, accounting for PDU and cable manager intrusion. Deep servers need 42 inch depth minimum.
- NEMA enclosure rating — NEMA 12 for dusty industrial, NEMA 4 for washdown, IP54 for outdoor mounting.
- Cable management integration — vertical PDU channels, side-panel D-rings, and rear cable basket compatibility.
- Airflow and ventilation — perforation percentage; front and rear doors should hit 65 percent open area minimum for hot-aisle deployments.
- Seismic certification — Zone 4 / GR-63-CORE / Telcordia compliance for west coast and telecom rooms.
- Lock and access control — keyed alike, combo, or electronic handle integration.
For high-density AI cluster builds and hot-aisle containment, see our cable management and Power & UPS selections. Working integrators on the Senior Specialist team can spec a full rack BOM including rails, PDUs, cable managers, and seismic anchoring — datacenter-grade builds with direct manufacturer sourcing.

